ZF180-300 Side Duct Application

251934-YTG-G-0708

ZF180-300 Side Duct Application

ZF180 (15 Ton) Side Duct

Air Flow

 

 

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

 

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

(CFM)

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

 

Standard 5

HP & Field

 

Standard 5 HP & Drive

 

 

 

 

 

 

High Static 5

HP & Drive

 

 

 

 

 

 

 

Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4400

760

1.56

798

1.90

835

2.20

878

2.47

950

2.81

1014

3.11

1069

3.38

1115

3.61

1154

3.81

1184

3.97

1205

4.09

1218

4.18

4800

786

1.93

824

2.27

861

2.57

904

2.84

976

3.18

1040

3.48

1095

3.75

1142

3.98

1180

4.18

1210

4.34

1231

4.46

1244

4.55

5200

815

2.34

853

2.68

890

2.98

933

3.25

1005

3.59

1068

3.89

1123

4.16

1170

4.39

1208

4.59

1238

4.75

1260

4.87

1273

4.96

5600

845

2.79

883

3.13

920

3.43

963

3.70

1035

4.04

1099

4.34

1154

4.61

1200

4.84

1239

5.04

1269

5.20

1290

5.32

1303

5.41

6000

877

3.28

915

3.62

952

3.92

995

4.19

1067

4.53

1131

4.83

1186

5.10

1232

5.33

1271

5.53

1301

-

-

-

-

-

6400

911

3.81

949

4.15

986

4.45

1029

4.72

1101

5.06

1164

5.36

1219

5.63

-

-

-

-

-

-

-

-

-

-

6800

946

4.38

984

4.72

1021

5.02

1064

5.29

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

7200

982

4.98

1020

5.32

1057

5.62

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 HP & Field Supplied Drive

 

 

 

 

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.838.

ZF210 (17.5 Ton) Side Duct

Air Flow

 

 

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

 

 

 

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

 

2.2

2.4

2.6

(CFM)

 

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

RPM BHP

RPM BHP

RPM BHP

 

 

 

Standard 5

HP & Field Supplied Drive

 

 

 

Standard 5 HP & Drive

 

 

 

 

 

High Static 7.5 HP & Drive

 

 

4400

636

0.65

672

1.14

709

1.60

745

2.03

780

2.43

815

2.78

849

3.09

882

3.35

914

3.55

 

944

3.70

973

3.78

999

3.79

4800

649

0.99

685

1.48

721

1.94

757

2.37

793

2.77

828

3.12

862

3.43

895

3.69

927

3.89

 

957

4.04

985

4.12

1012

4.13

5200

663

1.34

700

1.83

736

2.29

772

2.72

808

3.11

843

3.47

877

3.78

910

4.04

942

4.24

 

972

4.39

1000

4.47

1027

4.48

5600

680

1.71

717

2.20

753

2.66

789

3.09

825

3.48

860

3.84

894

4.15

927

4.41

959

4.61

 

989

4.76

1017

4.84

1044

4.85

6000

699

2.11

735

2.60

772

3.06

808

3.49

844

3.88

879

4.24

913

4.55

946

4.80

977

5.01

 

1007

5.15

1036

5.24

1062

5.25

6400

719

2.55

756

3.03

792

3.49

828

3.92

864

4.32

899

4.67

933

4.98

966

5.24

998

5.45

 

1028

5.59

1056

5.67

1083

5.68

6800

742

3.02

778

3.51

814

3.97

850

4.40

886

4.79

921

5.15

955

5.46

988

5.72

1020

5.92

 

1050

6.07

1078

6.15

1105

6.16

7200

765

3.54

802

4.03

838

4.49

874

4.92

910

5.32

945

5.67

979

5.98

1012

6.24

1044

6.44

 

1074

6.59

1102

6.67

1129

6.68

7600

790

4.11

827

4.60

863

5.06

899

5.49

935

5.88

970

6.24

1004

6.55

1037

6.81

1069

7.01

 

1099

7.16

1127

7.24

1154

7.25

8000

817

4.72

853

5.21

890

5.67

926

6.10

962

6.50

997

6.85

1031

7.16

1064

7.42

1095

7.62

 

1125

7.77

1154

7.85

1180

7.86

8400

845

5.38

881

5.87

918

6.33

954

6.76

990

7.16

1025

7.51

1059

7.82

1092

8.08

1123

8.28

 

1153

8.43

1182

8.51

1208

8.52

8800

874

6.09

911

6.58

947

7.04

983

7.47

1019

7.86

1054

8.22

1088

8.53

-

-

-

-

 

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Static 7.5 HP &

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Supplied Drive

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.838.