Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 Dimensions Drawing No E1058-A

Page 23

HOT AIR

EXHAUST

TAILPIPE

LOCATION

25.4

A

469.8

526.2 516.2 495 TYP. TYP.

Generac497.4

Power®

Systems, Inc

.

821.2

469

195.8

233.2

45˚

344.6 305.9

70.8

95.5

57

TYP.

183.5

3/8"-16 WELDNUTS

(8 PLACES)

 

226.5

545

FRONT

574.7

834.9

855.8

QUIETPACT 55G

FRONT DOOR ACCESS FOR

ALL REQUIRED MAINTENANCE

VIEW FROM TOP

54

TYP.

 

 

NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS

AIR INTAKE

564.1

MUST BE KEPT CLEAR OF ANY OBSTRUCTIONS. ALL

536.2

OPEN AREA IS REQUIRED FOR COOLING.

 

 

 

FUEL INLET

90

126.2

190.4

120.5

AC OUTPUT

HARNESS

FUEL INLET

84

212REMOTE PANEL CONNECTOR

50

39.8

TYP.

 

BATTERY

 

CONNECTIONS

89.4

FUEL FILTER

 

470

 

513.7

Figure 5.2

 

- Major Features

QUIETPACT

and Dimensions (Drawing No. 0E1058-A)

55, 65, and 75 Recreational Vehicle Generators

Section 5 – General Information

21

Image 23
Contents This manual should remain with the unit Introduction Authorized Service Dealer LocationTable of Contents General Hazards Electrical Hazards Reference Number Identification Generator IdentificationGenerator AC Connection System InstallationSafety Generator ApplicabilityFuel Requirements Gasoline Specifications1.1 Fuel Consumption gph/lbs.ph Generator Control Panel Before Starting the Engine Optional Remote START/STOP PanelAutomatic Choke Letting the Engine Stabilize Starting the GeneratorStopping the Generator Field Boost High Temperature SwitchLOW OIL Pressure Switch Protection Systems5 25-HOUR BREAK-IN Period Checking the Engine OIL LevelOvervoltage Protection 6 25-HOUR CHECK-UPChanging the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR CleanerCleaning the Foam Precleaner Checking the Engine Spark Plug Clean Spark ArrestorEvery SIX Months Cleaning the GeneratorBattery Maintenance WeeklyExercising the Generator OUT of Service ProcedureRV Generator Service Interval Drive BeltQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Generator Engine Operating Speed Purpose and Scope Installation InstructionsStandards Booklets Equipment DescriptionDimensions Drawing No E1058-A Generator Location Location and SupportGenerator Restraint Generator CompartmentsSuspended Mounting Compartment SizeTypical Compartment Construction Sound Insulating MaterialsGenerator Airflow Cooling and Ventilating AIRAcoustics Compartment Floor CutoutsGasoline Fuel System Testing the InstallationParts not Included in Fuel System LP GAS Fuel SystemGenerator Fuel Supply Line Gaseous Carburetion Primary RegulatorSome Important Considerations Vapor WithdrawalExcess Flow Valve Exhaust SystemFuel Supply Lines Leakage TestsElectrical Junction BOX Exhaust System SafetyElectrical Connections Mufflers and Spark ArrestorsGenerator AC Connections WiringIsolating Different Power Sources Power Supply CordBattery Cable Connections Battery InstallationRecommended Battery Battery Cables18 Transfer Switch Isolation Method Initial Start Optional AccessoriesPost Installation Tests Before Initial START-UPInstallation Checklist Testing Under LoadProblem Cause Correction Troubleshooting GuideQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.