NEC RS-232C user manual Header Message Check code Delimiter

Page 12

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Step 2. The monitor replies with current Brightness setting and capability to support this operation.

 

Header

 

 

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'

 

STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'

BCC

 

 

CR

 

 

 

 

-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX

 

 

 

 

 

 

 

Header

 

 

 

 

 

 

 

 

 

SOH (01h): Start Of Header

 

 

 

 

 

 

 

 

 

'0' (30h): Reserved

 

 

 

 

 

 

 

 

 

'0' (30h): Message receiver is the controller.

 

 

 

 

 

 

 

Monitor ID: Indicate a replying Monitor ID.

 

 

 

 

 

 

 

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

 

 

 

'D' (44h): Message Type is "Get parameter reply".

 

 

 

 

 

 

 

'1'-'2' (31h, 32h): Message length is 18 bytes.

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

STX (02h): Start of Message

 

No error.

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): Result code.

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): Operation code page number is 0.

 

 

 

 

 

 

 

'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): This operation is "Set parameter" type.

 

 

 

 

 

 

 

'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).

 

 

 

 

 

'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Brightness setting is 50(0032h) .

 

 

 

ETX (03h): End of Message

 

 

 

 

 

 

 

 

 

Check code

 

 

 

 

 

 

 

 

 

BCC: Block Check Code

 

 

 

 

 

 

 

 

 

Refer to the section 4.5 “Check code” for a BCC calculation.

 

 

 

 

 

 

 

Delimiter

 

 

 

 

 

 

 

 

 

CR (0Dh): End of packet

 

 

 

 

 

 

 

 

 

Step 3. The controller request the monitor to change the Brightness setting

 

 

 

 

 

Header

 

Message

 

 

Check

 

Delimiter

 

 

 

 

 

code

 

 

 

SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'

 

STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX

 

BCC

 

CR

 

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller .

'E' (45h): Message Type is "Set parameter command".

'0'-'A' (30h, 41h): Message length is 10 bytes.

Message

STX (02h): Start of Message

'0'-'0' (30h, 30h): Operation code page number is 0.

'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).

'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Brightness setting 80(0050h).

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

(12/50)

Image 12
Contents Connectors and wiring ApplicationCommunication Parameter Communication Format Header block format fixed lengthALL Message block format STXETX STX ETX MSB LSBCheck code MSB LSBSOH Delimiter Following is an example of a Check code BCC calculationMessage type Get current Parameter from a monitorSet parameter Set parameter reply Current conditionCommands Save Current SettingsGet Timing Report and Timing reply MSB LSB ETXTypical procedure example How to change the Brightness settingNull Message BCCHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power control procedure Power status readPower control Controller requests the monitor to control monitor powerAsset Data read and write Asset Data Read Request and replyAsset Data write Date & Time read and write Date & Time ReadBCC DS-ETX Date & Time Write Check code Delimiter Schedule read and write Schedule ReadSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t set Schedule WritePG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self diagnosis Self-diagnosis status readST Result of self-tests 0-030h, 30h00 Normal Serial No. & Model Name Read Serial No. ReadModel Name Read Security Lock Security Lock Control930h, 39h Page Dicom SIM ISFAdjust Surround HdmiPOP RGB/HVPIP OSD Option Sync DVI-PC DVI-HDNtsc SecamPIP ON/OFF All data are subject to change without notice