AEG 2.33 2 user manual Control panel and display description, Control panel parts, Touch Screen

Page 41

41

6. Control panel and display description

6.1. Control panel parts

(1)(LEDs) LED indications:

(a)Rectifier Input Voltage OK (green)

(b)Unit on Bypass (orange)

(c)Inverter is working (green)

(d)Unit working from batteries -mains failure (red).

(e)In case of any alarm of the unit (red)

(2)Graphic Display

(3)Keyboard

ENT “Enter” key. Confirmation of orders, program values (or other specified functions)

“Left” key for submenu navigation, or cursor displacement

“Right” key for submenu navigation, or cursor displacement

“Up” key for menu page navigation, or digit modification

“Down” key menu page navigation, or digit modification.

ESC “Escape” key. Return to previous screen, cancel/finish programming (or other specified functions)

By pressing the “right“ and “left“ keys you will see the titles on the sub menus and can navigate between the different displays.

6.1.1. Touch Screen

The touch functionality of the screen can be used by touching the screen. Simply type with your finger on the appropriate fields or text.

6.2. Basic functions of keyboard from synoptic

Through keys advance and return , there is access to all the menus of the LCD panel, and being able to move from one to another.

Through keys right or left , there is access to the screens of all the submenus of the LCD panel, being able to move from one to another with themselves.

Image 41
Contents Protect 2.33 Contents Operation Maintenance, warranty and service Introduction Using this manualSymbols and conventions used For more information and help Safety and instructionsManagement declaration Quality and standard guaranteeEnvironmental protection StandardsViews Views of the equipment PresentationNot available for Protect 2.33 No -3 battery cabinet front view with front door closed Corresponding legends for the equipment views LCD Operating principle Structure Structural schemaOperation with inverter not active Normal operationOperation with mains failure Parallel operation Operation in manual bypassThere are two operation modes possible Important safety instructions InstallationBattery safety instructions Cabinet access Bypass Input Output Set up and installation Unpacking and content checking Transportation to site StorageLocation Front view for parallel system Connection To the mains connection, terminals X1 toPage Connection of the output, terminals X6 to Page Connection example between a UPS and two battery cabinets Interface relay contacts, connectorConnector DB9 X31 COM-interface RS232 and RS485, connectorPage Parallel BUS connection EPO terminalsParallel BUS Connection Start up Control before start up Start up procedureOperation Close Battery Switch LED indications control panel PC Complete UPS shutdown Transfer to maintenance bypass Emergency power off EPO operation Bypass manual switch Maintenance Principle of operation Transfer to normal operation Close Battery Switch Control panel parts Control panel and display descriptionTouch Screen Basic functions of keyboard from synopticControl panel parts Main Messages menus and classification in submenusMenu structure Screen 0.0 Main Screen Screen description Main level screen menuMain UPS status control screen menuPage 3. ‘‘MEASURES level screen menu Page Page Screen 3.0 Settings and its submenus 4. ‘‘SETTINGS level screen menuModbus Screen Page Page 5. ‘‘ALARMS level screen menu UPS Rectifier blocks Alarm list displayed in the LCD panel Alarm Page Page Alarm Page Page Page Page Alarm Error in configuration memory Screen 5.0 Data logger  6. ‘‘DATA Logger level screen menuPage Basic maintenance guide Maintenance, warranty and serviceBattery fuses BatteriesCapacitors Warranty conditionsCooling Fan Annexes Static Bypass Type Dimensions & Weight External Battery Cabinet External battery cabinetTo provide for Safety InstructionsPage Page Page Operating Instructions 8000032013 BAL, EN