Lenovo 992, 981, 1008, 1010 manual Running tests, Test results

Page 20

The Enter key is used to select a menu item.

The Esc key is used to back up to the previous menu.

For online help, select F1.

Running tests

There are four ways to run the diagnostic tests.

Using the cursor movement keys, highlight Run Normal Test or Run Quick Test from the Diagnostics menu and then press Enter. This automatically runs a pre-defined group of tests from each test category. Run Normal Test runs a more extensive set of tests than Run Quick Test does and takes longer to complete.

Press F5 to automatically run all selected tests in all categories.

From within a test category, press Ctrl+Enter to automatically run only the selected tests in that category.

Using the cursor movement keys, highlight a single test within a test category, and then press Enter. This runs only that test.

Press Esc at any time to stop the testing process.

Test results (N/A, PASSED, FAILED, ABORTED) are displayed in the field beside the test description and in the test log. See “Viewing the test log” on page 15.

To select one or more tests, do the following:

1.Open the corresponding test category.

2.Using the cursor movement keys, highlight the desired test.

3.Press the space bar. A selected test is marked by >>. Pressing the space bar again de-selects a test and removes the >>.

4.Repeat steps 2 and 3 above to select all desired tests.

Test results

Diagnostics test results produce the following error code format:

Function Code

Failure Type

DeviceID

Date

ChkDigits

Text

 

 

 

 

 

 

Function Code:Represents the feature or function within the server.

Failure Type:Represents the type of error encountered.

DeviceID:Contains the component's unit-ID that corresponds to a fixed disk drive, removable media drive, serial or parallel port, processor, specific RIMM, or a device on the PCI bus.

Date:Contains the date when the diagnostic test was run. The date is retrieved from CMOS and displayed using the YYYYMMDD format.

ChkDigits:Contains a 2-digit check-digit value to ensure the following:

Diagnostics were run on the specified date.

Diagnostics were run on the specified server.

The diagnostic error code is recorded correctly.

Text:Description of the error.

Note: See Chapter 4 “Diagnostics” on page 13 for error code listings.

14ThinkServerHardware Maintenance Manual

Image 20
Contents ThinkServer Hardware Maintenance Manual Page ThinkServer Hardware Maintenance Manual Second Edition December Copyright Lenovo Contents Index Important Safety Information About this manualSafety statements To Connect To DisconnectAbout this manual ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb Important information about replacing RoHS compliant FRUs ThinkServerHardware Maintenance Manual Features and specifications General informationPower supply System management featuresInput/Output I/O features Security featuresEasyManage SoftwareEasyStartup ThinkServerHardware Maintenance Manual Problem determination tips General CheckoutThinkServerHardware Maintenance Manual Diagnostics PC-Doctor for DOS Creating a diagnostic discRunning the diagnostic program from a diagnostic disc Navigating through the diagnostics programsRunning tests Test resultsViewing the test log Troubleshooting tablesHard disk drive boot error Power Supply Problems Beep symptomsError FRU/Action Beep Symptom FRU/ActionPost error codes Long and 9 short beeps Bios ROM errorContinuos long beeps Dram memory error Post Error Message Description/ActionEasyStartup problems Hard Disk Install FailureDisplay/Monitor Miscellaneous error messagesMessage/Symptom FRU/Action First device network Second device hard diskUndetermined problems ThinkServerHardware Maintenance Manual Rear view Locating Server Controls and connectorsFront view Connector Description System-board internal connectors System board connector locationsInternal components Component locationsInspecting for unsafe conditions Guidelines for trained service techniciansReplacing FRUs Guidelines for servicing electrical equipment Handling static-sensitive devicesServer components Replacing FRUs Removing the server coverRemoving and reinstalling the front bezel Removing the server coverInstalling or replacing a PCI card Removing the front bezelOpening the PCI card latch Removing a PCI card Replacing the battery Installing a PCI cardInstalling or replacing a memory module Removing the old batteryOpening the retaining clips Installing or replacing the optical drive Installing a memory moduleRemoving the optical drive Installing a secondary hard disk drive Replacing the secondary hard disk driveRemoving the secondary hard disk drive cage Installing the secondary hard disk drive Replacing the power supply assembly Removing the screws for the power supply assemblyReplacing the heat sink and fan assembly Removing the heat sink and fan assembly Replacing the microprocessorThinkServerHardware Maintenance Manual Replacing the system board Removing the microprocessorRemoving the system board Installing the socket cover Replacing the primary hard disk drive Removing the primary hard disk driveInstalling the hard disk drive into the bracket Installing the primary hard disk drive Replacing the front fan assembly Removing the front fan assembly Replacing the rear fan assembly Installing the front fan assemblyRemoving the rear fan assembly Completing the parts replacement Installing the rear fan assemblyUpdating the server configuration Reinstalling the server coverFRUs Parts Listing, TS200v Machine Types 0981, 0992, 1008,Machine Type CTO FRUs listed in the following tables are not illustrated Line CordsWindows Server 2008 R2 Foundation 64-bit Windows Small Business Server 2008 Standard w/ SP2 Ship GroupsWindows Server 2008 R2 Standard 64-bit Microprocessor, Intel Celeron, 2.26G/2M-L2 models CTO Lenovo RDX drive bay models CTO All Models Lenovo RDX 320GB cartridge models CTO All Models 90Y1170 Microprocessor, Core i5-650 / 3.20GHz models CTO 15U 15Y Lenovo RDX drive bay models CTO All Models 256MB Nvidia FX380 2xDVI models CTO All models Windows Server 2008 R2 Foundation 64-bit 16G 16J 16L 16M 16S 16U 16Y Memory modules, DDR3 ECC PC3-10600 2GB Udimm 1333 models CTO 16U 16Y Line Cord Israel models CTO 16G ThinkServerHardware Maintenance Manual Configuring the server Using the Setup Utility programStarting the Setup Utility program Viewing and changing settingsUsing passwords Password considerationsUSB Setup Enabling or disabling a deviceSelecting a startup device Sata ControllerAdvanced settings Exiting from the Setup Utility programConfiguring RAID RAID LevelCreating RAID volumes Deleting RAID volumesUpdating flashing the Uefi from a disc Using system programsUpdating system programs Recovering from a POST/UEFI update failure Updating flashing the Uefi from your operating systemUsing the ThinkServer EasyStartup program Installing ThinkServer EasyManage Agent ThinkServerHardware Maintenance Manual Appendix A. Notices Export classification notice Television output noticeEuropean conformance CE mark Trademarks Electronic emissions noticesIndustry Canada Class B emission compliance statement European Union EMC Directive conformance statementThinkServerHardware Maintenance Manual Power cord notice Canadian Department of Communications certification labelPower cord part number Used in these countries and regions Waste electrical and electronic equipment Weee notices European Union EU Weee statement Disposing of disused lithium batteries from Lenovo computersAppendix A. Notices ThinkServerHardware Maintenance Manual Index CRURemoving Page Part Number 1P P/N