NEC RS-232C user manual Power control, Controller requests the monitor to control monitor power

Page 17

0001: ON

0002: Stand-by (power save)

0003: Suspend (power save)

0004: OFF (same as IR power off)

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

7.2Power control

1)The controller requests the monitor to control monitor power.

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'0'-'C'

STX-'C'-'2'-'0'-'3'-'D'-'6'-

BCC

CR

'0'-'0'-'0'-'1'-ETX

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'0'-'C (30h, 43h): Message length is 12 bytes.

Message

STX (02h): Start of Message

'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command

'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON

0002, 0003: Do not set.

0004: OFF (same as the power off by IR)

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

2) The monitor replies a data for confirmation.

Header

Message

Check ode

Delimiter

SOH-'0'-'0'-Monitor

STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6'-

BCC

CR

ID-'B'-'0'-'E'

'0'-'0'-'0'-'1'-ETX

 

 

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

'0' (30h): Message receiver is the controller.

Monitor ID: Indicate a replying Monitor ID.

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

'B' (42h): Message type is "Command reply".

'N'-'N': Message length

Note.) The maximum data length that can be written to the monitor at a time is 32bytes. Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).

Message

STX (02h): Start of Message

(17/50)

Image 17
Contents Communication Parameter Connectors and wiringApplication Header block format fixed length Communication FormatALL STX Message block formatETX STX ETX MSB LSBSOH Check codeMSB LSB Following is an example of a Check code BCC calculation DelimiterGet current Parameter from a monitor Message typeSet parameter Current condition Set parameter replySave Current Settings CommandsGet Timing Report and Timing reply MSB LSB ETXHow to change the Brightness setting Typical procedure exampleNull Message BCCHeader Message Check code Delimiter Message Check code Delimiter Code STX-0-0-0-2-7-9-0-0 Power status read Power control procedureController requests the monitor to control monitor power Power controlAsset Data Read Request and reply Asset Data read and writeAsset Data write BCC DS-ETX Date & Time read and writeDate & Time Read Date & Time Write Check code Delimiter Schedule Read Schedule read and writeSTX-C-3-2-1-PG-ON HOUR-ON MIN Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX Schedule Write B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t setPG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode Header 31/50 SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX STX-C-2-1-4-PG-ON HOUR-ON MIN 34/50 BCC Self-diagnosis status read Self diagnosisST Result of self-tests 0-030h, 30h00 Normal Model Name Read Serial No. & Model Name ReadSerial No. Read Security Lock Control Security Lock930h, 39h Page ISF Dicom SIMAdjust Hdmi SurroundPIP POPRGB/HV OSD Option DVI-PC DVI-HD SyncNtsc SecamPIP ON/OFF All data are subject to change without notice