NEC RS-232C user manual Bcc

Page 35

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): Off timer isn't set.

OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59 (=3Bh)

'3'-'C'(33h, 43h): Off timer isn’t set.

INPUT: Timer input '0'-'0'(30h, 30h): DVI '0'-'1'(30h, 31h): VGA '0'-'2'(30h, 32h): RGB/HV '0'-'3'(30h, 33h): DVD/HD1 '0'-'4'(30h, 34h): VIDEO '0'-'5'(30h, 35h): S-VIDEO

'0'-'7'(30h,30h): No mean (Works on last memory)

WD: Week setting bit 0: Monday bit 1: Tuesday bit 2: Wednesday bit 3: Thursday bit 4: Friday bit 5: Saturday bit 6: Sunday

EX.

'0'-'1'(30h, 31h): Monday

'0'-'4'(30h, 34h): Wednesday

'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday

'7'-'F'(37h, 46h): Monday to Sunday

FL: Option

bit 0: 0:once 1:Everyday

bit 1: 0:once 1:Every week

bit 2: 0:Disable 1:Enable

* When bit 0 and bit 1 are '1', it behaves as Everyday.

EX.

'0'-'1'(30h, 31h): Disable, Everyday

'0'-'4'(30h, 34h): Enable, once

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

3)The controller requests the monitor to write Enable/Disable Schedule.

 

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'0'-'A'

STX-'C'-'2'-'1'-'5'-PG-EN-ETX

BCC

CR

Header

 

 

 

SOH

(01h): Start Of Header

 

 

 

'0'

(30h): Reserved

 

 

 

Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'0'-'A'(30h, 41h): Message length

Message

STX (02h): Start of Message

'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command

(35/50)

Image 35
Contents Communication Parameter Connectors and wiringApplication Header block format fixed length Communication FormatALL STX ETX MSB LSB Message block formatSTX ETXSOH Check codeMSB LSB Following is an example of a Check code BCC calculation DelimiterGet current Parameter from a monitor Message typeSet parameter Current condition Set parameter replyMSB LSB ETX CommandsSave Current Settings Get Timing Report and Timing replyBCC Typical procedure exampleHow to change the Brightness setting Null MessageHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power status read Power control procedureController requests the monitor to control monitor power Power controlAsset Data Read Request and reply Asset Data read and writeAsset Data write BCC DS-ETX Date & Time read and writeDate & Time Read Date & Time Write Check code Delimiter Schedule Read Schedule read and writeSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX Schedule Write B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t setPG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self-diagnosis status read Self diagnosisST Result of self-tests 0-030h, 30h00 Normal Model Name Read Serial No. & Model Name ReadSerial No. Read Security Lock Control Security Lock930h, 39h Page ISF Dicom SIMAdjust Hdmi SurroundPIP POPRGB/HV OSD Option Secam SyncDVI-PC DVI-HD NtscPIP ON/OFF All data are subject to change without notice
Related manuals