AEG 2.33 2 user manual Rectifier blocks

Page 58

58

Inverter stopped due to shutdown

Maintenance bypass. Inverter stop

Parallel system disconnection. Inverter stop

High overload. Inverter stop

Over temperature. Inverter stop

Rectifier overload. Inverter stop

Inverter stops

DSP internal error. Inverter stop

Output short-circuit. Inverter stop

Bypass phase rotation. Inverter stop

Inverter failure/overload. Inverter stop

Voltage ramp error. Inverter stop

Parallel system inverter stop

Low battery. UPS stop

DSP internal error. UPS stop

27

28

29

30

31

32

33

34

35

65

67

70

36

37

PFC., Inv. stop UPS stop

UPS stops

71

Parallel system UPS stop

Emergency power off. No output voltage

Output short-circuit. No output voltage

Byp stops

 

 

DSP internal error. UPS block all

 

DC BUS voltage wrong. Rectifier block

 

 

 

Rectifier blocked. BLK. UPS -> BLK rec.

 

Rectifier desaturations. Rectifier block

 

Voltage ramp error. Rectifier block

Rectifier blocks

DSP execution error. Rectifier block

DSP internal error. Rectifier block

Contactor test failure. Rectifier block

Voltage ramp error. Inverter block

Output DC voltage. Inverter block

Inverter blocked. BLK. UPS -> BLK inverter

Inverter desaturations. Inverter block

Inverter blocks

DSP execution error. Inverter block

 

 

 

DSP internal error. Inverter block

 

 

 

Inverter failure. Inverter block

 

UPS blocked. BLK. Rectifier -> BLK. UPS

UPS blocks

72

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

66

54

Image 58
Contents Protect 2.33 Contents Operation Maintenance, warranty and service Using this manual IntroductionSymbols and conventions used Safety and instructions For more information and helpQuality and standard guarantee Management declarationStandards Environmental protectionPresentation Views Views of the equipmentNot available for Protect 2.33 No -3 battery cabinet front view with front door closed Corresponding legends for the equipment views LCD Structure Structural schema Operating principleOperation with mains failure Normal operationOperation with inverter not active Operation in manual bypass Parallel operationThere are two operation modes possible Installation Important safety instructionsBattery safety instructions Cabinet access Bypass Input Output Set up and installation Unpacking and content checking Storage Transportation to siteLocation Connection To the mains connection, terminals X1 to Front view for parallel systemPage Connection of the output, terminals X6 to Page Interface relay contacts, connector Connection example between a UPS and two battery cabinetsCOM-interface RS232 and RS485, connector Connector DB9 X31Page EPO terminals Parallel BUS connectionParallel BUS Connection Operation Start up procedureStart up Control before start up Close Battery Switch Complete UPS shutdown LED indications control panel PCBypass manual switch Maintenance Principle of operation Emergency power off EPO operationTransfer to maintenance bypass Transfer to normal operation Close Battery Switch Touch Screen Control panel and display descriptionControl panel parts Basic functions of keyboard from synopticControl panel parts Messages menus and classification in submenus MainMenu structure Screen description Main level screen menu Screen 0.0 Main ScreenUPS status control screen menu MainPage 3. ‘‘MEASURES level screen menu Page Page 4. ‘‘SETTINGS level screen menu Screen 3.0 Settings and its submenusModbus Screen Page Page 5. ‘‘ALARMS level screen menu UPS Rectifier blocks Alarm list displayed in the LCD panel Alarm Page Page Alarm Page Page Page Page Alarm Error in configuration memory 6. ‘‘DATA Logger level screen menu Screen 5.0 Data logger Page Battery fuses Maintenance, warranty and serviceBasic maintenance guide BatteriesCooling Fan Warranty conditionsCapacitors Annexes Static Bypass Type External battery cabinet Dimensions & Weight External Battery CabinetSafety Instructions To provide forPage Page Page Operating Instructions 8000032013 BAL, EN