Overview

 

iEM3100 / iEM3200 / iEM3300 series user manual

 

 

 

 

 

 

 

 

Functions

Advantages

Applications

Meter

 

 

 

 

M-Bus communications

Communicate advanced parameters using

M-Bus network integration

iEM3135 / iEM3235 /

M-Bus protocol

iEM3335

 

 

 

Communicate advanced parameters using Modbus

 

iEM3150 / iEM3155

Modbus communications

Modbus network integration

iEM3250 / iEM3255

protocol

 

 

iEM3350 / iEM3355

 

 

 

 

 

 

 

BACnet communications

Communicate advanced parameters using BACnet

BACnet network integration

iEM3165 / iEM3265 /

MS/TP protocol

iEM3365

 

 

LonWorks communications

Communicate advanced parameters using LonWorks

LonWorks network integration

iEM3175 / iEM3275 /

 

communications

 

iEM3375

 

Identification of imported and exported active and

Ideal for facilities with back-up generators or

 

Four quadrant calculation

reactive energy allows you to monitor energy flow in

 

green power capabilities (for example, solar

 

both directions: delivered from the utility and

 

 

panels or wind turbines)

 

 

produced on-site

 

 

 

 

 

 

 

iEM3135 / iEM3155 /

 

 

Manage energy consumption and make

Measurement of active, reactive

Allows you to monitor energy consumption and

informed investment to reduce your energy bill

iEM3165/ iEM3175

and apparent energy.

production

or penalties (for example, installing capacitor

iEM3235 / iEM3255 /

 

 

banks)

iEM3265 / iEM3275

 

Can be programmed to:

This allows for monitoring of:

iEM3335 / iEM3355 /

 

Count pulses from other meters (gas, water, etc.)

WAGES

iEM3365 / iEM3375

 

 

Programmable digital input

Monitor an external status

Intrusion (for example, doors opening) or

 

 

Reset the partial energy accumulation and start a

equipment status

 

 

 

 

 

new period of accumulation

Energy usage

 

 

 

 

 

 

Can be programmed to:

This allows you to:

iEM3135 / iEM3155 /

 

Collect pulses from the meter with a Smartlink

iEM3165

 

be an active energy (kWh) pulse output, with a

 

 

Programmable digital output

system, PLC or any basic acquisition system

iEM3235 / iEM3255 /

configurable pulse weight

Monitor power levels at a detailed level and to

iEM3265

 

Alarm on a power overload at a configurable pickup

 

 

 

help detect an overload before the circuit

iEM3335 / iEM3355 /

 

setpoint

 

breaker trips

iEM3365

 

 

14

DOCA0005EN-04

Page 14
Image 14
Schneider Electric iEM3100, iEM3300, iEM3200 user manual Overview