2) The monitor replies a data for confirmation.

Header

Message

 

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-'2'-'8'

STX-'C'-'3'-'2'-'2'-ST-PG-ON HOUR-ON MIN-

 

BCC

CR

 

OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-

 

 

 

 

EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX

 

 

 

Header

 

 

 

 

SOH (01h): Start Of Header

 

 

'0' (30h): Reserved

 

 

 

 

'0' (30h): Message receiver is the controller.

 

 

Monitor ID: Indicate a replying Monitor ID.

 

 

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

 

'B' (42h): Message type is "Command reply".

 

 

'2'-'8'(32h, 38h): Message length

 

 

Message

 

 

 

 

STX (02h): Start of Message

 

 

'C'-'3'-'2'-'2' (43h, 33h, 32h, 32h): Schedule writes reply command

 

 

ST: Schedule Status command

 

 

'0'-'0'(30h, 30h): No error

 

 

'0'-'1'(30h, 31h): Error

 

 

PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE

 

 

EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data

 

 

PG: Program No.

 

 

 

 

'0'-'0'(30h, 30h): Program No.1

 

 

 

 

 

 

'0'-'6'(30h, 36h): Program No.7

 

 

ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): ON timer isn't set.

ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59

'3'-'C'(33h, 43h): On timer isn’t set.

OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): Off timer isn't set.

OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59 (=3Bh)

'3'-'C'(33h, 43h): Off timer isn’t set.

INPUT: Timer input

'0'-'0'(30h,30h): No mean (works on last memory)

'0'-'1'(30h,31h): VGA

'0'-'2'(30h,32h): RGB/HV

'0'-'3'(30h,33h): DVI

'0'-'5'(30h,35h): Video1

'0'-'6'(30h,36h): Video2

'0'-'7'(30h,37h): S-Video

'0'-'A'(30h,41h): TV

'0'-'C'(30h,43h): DVD/HD1

'0'-'D'(30h,44h): Option

'0'-'E'(30h,45h): DVD/HD2

'0'-'F'(30h,46h): Display Port

'1'-'1'(31h,31h): HDMI

WD: Week setting bit 0: Monday

(30/50)

Image 30
Contents Connectors and wiring ApplicationCommunication Parameter Communication Format Header block format fixed lengthALL ETX Message block formatSTX STX ETX MSB LSBCheck code MSB LSBSOH Delimiter Following is an example of a Check code BCC calculationMessage type Get current Parameter from a monitorSet parameter Set parameter reply Current conditionGet Timing Report and Timing reply CommandsSave Current Settings MSB LSB ETXNull Message Typical procedure exampleHow to change the Brightness setting BCCHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power control procedure Power status readPower control Controller requests the monitor to control monitor powerAsset Data read and write Asset Data Read Request and replyAsset Data write Date & Time read and write Date & Time ReadBCC DS-ETX Date & Time Write Check code Delimiter Schedule read and write Schedule ReadSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t set Schedule WritePG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self diagnosis Self-diagnosis status readST Result of self-tests 0-030h, 30h00 Normal Serial No. & Model Name Read Serial No. ReadModel Name Read Security Lock Security Lock Control930h, 39h Page Dicom SIM ISFAdjust Surround HdmiPOP RGB/HVPIP OSD Option Ntsc SyncDVI-PC DVI-HD SecamPIP ON/OFF All data are subject to change without notice