Sanyo PDG-DHT100L owner manual Power management, On start

Page 57

Setting

Power management

For reducing power consumption as well as maintaining the lamp life, the Power management function turns off the projection lamp when the projector is not used for a certain period.

If the input signal is interrupted and no button is pressed for more than 30 seconds, the timer display with “No signal” appears. It starts the countdown until the lamp is turned off. The countdown time can be set between 1 and 30 minutes.

Use the Point 7 8 buttons to set the countdown timer.

Select one of the following options:

Ready . .

When the lamp has been fully cooled down,

 

the POWER indicator starts blinking. In this

 

condition, the projection lamp is turned on if the

 

input signal is reconnected or any button on the

 

side control or remote control is pressed .

Shutdown .

When the lamp has been fully cooled down, the

 

power is turned off.

Off . . .

Power Management function is off.

On start

When this function is set to “On,” the projector will be automatically turned on just by connecting the AC power cord to the wall outlet.

Note:

Make sure that the MAIN ON / OFF switch is ON, otherwise the On start function does not work.

Be sure to turn off the projector properly (see “Turning Off the Projector” on page 25). If the projector is turned off in the incorrect sequence, the On start function does not work properly.

Power management

Time left before the lamp is off

Press the SELECT button at Power management and the dialog box appears. Use the Point 7 8 buttons to choose one of the three options. Press the Point d button to select the timer, and then use the Point 7 8 buttons to set the timer.

Note:

•Factory default is “Ready: 5 min.”

•When the shutter is closed while the Power management function is working, the Power management function is released.

57

Image 57 Contents
Model PDG-DHT100L Features and Design Table of Contents Risk of Electric Shock Do not Open To The OwnerSafety Instructions Top Panel Air CirculationPositioning Precautions Installing the Projector in Proper DirectionsMoving the Projector AC Power Cord for the United Kingdom AC Power Cord for the United States and CanadaCompliance Canadian Radio Interference RegulationsPart Names and Functions Front!0Back Terminals and Connectors Side Control Side Control and IndicatorsIndicators Remote Control Remote Control Battery Installation Remote Control Receivers and Operating RangeWired Remote Control Remote Control Code Installation Lens InstallationPositioning Projector Picture Level and Pitch Adjustment Lens Shift AdjustmentWhen the lens is shifted to top When the lens is shifted to bottomTerminals of Projector Replacement of TerminalConnecting to Computer Cables used for connectionTerminals of the projector Connecting to Video Equipment Monitor Out Signal TableProjector Attaching the Cable Cover Connecting the AC Power Cord For the U..KFor the U..S..A.. and Canada For Continental Europe Basic Operation What is PIN code?Turning On the Projector Enter a PIN codeTurning Off the Projector Unplug the AC power cord from the AC outletRemote Control How to Operate the On-Screen MenuSide Control On-Screen MenuMenu Bar Operating with Projector Control Information Operating with Remote Control Shutter button Timer buttonFilter button Image ADJ.. buttonInput Selection Remote Control OperationInput Side Control OperationComputer Input Source Selection When Selecting the Input 1 with DVI/D-sub 15 terminalsMenu Operation Input MenuRGB Scart Video Input Source SelectionRGB AV Hdcp Pb/Cb, Pr/CrComputer System Selection Computer InputAutomatic Multi-Scan System Selecting Computer System ManuallyTo store the adjusted parameters Auto PC AdjustmentPC Adjust Menu Direct OperationManual PC Adjustment Mode free ResetTo clear the adjusted data To store the adjusted dataStandard Real Dynamic Image1 Image SEL.. button Image Level SelectionStandard ImageScreen Menu Screen Size AdjustmentCeiling KeystoneRear Digital zoom +Video System Selection Video InputVideo Jack or S-Video Jack Pb/Cb, Pr/Cr JacksStandard Cinema Dynamic Image1 Image SEL.. button Natural Wide ZoomKeystone Image Adjust Menu Image AdjustmentPointer Mode Picture ImageMenu Color MColor Palette DELOffset Red/Green/Blue White balance Red/Green/BlueSharpness GammaSetting SettingBackground Lamp modeLamp control Lamp life controlPicture in Picture Color matching Edge blending DynamicBlack Advanced color matchingLogo Hdmi setupLogo select CaptureChange the Logo PIN code lock setting Enter a Logo PIN codeChange the Logo PIN code To change the code for the remote control Remote controlTo reset the code for the remote control Filter controlOn start Power managementPIN code lock Security Key lockSecurity Key lock PIN code lockChange the PIN code lock setting Change the PIN Code Lock settingChange the PIN Code Enter a PIN codeShutter ProtectionManagement Factory default Filter counterTest pattern Filter Instructions Maintenance and CareReset the filter counter and the scroll counter p.64 Service Parts Code 610 334Replacing the Filter Cartridge Scroll counter Filter counterLamp Mode Changeover Lamp 1/2 Replace IndicatorsLamp Management Lamp Status DisplayLamp Replacement IndicatorsLamp 1 / 2 Replace indicators Model No.. of your projector Replacement Lamp Type NoOptional Color Wheel Installation Cleaning the Projector Cabinet Cleaning the Projection LensThen check the matters below Lamp indicator lights on and other indicators blinkAppendix TroubleshootingAppendix Power is turned off Menu Tree Information Image AdjustComputer Input/Video Input NetworkSystem PC AdjustImage Select ScreenSetting Projector is operating normally Indicators and Projector ConditionLamp Replace 1 Projector is detecting abnormal conditionFig..4 ON-SCREEN Resolution Compatible Computer SpecificationsFreq..kHz Freq..Hz DisplayKHz FreqOn-Board List of Picture in PictureTechnical Specifications POA-MD23ADI Optional PartsControl Port Connector D-sub 9 pin Configurations of TerminalsInput OutputPIN Code Number Memo PIN Code Lock NoLogo PIN Code Lock No Dimensions Serial Control Interface Functional Execution CommandOperation ExampleStatus Read Command KT5AL-A