A
For | 13” H x 6” W x 7” D |
For 7.5 thru | 13” H x 8” W x 8” D |
If the drive will not fit in the allotted space, then it will have to be mounted elsewhere; either within the building on a perpendicular wall which is not subjected to excessive temperature, vibration, humidity, dust, corrosive gas, explosive gas, etc., or within an appropriate enclosure rated for outside installation to safeguard against moisture, dust and excessive heat.
A terminal block located in the control box is provided for field connection of the VFD controls.
•Hot Gas Bypass - To allow for low cooling load operation, a
•Filter Options - Standard units are shipped with 2" throw- away filters installed. 2" pleated and 4" pleated filters are offered as a factory installed option.
•Convenience Outlet - This 110 volt outlet can be "powered" by the unit with a stepdown transformer or you may order the unit with a
•Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only.
•Double Wall Construction - Optional double wall construction is available to provide smooth inner surfaces for easy and effective cleaning to reduce risk of dirt and bacterial accumulation. Fiberglass insulation is sandwiched between heavy gauge steel sheets to form a durable, rigid casing to withstand higher working pressures and impact forces. The
•York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone, change- over bypass and VAV systems.
•Smoke Detectors - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment.
Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during “off” times due to out side air infiltration. these smoke detectors have an operational limit of 32°F to 131°F. smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms.
•Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit.
•Stainless Steel Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly.
•Stainless Steel Drain Pan - An optional rustproof stainless steel drain pan is available to provide years of
•Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an
•High Static Drive - May include a belt, blower pulley, motor pulley or a motor change to enhance blower performance.
•Low Static Drive - May include a belt, blower pulley, motor pulley or a motor change when standard airflow is not required. (ZJ/ZR/ZF300 only).
•Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory.
•Hinged Filter Door/"Tool Free" Blower And Access Panels (Not Hinged) - This option allows for easy access and maintenance.
NOTE: Knobs are shipped separately within the unit to prevent shipping damage. These must be field installed for tool free operation.
•Hinged/"Tool Free" Blower, Blower Motor, Filter And Electric Access Panels - This option allows for complete hinged and tool free access to the unit’s blower, blower motor, filters and electrical panel sections.
Control Options
•BAS - Building Automation System Controls (available on