NEC RS-232C user manual STX-0-0-0-2-7-9-0-0

Page 15

Delimiter

CR (0Dh): End of packet

Step 3. The controller requests the monitor to send the temperature from the selected sensor.

 

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'

STX-'0'-'2'-'7'-'9'-ETX

BCC

CR

Header

 

 

 

SOH

(01h): Start of Header

 

 

 

'0'

(30h): Reserved

 

 

 

Monitor ID: Specify the Monitor ID which you want to get a value. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'C' (43h): Message Type is "Get parameter".

'0'-'6' (30h, 36h): Message length is 6 bytes.

Message

STX (02h): Start of Message

'0'-'2' (30h, 32h): Operation code page number is 2.

'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Step 4. The monitor replies a temperature of selected sensor.

Header

 

 

 

 

Message

 

 

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'

STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0'

 

BCC

CR

 

 

 

-'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX

 

 

 

 

Header

 

 

 

 

 

 

 

 

 

 

 

SOH (01h): Start of Header

 

 

 

 

 

 

 

 

 

 

'0' (30h): Reserved

 

 

 

 

 

 

 

 

 

 

'0' (30h): Message receiver is the controller.

 

 

 

 

 

 

 

Monitor ID: Indicate a replying Monitor ID.

 

 

 

 

 

 

 

 

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

 

'D' (44h): Message Type is "Get parameter reply".

 

 

 

 

 

 

'1'-'2' (31h, 32h): Message length is 18 bytes.

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

STX (02h): Start of Message

 

 

 

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): Result code. No error.

 

 

 

 

 

 

 

 

'0'-'2' (30h, 32h): Operation code page number is 2.

 

 

 

 

 

 

'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).

 

 

 

 

 

'0'-'0' (30h, 30h): This operation is "Set parameter" type.

 

 

 

 

 

'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value.

 

 

 

 

 

 

'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius.

 

 

 

Readout value is 2's complement.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature [Celsius]

Readout value

 

 

 

 

 

 

 

Binary

 

 

Hexadecimal

 

 

 

 

 

 

 

 

 

 

 

 

 

+125.0

 

0000 0000 1111 1010

00FAh

 

 

 

 

+

25.0

 

0000

0000

0011

0010

0032h

 

 

 

 

+

0.5

 

0000

0000

0000

0001

0001h

 

 

 

 

0

 

 

0000

0000

0000

0000

0000h

 

 

 

 

-

0.5

 

1111

1111

1111

1111

FFFFh

 

 

 

 

-

25.0

 

1111

1111

1100

1110

FFCEh

 

 

 

 

-

55.0

 

1111

1111

1001

0010

FF92h

 

 

 

ETX (03h): End of Message

(15/50)

Image 15
Contents Connectors and wiring ApplicationCommunication Parameter Header block format fixed length Communication FormatALL STX ETX MSB LSB Message block formatSTX ETXCheck code MSB LSBSOH Following is an example of a Check code BCC calculation DelimiterGet current Parameter from a monitor Message typeSet parameter Current condition Set parameter replyMSB LSB ETX CommandsSave Current Settings Get Timing Report and Timing replyBCC Typical procedure exampleHow to change the Brightness setting Null MessageHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power status read Power control procedureController requests the monitor to control monitor power Power controlAsset Data Read Request and reply Asset Data read and writeAsset Data write Date & Time read and write Date & Time ReadBCC DS-ETX Date & Time Write Check code Delimiter Schedule Read Schedule read and writeSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX Schedule Write B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t setPG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self-diagnosis status read Self diagnosisST Result of self-tests 0-030h, 30h00 Normal Serial No. & Model Name Read Serial No. ReadModel Name Read Security Lock Control Security Lock930h, 39h Page ISF Dicom SIMAdjust Hdmi SurroundPOP RGB/HVPIP OSD Option Secam SyncDVI-PC DVI-HD NtscPIP ON/OFF All data are subject to change without notice