iEM3100 / iEM3200 / iEM3300 series
DOCA0005EN-0404/2014
Page
2014 Schneider Electric. All rights reserved
DANGER
Notices
FCC Part 15 notice
Document scope
About the book
Related documents
Validity note
Contents
Chapter
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Chapter 1 Safety precautions
DANGER
UNINTENDED OPERATION
Safety precautions
DOCA0005EN-04
What is in this chapter?
Chapter
Overview
Overview of meter functions
125 A meters
1 A / 5 A meters
iEM32 series
Typical applications
iEM31 and iEM33 series
Typical applications
Overview
DOCA0005EN-04
Dimensions
Chapter 3 Hardware and installation
What is in this chapter?
Hardware overview
All meters Meter sealing points
DOCA0005EN-04
Hardware and installation
DOCA0005EN-04
DOCA0005EN-04
Hardware and installation
DOCA0005EN-04
DOCA0005EN-04
Mounting the meter on a DIN rail
DANGER
DIN rail mounting and dismounting
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Dismounting the meter from a DIN rail
DOCA0005EN-04
Digital input wiring iEM3115 / iEM3215
Input, output and communications wiring
Pulse output wiring iEM3110 / iEM3210 / iEM3310
DANGER
The digital output is polarity-independent
Voltage input protection
Power system wiring
DANGER
Current input protection for 1 A and 5 A meters
Related topics
63 A direct measurement meter wiring
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
DANGER
125 A direct measurement meter wiring
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
DANGER
Single-phasesystems with CTs
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
indicates wiring for a balanced system
Three-phasesystems with CTs
250 mA fuses and disconnect switch Shorting block
Hardware and installation
DOCA0005EN-04
Three-phasesystems with CTs and VTs
Hardware and installation
V1 V2 V3Vn
Hardware and installation
DOCA0005EN-04
What is in this chapter?
Chapter 4 Front panel display and meter setup
1234.5
Overview
Data display screens
Example navigating the display screens
Related topics
Related topics
Data display screens iEM3150 / iEM3250 / iEM3350
Related topics
DOCA0005EN-04
Resetting accumulated energy using the display
Resets
Multi Tariff feature
Related topics
The device clock
Clock behavior on power interruption
Meter status information
Related topics
Setting the clock initially
00500
Device configuration
Entering configuration mode
Modifying parameters
Com. Protection setting
Example Configuring a list value
Related topics
Example configuring a numeric value
Configuration mode menus
Canceling an entry
Related topics
Parameter
Front panel display and meter setup
Section
Options
Front panel display and meter setup
Configuration menu for iEM3150 / iEM3350
DOCA0005EN-04
Front panel display and meter setup
DOCA0005EN-04
Front panel display and meter setup
DOCA0005EN-04
Front panel display and meter setup
DOCA0005EN-04
Front panel display and meter setup
Configuration menus for iEM3250
DOCA0005EN-04
AiEM3235 / iEM3255 / iEM3265 BiEM3255 CiEM3235
Front panel display and meter setup
DOCA0005EN-04
DiEM3265
Front panel display and meter setup
DOCA0005EN-04
Front panel display and meter setup
DOCA0005EN-04
Front panel display and meter setup
DOCA0005EN-04
Modbus communication overview
Chapter 5 Communications via Modbus RS-485
What is in this chapter?
Related topics
Table format
Modbus functions
Function list
Unit table
Command request
Command interface
Command interface overview
Command result
Set Wiring
Command list
Set Date/Time
Set Tariff iEM3155 / iEM3255 / iEM3355
Set Pulse Output iEM3155 / iEM3255 / iEM3355
DOCA0005EN-04
Communications Setup
Input Metering Setup iEM3155 / iEM3255 / iEM3355
Overload Alarm Setup iEM3155 / iEM3255 / iEM3355
DOCA0005EN-04
Modbus register list
Meter Setup and Status
Reset Partial Energy Counters
System
Communication
Command Interface
Input Metering Setup iEM3155 / iEM3255 / iEM3355
Communications via Modbus RS-485
Digital Output iEM3155 / iEM3255 / iEM3355
Digital Input iEM3155 / iEM3255 / iEM3355
Meter Data
Energy, energy by tariff and input metering
Overload Alarm iEM3155 / iEM3255 / iEM3355
Read Device Identification
The Read Device ID codes 01 and 04 are supported
Red service LED
Chapter 6 Communications via LonWorks
What is in this chapter?
