Message table (continued) |
| |||||||
|
|
|
|
|
|
|
|
|
Indicator display | The ON indicator, LAMP indicator and TEMP indicator will light or |
| ||||||
|
|
|
| |||||
|
|
| blink in the following cases. |
|
|
|
| |
|
|
|
|
|
|
|
|
|
ON indicator | LAMP indicator |
| TEMP indicator | Meaning |
| Remedy |
| |
|
|
|
|
|
|
|
|
|
Lights orange | Goes off |
| Goes off | Standby mode |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
Blinks green | Goes off |
| Goes off | During warming up |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
Lights green | Goes off |
| Goes off | During operation *1 |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
Blinks orange | Goes off |
| Goes off | During cooling down |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cool projector by power off for 45 |
| ||
Lights red | Lights red |
| Goes off | Lamp cannot light | minutes. |
| ||
| If the indicator is still it, lamp may be |
| ||||||
|
|
|
|
|
| |||
|
|
|
|
| defective. Replace. |
| ||
|
|
|
|
|
|
|
|
|
Lights red | Blinks red |
| Goes off | Lamp is not inserted or the | Securely insert the lamp or close the |
| ||
| lamp door open | lamp door. |
| |||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
Lights red | Goes off |
| Lights red | Temperature inside too hight | Correctly reinstall so as not to block |
| ||
| ventilation holes. |
| ||||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Lights red | Goes off |
| Blinks red | Cooling fan accidented | Call a maintenance person. |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Accumulated lamp operation | Replace lamp and reset the |
| ||
Blinks red | Blinks red |
| Goes off | time has exceeded 2,000 | accumulated lamp operation time. |
| ||
|
|
|
| hours | (See page 28, 29) |
| ||
|
|
|
|
|
|
|
|
|
When the LAMP indicator lights, turn the power off. If the problem cannot be recovered, contact your dealer.
*1 Even when the indicator lights green, if the power supply section becomes too hot , the lamp may be automatically turned off to cool it down (indicator continues to light green). In this case, turn off the power switch and allow the unit to cool down before turning the power switch on again. The lamp will light. If the lamp does not light because it is still automatically turned off, contact your dealer.
*2 When inside temperature becomes high because ventilation holes are blocked, normally, TEMP indicator will light red. However, to protect the projector, the lamp may be turned off and at this time LAMP indicator may light red.
When you think something wrong
Check the following again before asking for service. If the trouble cannot be recovered, consult your dealer.
Phenomena | Cause |
| Check point | Page | |
|
|
|
| ||
Power cannot be | ∙The Main power is not turned on. | ∙Turn the MAIN POWER switch on. | P.12 | ||
∙The power cord is disconnected. | ∙Insert the power cord into an AC socket. | P.8 | |||
turned on. | ∙60 seconds have not elapsed since the | ∙When the power is turned off turn the power | P.12 | ||
| power was turned off. | switch on after waiting at least 60 seconds. |
| ||
No picture and | ∙The setting of the input source is not | ∙Set the correct input using the input select | P.7, 9, | ||
correct. | button of the projector or the remote control. | 12, 16 | |||
sound | |||||
∙Wiring to the projector is not correct. | ∙Connect the cable correctly. | P.8, 26 | |||
| |||||
|
|
|
| ||
Only picture is | ∙Wiring to the projector is not correct. | ∙Connect the cable correctly. | P.8, 26 | ||
∙The volume is set to minimum. | ∙Press the VOL button or press the MENU button | P.9, 15 | |||
displayed with no | |||||
| and adjust the volume. |
| |||
sound |
|
| |||
∙The unit enters the mute mode. | ∙Press the MUTE button. | P.7, 9 | |||
| |||||
Only sound is | ∙Wiring the projector is not correct. | ∙Connect the cable correctly. | P.8, 26 | ||
∙The brightness is set fully to the dark | ∙Press the MENU button and select BRIGHT and | P.15 | |||
heard without a | |||||
side. | press the | button. |
| ||
picture |
| ||||
∙Lens cap is attached. | ∙Remove the lens cap. | P.12 | |||
| |||||
|
|
|
| ||
Color is weak and | The color and tint have been adjusted | Adjust the color and tint correctly. | P.15 | ||
tint is incorrect | incorrectly. |
|
|
| |
| ∙The brightness and contrast has been | ∙Adjust the brightness and contrast correctly. | P.15 | ||
Picture is dark | adjusted incorrectly. |
|
|
| |
| ∙The lamp has not been adjusted. | ∙Replace the lamp with a new one. | P.28 | ||
|
|
|
| ||
Picture is not clear | Focus or H.PHASE is not matched. | Adjust the focus or H.PHASE | P.12, 15 | ||
|
|
|
| ||
LAMP indicator | Trouble with the lamp. | Turn off the power and leave for 45 minutes ; | P.30 | ||
lights red. | then turn the power on again. | ||||
|
| ||||
TEMP indicator |
| ∙Do not block the venational holes. | P.5 | ||
Inside the projector too hot. | ∙Clean the air filter. | P.27 | |||
lights red. | |||||
| ∙Use the projector under 35°C temperature. |
| |||
|
|
| |||
|
|
|
| ||
Remote control | ∙Cable was connected after the power | ∙Be sure to perform procedure in the following order: |
| ||
(1)Connect cable. (2)Turn on projector. (3)Turn PC on. |
| ||||
mouse cannot be | was turned on. |
| |||
∙Input video signal and select and display input |
| ||||
operated. | ∙Video signal not selected. |
| |||
source. |
|
| |||
|
|
|
| ||
|
|
|
|
|
30 A bright dot may be seen in the picture. This is a phenomenon peculiar to the liquid crystal and is not a problem.