TABLE OF CONTENTS

 

 

CONTENTS

 

PAGE

IMPORTANT SAFETY INSTRUCTIONS

ii

General Safety

ii

Voltages

ii

Battery

ii

Circuit Card Handling

iii

STATIC WARNING

iv

CHAPTER 1. SYSTEM OVERVIEW

1

Customer Documentation Package

1

System Description

1

CHAPTER 2. OPERATING PROCEDURES

3

Controller, Rectifiers, and Optional Converters

3

ESTOP Function

3

Local Controls and Indicators

3

Circuit Card Locations

3

System Interface Circuit Card

5

Optional LVD Driver Circuit Card

6

Optional LVD Driver Lite Circuit Card

7

Optional Manual Battery Disconnect Circuit Card

8

CHAPTER 3. MAINTENANCE

9

System Maintenance Procedures

9

Adding a Rectifier or DC-DC Converter Module to an Existing Module Mounting Assembly

..............................9

Installing a Field Expansion Module Mounting Assembly

11

Changing the ACU+ LVD Control Level for a Contactor

14

CHAPTER 4. TROUBLESHOOTING AND REPAIR

15

Contact Information

15

Controller, Rectifiers, and Optional Converters

15

ACU+ Controller Configuration

15

System Troubleshooting Information

15

Replacement Information

18

Replacement Procedures

18

Replacing a Rectifier or Converter Module

18

Replacing the ACU+ Controller

18

Replacing a Distribution Device

19

Circuit Card Replacement Procedures

30

Replacing a Distribution Panel

44

Replacing a Battery or Load Disconnect Contactor

47

REVISION RECORD

52

Table of Contents

Page i

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Image 3
Contents UM581127000 Issue AB, March 22 User InstructionsSPEC. NO. Model 581127000 710NPBA Page Table of Contents AC Input Voltages DC Input/Output Voltages General SafetyBattery VoltagesCircuit Card Handling Static Warning USB Drive with All Customer Documentation Bound System Installation ManualCustomer Documentation Package System DescriptionRectifier Modules Module Mounting AssemblyDistribution Cabinet ACU+ Advanced Control Unit Plus ControllerEstop Function Local Controls and IndicatorsRefer to Figure Operating Procedures CONTROLLER, RECTIFIERS, and Optional ConvertersIB2 Circuit Card Locations Operating ProceduresSystem Interface Circuit Card Optional LVD Driver Circuit Card Optional LVD Driver Circuit Card P/N Operating ProceduresOptional LVD Driver Lite Circuit Card Middle Position Normal Operation Optional Manual Battery Disconnect Circuit CardSystem Maintenance Procedures Installers connectionsMaintenance Procedures to be Performed at 6-Month Intervals Procedure User Instructions Issue AB, March 22 Spec. No Model 710NPBAInstalling a Field Expansion Module Mounting Assembly User Instructions Spec. No Model 710NPBA Communications Cables Maintenance Spec. No Model 710 Npba Issue AB, March 22Changing the ACU+ LVD Control Level for a Contactor Contact Information ACU+ Controller ConfigurationSystem Troubleshooting Information Troubleshooting Alarm Conditions on the ACU+ ControllerProcedure Clearing a Converter Lost Alarm Clearing a Rectifier Lost AlarmReplacing the ACU+ Controller Replacement InformationReplacement Procedures Replacing a Rectifier or Converter ModuleDistribution Fuse Alarm Fuse Replacement Replacing a Distribution DeviceGeneral Fuseholder Assembly Replacing a TPS/TLS Fuse ProcedureReplacing a Bullet Nose Fuseholder Procedure On distribution panel Replacing a Bullet Nose Circuit Breaker ProcedureInsert these terminals Into corresponding socketsReplacing a TPH Fuse Procedure Replacing a TPL-B Fuse Troubleshooting and Repair Replacing a GJ/218 Circuit Breaker Procedure Installing Circuit Breaker Pole breaker shown Pole and 4-pole breakers similar List AC Only List BC Only Circuit Card Replacement Procedures Issue AB, March 22 Spec. No Model 710 NpbaSystem Interface Circuit Card Replacement Procedure UM581127000 TB2 Spec. No Model 710NPBA Issue AB, March 22 Relay Optional EIB Interface Board Assembly Top View SM-DU+ and Shunt Interface Assembly Replacement Procedure UM581127000 SM-DU+ Spec. No Model 710NPBA Issue AB, March 22 UM581127000 UM581127000 User Instructions Issue AB, March 22 Spec. No Model 710NPBA UM581127000 Replacing a Distribution Panel Procedure Removing the Distribution PanelInstalling the Distribution Panel Replacing a Distribution Panel Troubleshooting and Repair Restarting the Power System Replacing a Battery or Load Disconnect ContactorProcedure Removing the Contactor Installing the Replacement ContactorWhite/Black Wire Spec. No Model 710 Npba Issue AB, March 22 Black Wire Load Disconnect LLP215523 New LLP216783 Misc. updates Revision Record Change Issue Number Description of ChangeAnswers technical product and system NetPerform Optimization ServicesDownload service & maintenance reports Online For More Information