Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 owner manual Standards Booklets

Page 22

Section 5 – General Information

QUIETPACT 55, 65, and 75 Recreational Vehicle Generators

5.1PURPOSE AND SCOPE OF THE

INSTALLATION INSTRUCTIONS

These Installation Instructions have been prepared especially for the purpose of familiarizing installers and owners of the applicable equipment with the product's installation requirements. Give serious consideration to all information and instructions in the manual, both for safety and for continued reliable operation of the equipment.

Because of the different recreational vehicle models and the variations between the models, it would be extremely difficult, if not impractical, to provide detailed instructions for every possible installation. For that reason, instructions and illustrations in this manual are general in nature. Illustrations are not intended to serve as detailed installation blueprints.

The installation should comply strictly with all applicable codes, standards and regulations pertain- ing to the installation and use of this product. If any portion of this manual appears to be in conflict with such codes, standards or regulations, the applicable codes, standards or regulations must take prece- dence over the manual.

5.2SAFETY

Before handling, installing, operating or servicing this equipment, carefully read the “Notice to Installer” and “Safety Rules” on Pages 18 and 19. Comply with all safety rules to prevent death, personal injury or damage to equipment and/or property. Stress safety to all installers, operators and service technicians who work on this equipment.

5.3STANDARDS BOOKLETS

Installation, use and servicing of this equipment should comply strictly with published standards, as well as the manufacturer's recommendations. The following standards booklets (latest revision) are available from the sources indicated:

1.NFPA Standard 501C, “Standard for Recreational Vehicles,” available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

2.NFPA 70, “NFPA Handbook of the National Electric Code,” available same as Item 1.

3.ANSI C1-1975 and ANSI 119.2-1975, available from the American National Standards Institute, 1430 Broadway, New York, NY 10018.

4.ANSI A119.2/NFPA 501C, available from the Recreational Vehicle Association, 1896 Preston White Drive, Reston, VA 22090.

5.California Administrative Code, Title 25, avail- able from the State of California, Documents Section, P.O. Box 1015, North Highlands, CA 95660.

6.CSA Electrical Bulletin 946, available from the Canadian Standards Association, Housing and Constructions Materials Section, 178 Rexdale Boulevard, Rexdale, Ontario, Canada, M9W 1R3.

5.4EQUIPMENT DESCRIPTION

Instructions and information in this section pertain to Generac air-cooled generators. These generators are designed specifically for installing in recreational vehicles. They operate 120-volt, single-phase, 60- Hertz, AC electrical loads.

5.5GENERATOR ENGINE

OPERATING SPEED

The generator’s revolving field (rotor) is driven by a single-cylinder, four-cycle engine through a pulley and drive belt arrangement. The generator supplies 120 volts AC at 60 Hertz when the rotor is operating at 3,600 rpm.The drive belt arrangement allows the engine to operate at a lower speed than the rotor.

5.6GENERATOR AC

CONNECTION SYSTEM

These air-cooled generator sets are equipped with dual stator AC power windings. These two stator windings supply electrical power to customer electrical loads by means of a dual 2-wire connection system.

Generators may be installed to provide the following outputs:

1)120 VAC loads only — one load with a maximum total wattage requirement equal to the generator’s rated power output (in watts), and 120V across the generator output terminals. (See Fig. 5.1 below)

2)120/240 VAC loads — one load with a maximum total wattage requirement equal to the generator’s rated power output, and 240 V across the generator output terminals; or two seperate loads, each with a maximum total wattage requirement equal to half of the generator’s rated power output (in watts), and 120 V across the generator output terminals. (See Fig. 5.3 on page 22)

Figure 5.1 – Connection for 120 Volts Only

20 Generac® Power Systems, Inc.

Image 22
Contents This manual should remain with the unit Authorized Service Dealer Location IntroductionTable of Contents General Hazards Electrical Hazards Generator Identification Reference Number IdentificationGenerator Applicability InstallationSafety Generator AC Connection System1.1 Fuel Consumption gph/lbs.ph SpecificationsFuel Requirements Gasoline Generator Control Panel Automatic Choke Optional Remote START/STOP PanelBefore Starting the Engine Stopping the Generator Starting the GeneratorLetting the Engine Stabilize Protection Systems High Temperature SwitchLOW OIL Pressure Switch Field Boost6 25-HOUR CHECK-UP Checking the Engine OIL LevelOvervoltage Protection 5 25-HOUR BREAK-IN PeriodCleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Clean Spark Arrestor Checking the Engine Spark PlugWeekly Cleaning the GeneratorBattery Maintenance Every SIX MonthsDrive Belt OUT of Service ProcedureRV Generator Service Interval Exercising the GeneratorQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Equipment Description Purpose and Scope Installation InstructionsStandards Booklets Generator Engine Operating SpeedDimensions Drawing No E1058-A Location and Support Generator LocationCompartment Size Generator CompartmentsSuspended Mounting Generator RestraintSound Insulating Materials Typical Compartment ConstructionCompartment Floor Cutouts Cooling and Ventilating AIRAcoustics Generator AirflowTesting the Installation Gasoline Fuel SystemGenerator Fuel Supply Line LP GAS Fuel SystemParts not Included in Fuel System Vapor Withdrawal Primary RegulatorSome Important Considerations Gaseous CarburetionLeakage Tests Exhaust SystemFuel Supply Lines Excess Flow ValveMufflers and Spark Arrestors Exhaust System SafetyElectrical Connections Electrical Junction BOXPower Supply Cord WiringIsolating Different Power Sources Generator AC ConnectionsBattery Cables Battery InstallationRecommended Battery Battery Cable Connections18 Transfer Switch Isolation Method Before Initial START-UP Optional AccessoriesPost Installation Tests Initial StartTesting Under Load Installation ChecklistTroubleshooting Guide Problem Cause CorrectionQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.