NEC RS-232C user manual STX-C-2-1-4-PG-ON HOUR-ON MIN

Page 33

***Following command also can be used for to keep backward compatibility, in order to write the setting of the Schedule.

1) The controller requests the monitor to write Schedule.

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'1'-'6'

STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MIN-

BCC

CR

OFF HOUR-OFF MIN-INPUT-WD-FL-ETX

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'1'-'6'(31h, 36h): Message length.

Message

STX (02h): Start of Message

'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command

PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data PG: Program No.

'0'-'0'(30h, 30h): Program No.1

'0'-'6'(30h, 36h): Program No.7

ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): ON timer isn't set.

ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59

'3'-'C'(33h, 43h): On timer isn’t set.

OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): Off timer isn't set.

OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59 (=3Bh)

'3'-'C'(33h, 43h): Off timer isn’t set.

INPUT: Timer input '0'-'0'(30h, 30h): DVI '0'-'1'(30h, 31h): VGA '0'-'2'(30h, 32h): RGB/HV '0'-'3'(30h, 33h): DVD/HD1 '0'-'4'(30h, 34h): VIDEO '0'-'5'(30h, 35h): S-VIDEO

'0'-'7'(30h, 37h): (Works on last memory)

*Please select active input on your system (setting).

*If you select inactive input here, the input change execution will be ignored.

WD: Week setting bit 0: Monday bit 1: Tuesday bit 2: Wednesday bit 3: Thursday

(33/50)

Image 33
Contents Connectors and wiring ApplicationCommunication Parameter Header block format fixed length Communication FormatALL STX Message block formatETX STX ETX MSB LSBCheck code MSB LSBSOH Following is an example of a Check code BCC calculation DelimiterGet current Parameter from a monitor Message typeSet parameter Current condition Set parameter replySave Current Settings CommandsGet Timing Report and Timing reply MSB LSB ETXHow to change the Brightness setting Typical procedure exampleNull Message BCCHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power status read Power control procedureController requests the monitor to control monitor power Power controlAsset Data Read Request and reply Asset Data read and writeAsset Data write Date & Time read and write Date & Time ReadBCC DS-ETX Date & Time Write Check code Delimiter Schedule Read Schedule read and writeSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX Schedule Write B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t setPG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self-diagnosis status read Self diagnosisST Result of self-tests 0-030h, 30h00 Normal Serial No. & Model Name Read Serial No. ReadModel Name Read Security Lock Control Security Lock930h, 39h Page ISF Dicom SIMAdjust Hdmi SurroundPOP RGB/HVPIP OSD Option DVI-PC DVI-HD SyncNtsc SecamPIP ON/OFF All data are subject to change without notice