B-2
DuraLAN Fast Ethernet NICs User’s Guide

Isolating Faulty Hardware

If the problem persists, try the following:
Replace the NIC with the same type of Adaptec NIC which is
known to work. If the new NIC functions properly, the
problem is related to the original NIC.
Install the NIC in another functioning computer and run the
tests again. If the NIC works in this machine, the problem is
related to one of three areas:
The computer is faulty
There is a hardwa re conflic t
There are problems with the cables or connectors

Troubleshooting

Use the follow ing table to h elp answer common questions. For mor e
information on FAQs, see the

www.adaptec.com

support site.
Symptom Solution
Adaptec NIC i s
conflict ing with an
installed PCI SCSI
Adapter.
Config ur e t he NIC a nd SCSI ad apte rs to u se
different interrupts via BIOS, System
Configuration Utility (SCU), or EISA
Configuration Utility (ECU) provided by
the system vendor.
Workst ations cannot
connect to the NetWare
server.
Make sur e th e workstatio n a nd se rv er a re
using the same frame type.
Add the following two lines to the Net-
Ware Server
startup.ncf
file:
set minimum packet receive buffers=512
set maximum packet receive buffers=1024
For Failover and Port Aggregation Net-
Ware servers, verify that IPX retry count=
255 is on each workstation. See Connect-
ing Clients to the NetWare Failover Server
on page 12-6.
Error messages during
NetWare Driver
installation.
Install NetWare service pack 6(iwsp6) or
later, select ODI 3.31 specification, and then
install the DuraLAN NIC driver.