LonWorks communications overview
Related topics
Location of the service pin and Neuron ID
Related topics
General variables
Related topics
Energy and energy by tariff measurements
Related topics
Related topics
Instantaneous RMS measurements
Communications via LonWorks
DOCA0005EN-04
Basic information and meter configuration
Communications via LonWorks
Network variable label
Date/time setup
Meter configuration properties
Resets
Related topics
Function profile
DOCA0005EN-04
Function profile
Struct Members
Struct Members
DOCA0005EN-04
Function profile
Function profile
Installing and registering the LonMaker plug-in
Related topics
Related topics
Browsing the meter using the LonMaker plug-in
LonMaker plug-ininterface
Page
Communications via LonWorks
DOCA0005EN-04
Configuring basic communications settings
Chapter 7 Communications via M-Bus
What is in this chapter?
M-Buscommunications overview
M-Busprotocol implementation
Communications LED indicator for M-Busmeters
M-Busprotocol support
Related topics
Data record header information
Variable data structure telegram information
Fixed data header
Data formats used by the meter DIF bits
Communications via M-Bus
Manufacturer-specificVIFE codes
DOCA0005EN-04
Related topics
Telegram information for data records
Meter information
Energy and energy by tariff measurements
Meter status information
Instantaneous measurements
Date and time information
Communications via M-Bus
Power system configuration information
Digital input and output status information
DOCA0005EN-04
Supported VIFE codes for meter configuration
Telegram information for meter configuration
Alarm status information
Related topics
Power system setup
Date/time setup
Multi Tariff setup
Digital output setup
Communications setup
Digital input setup
Overload alarm setup and acknowledgment
Resets
Installing the M-Bustool
Accessing the meter using the tool
INACCURATE DEVICE SETTINGS
Viewing meter data using the M-Bustool
Communications via M-Bus
Configuring the meter using the M-Bustool
DOCA0005EN-04
Communications via M-Bus
DOCA0005EN-04
BACnet communications overview
Chapter 8 Communications via BACnet
What is in this chapter?
BACnet protocol support
BACnet communications implementation
Configuring basic communication parameters
Related topics
Change of Value COV subscriptions
Communications LED indicator for BACnet meters
BACnet object and property information
Related topics
Analog Input objects
Related topics
Energy and energy by tariff measurements
Meter information
Instantaneous RMS measurements
DOCA0005EN-04
Related topics
Communications settings information
Digital input and output setting information
Communications via BACnet
Communications via BACnet
Analog Value object
Binary Input objects
DOCA0005EN-04
Communications via BACnet
DOCA0005EN-04
What is in this chapter?
Specifications
Electrical characteristics
Chapter
Characteristic
Power system inputs iEM32 meters
Characteristic
Inputs and outputs
Measurement accuracy
Mechanical characteristics
Environmental characteristics
Front panel
Modbus communications
Specifications
Internal clock
LonWorks communications
Related topics
M-Buscommunications
BACnet communications
Related topics
Specifications
DOCA0005EN-04
Related topics
Chapter 10 Troubleshooting
Diagnosis screen
RISK OF DAMAGE TO THE METER
Support
Diagnostic codes
Diagnostic code1
DOCA0005EN-04
Quadrant
Chapter 11 Power, energy and power factor
What is in this chapter?
Quadrant
Current phase shift from voltage
Power factor PF
True PF and displacement PF
PF lead / lag convention
PF sign in IEC
Power and PF lead / lag
PF lead / lag summary
Quadrant
PF value
Power factor register format
PF register
PF range
Related topics
Quadrant
PF formula
Power, energy and power factor
DOCA0005EN-04
Page
Schneider Electric 35, rue Joseph Monier CS30323