Bryant ASPAX1BBA015 owner manual Mounting Dimensions

Page 25

743

[29

308

[12"]

704

[27.7"]

207 [8.14"]

TRANSFER SWITCH

AIR

490.7 [

Ø30.2mm [Ø1.19"]

914mm [ 36.0" ]

MINIMUM OPEN AREA

ALL AROUND UNIT

NTAKE

(IF SUPPLIED)

LIFTING HOLES 4-CORNERS

716 [28

"DO NOT LIFT BY THE ROOF"

604 [23.5"]

1193 [47"]

622 [24.5"]

1232 [48.5"]

LEFT SIDE VIEW

FRONT VIEW

76.2mm

[3.00"]

PEA GRAVEL

MINUMUM

149

[5.9"]

RIGHT SIDE VIEW

1172.3 [46.2"]

3/4" NPT FUEL INLET

GAS PRESSURE OF 11-14"

WATER COLUMN REQUIRED

CABLE ACCESS HOLES. (REMOVE PLUG FOR ACCESS)

260ROUNDING LUG

[10.2"]

REAR VIEW

**ALL DIMENSIONS IN:

MILLIMETERS [INCHES]

Drawing No.

15 kW

0D3739-B

Generator

 

 

 

 

Section 6 — Mounting Dimensions

23

Image 25
Contents Installation ‹ Operation and Maintenance ‹ Contents‹ HOW to Obtain Service IntroductionMaintenance Post Installation Start-up AdjustmentsTroubleshooting Introduction Inside Front Cover Warning  ‹ Standards Index  Explosion Hazards Location UNPACKING/INSPECTIONProtection Systems System SET LEDGfci GeneratorFuel Requirements Recommendations SpecificationsFuel Consumption ‹ 1.6.1 Generator‹ 1.9.1 15KW, 990CC Engines Fuel System‹ 1.10.1 Generator Battery Battery Installation‹ 1.10.2 Transfer Switch 10.2.1 15 kW UnitsBefore Initial START-UP Check Transfer Switch OperationElectrical Checks Checking Automatic Operation Generator Tests Under LoadDual Fuel Regulators Adjusting the Regulator Natural GAS onlyBREAK-IN Procedure Voltage Regulator Adjustment‹ 2.7.1 15 KW Units Automatic Transfer Operation ‹ 3.3.1 12 VDC Accessory Outlet‹ 3.2.1 Auto Position ‹ 3.2.2 OFF PositionSequence of Automatic Operation ‹ 3.5.1 Transfer to Generator Power SourceManual Transfer Operation ‹ 3.3.2 120 VAC Gfci Outlet‹ 3.5.2 Transfer Back to Utility Power Source Setting the Exercise Timer‹ 3.7.1 LOW OIL Pressure Switch ‹ 3.7.2 High Temperature SwitchFuses Checking the Engine OIL LevelChanging the Engine OIL Changing the OIL Filter ‹ 4.3.2 OIL Change ProcedureSpark Plugs ‹ 4.5.1 15 KW GeneratorsAdjusting Valve Clearance Battery MaintenanceCorrosion Protection Cooling System‹ 4.12.1 Removal from Service OUT of Service Procedure‹ 4.12.2 Return to Service Be performed by the nearest dealer Service ScheduleProblem Cause Correction Troubleshooting GuideMounting Dimensions Electrical Data Customer Connection KW Generator Electrical Schematic Drawing No E9017 SW1 Exploded Views and Parts Lists Part NO. QTY. Description KW Generator Control Panel Drawing No E9162-J Part NO. QTY Description 16B Item Part NO. QTY. Description 138 122 KNOB, AIR Cleaner Views and Parts Lists QTY Description KW Generator Gas Regulator Drawing No D8720-G CASTING, Twin Regulator Housing California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule