York R-410A manual ZF Unit Dimensions Front View, Utilities Entry

Models: R-410A

1 104
Download 104 pages 7.39 Kb
Page 99
Image 99
ZF Unit Dimensions Front View

251934-YTG-G-0708

ZF Unit Dimensions Front View

BLOWER ACCESS

 

(Location Of

FIELD-SUPPLIED

BLOWER MOTOR ACCESS Optional VFD)

DISCONNECT SWITCH

(Location Of Optional

LOCATION

VFD Bypass)

 

BLOWER

 

COMPARTMENT

 

ACCESS

 

(Auxiliary)

 

DOT PLUG

 

(For pressure

 

Drop Reading)

 

ELECTRIC

 

GAS HEAT

 

ACCESS

 

ECONOMIZER / MOTORIZED DAMPER, FIXED OUTDOOR INTAKE AIR AND POWER EXHAUST RAIN HOODS

(See detail "Y")

COMPRESSOR ACCESS (See detail "X")

OPTIONAL COIL

GUARD KIT

48-5/8" (15 Ton)

52-5/8" (17.5 thru 25 Ton)

VENT AIR OUTLET HOODS

21"

CONDENSER COILS

COMBUSTION

AIR INLET

HOOD

(C)

GAS SUPPLY ENTRY

 

 

 

 

on)

 

 

 

 

T

 

 

 

(15 .

 

 

 

 

(17

5

Ton)

-1/4"

 

 

125

-1/4"

 

25

6-3/8"

 

thru

 

 

136

 

 

 

 

 

CONTROL BOX

ACCESS 35"

5"

7-1/8"

9-3/4"

5-7/8" FRONT

46-5/8"

92"

11-1/2"

BOTTOM SUPPLY

All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request.

(A)

CONTROL WIRING ENTRY

(B)

POWER WIRING ENTRY

FRONT

VIEW

 

 

(15

Ton)

 

 

 

.5

 

-1/4"

 

(17

Ton)

RETURN

 

 

 

 

AIR

24

-1/4"

 

25

 

 

35

thru

 

 

33"

 

 

 

 

 

 

SUPPLY

AIR

2-3/4"Manual background 21-1/2"

11-1/8"

AND RETURN AIR OPENINGS (See Note)

3-3/4"

RETURN AIR

SUPPLY AIR

OUTDOOR AIR

OUTDOOR AIR (Economizer)

UNIT BASE WITH RAILS

 

 

 

 

 

 

 

Shown separately to illustrate

(D)

 

 

 

 

 

Bottom Duct openings, Power

GAS SUPPLY

 

 

 

 

 

and Gas Piping Connection

ENTRY

 

 

 

 

 

locations

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

46-5/8"

 

 

 

 

For curb mounted units, refer to the curb hanger

 

 

9-1/4"

 

 

 

dimensions of the curb for the proper size of the

 

 

 

 

12-1/2"

 

supply and return air duct connections.

 

 

 

 

 

 

 

 

(B)

POWER WIRING ENTRY

(A)

8-1/8"CONTROL WIRING ENTRY

9-3/4"

Utilities Entry

Hole

Opening Size

Used For

 

Diameter

 

 

 

 

 

A

1-1/8” KO

Control Wiring

 

Front

3/4” NPS (Fem.)

 

Bottom

 

 

 

B

3-5/8” KO

Power Wiring

 

Front

3” NPS (Fem.)

 

Bottom

 

 

 

C

2-3/8” KO

Gas Piping

(Front)1

D

1-11/16” Hole

Gas Piping (Bottom)1,2

1.One-inch Gas Piping NPT Required.

2.Opening in the bottom to the unit can be located by the slice in the

insulation.

NOTE: All entry holes should be field sealed to prevent rain water entry into the building.

Johnson Controls Unitary Products

99

Page 99
Image 99
York R-410A manual ZF Unit Dimensions Front View, Utilities Entry