Message

STX (02h): Start of Message

'C'-'2'-'1'-'2' (43h, 32h, 31h, 32h): Date & Time write command

'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data

YY:Year (offset 2000) '0'-'0'(30h, 30h): 2000

'6'-'3'(36h, 33h): 2099 (99 = 63h)

MM:Month

'0'-'1'(30h, 31h): January

'0'-'C'(30h, 43h): December

DD: Day

'0'-'1'(30h, 31h): 1

'1'-'E'(31h, 45h): 30(=1Eh)

'1'-'F'(31h, 46h): 31(=1Fh)

WW: weekdays

'0'-'0'(30h, 30h): Sunday

'0'-'1'(30h, 31h): Monday

'0'-'2'(30h, 32h): Tuesday

'0'-'3'(30h, 33h): Wednesday

'0'-'4'(30h, 34h): Thursday

'0'-'5'(30h, 35h): Friday

'0'-'6'(30h, 36h): Saturday

HH: Hours '0'-'0'(30h, 30h): 0

'1'-'7'(31h, 37h): 23 (=17h)

MN: Minutes '0'-'0'(30h, 30h): 0

'3'-'B' (33h, 42h): 59 (=3Bh)

DS: Daylight saving (Summer time) '0'-'0'(30h, 30h): NO '0'-'1'(30h, 31h): YES

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

2) The monitor replies a data for confirmation.

Header

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-'1'-'6'

STX-'C'-'3'-'1'-'2'-ST-YY-MM-DD-WW-HH-MN

BCC

CR

-DS-ETX

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

'0' (30h): Message receiver is the controller.

Monitor ID: Indicate a replying Monitor ID.

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

'B' (42h): Message type is "Command reply".

'1'-'6'(31h, 36h): Message length

Message

STX (02h): Start of Message

'C'-'3'-'1'-'2' (43h, 33h, 31h, 32h): Date & Time write reply command

(22/50)

Image 22
Contents Application Connectors and wiringCommunication Parameter Communication Format Header block format fixed lengthALL ETX Message block formatSTX STX ETX MSB LSBMSB LSB Check codeSOH Delimiter Following is an example of a Check code BCC calculationMessage type Get current Parameter from a monitorSet parameter Set parameter reply Current conditionGet Timing Report and Timing reply CommandsSave Current Settings MSB LSB ETXNull Message Typical procedure exampleHow to change the Brightness setting BCCHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power control procedure Power status readPower control Controller requests the monitor to control monitor powerAsset Data read and write Asset Data Read Request and replyAsset Data write Date & Time Read Date & Time read and writeBCC DS-ETX Date & Time Write Check code Delimiter Schedule read and write Schedule ReadSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t set Schedule WritePG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self diagnosis Self-diagnosis status readST Result of self-tests 0-030h, 30h00 Normal Serial No. Read Serial No. & Model Name ReadModel Name Read Security Lock Security Lock Control930h, 39h Page Dicom SIM ISFAdjust Surround HdmiRGB/HV POPPIP OSD Option Ntsc SyncDVI-PC DVI-HD SecamPIP ON/OFF All data are subject to change without notice
Related manuals
Manual 72 pages 50.57 Kb