CHAPTER 4.

TROUBLESHOOTING AND REPAIR

CONTACT INFORMATION

Support contact information is provided on the inside of the back cover of this document.

CONTROLLER, RECTIFIERS, AND OPTIONAL CONVERTERS

For troubleshooting and repair instructions on these units, refer to the following documents.

ACU+ Controller User Instructions (UM1M820BNA)

Rectifier User Instructions (UM1R243000)

Converter User Instructions (UM1C24481500)

ACU+ CONTROLLER CONFIGURATION

If any ACU+ Controller configuration settings were changed, refer to the ACU+ User Instructions (UM1M820BNA) and save a copy of the configuration file. This file can be used to restore the ACU+ Controller settings, if required, at a later date.

Note that provided on a USB drive furnished with the system is an ACU+ configuration drawing (C-drawing) and the ACU+ configuration files loaded into the ACU+ as shipped.

SYSTEM TROUBLESHOOTING INFORMATION

This system is designed for ease in troubleshooting and repair. The various indicators as described in CHAPTER 2. OPERATING PROCEDURES and in the Controller, Rectifier, and Converter User Instructions are designed to isolate failure to a specific element. Once the faulty element has been identified, refer to Replacement Informationand "Replacement Procedures" in this chapter.

Troubleshooting Alarm Conditions on the ACU+ Controller

The ACU+ Controller displays alarm conditions as listed in the Available Alarms section of the ACU+ User Instructions (UM1M820BNA). Programmable external alarm relays are also available. Refer to the System Installation Instructions (IM581127000) and the configuration drawing (C-drawing) supplied with your power system documentation for your alarm relay configurations.

The ACU+’s Active Alarm and Alarm History submenus allow the user to view alarm details. Refer to the ACU+ User Instructions (UM1M820BNA) to access these menus.

Checking the ACU+ Current Limit Point after Adding or Removing a Rectifier

If a rectifier is added to the power system, the system current limit point will automatically increase by the percentage each existing rectifier was set to provide prior to the addition.

If a rectifier is removed from the system (and the Rect Comm Fail alarm is reset), the current limit point will remain unchanged unless the capacity of the remaining rectifiers is not sufficient to maintain the present current limit point. If that happens, the current limit point will automatically increase to the maximum (121% of the remaining rectifiers).

It is recommended that the current limit point be checked whenever a rectifier is added to or removed from the power system.

Chapter 4. Troubleshooting and Repair

Page 15

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Image 21
Contents UM581127000 Issue AB, March 22 User InstructionsSPEC. NO. Model 581127000 710NPBA Page Table of Contents Battery General SafetyVoltages AC Input Voltages DC Input/Output VoltagesCircuit Card Handling Static Warning Customer Documentation Package Bound System Installation ManualSystem Description USB Drive with All Customer DocumentationDistribution Cabinet Module Mounting AssemblyACU+ Advanced Control Unit Plus Controller Rectifier ModulesRefer to Figure Operating Procedures Local Controls and IndicatorsCONTROLLER, RECTIFIERS, and Optional Converters Estop FunctionIB2 Circuit Card Locations Operating ProceduresSystem Interface Circuit Card Optional LVD Driver Circuit Card Optional LVD Driver Circuit Card P/N Operating ProceduresOptional LVD Driver Lite Circuit Card Middle Position Normal Operation Optional Manual Battery Disconnect Circuit CardSystem Maintenance Procedures Installers connectionsMaintenance Procedures to be Performed at 6-Month Intervals Procedure User Instructions Issue AB, March 22 Spec. No Model 710NPBAInstalling a Field Expansion Module Mounting Assembly User Instructions Spec. No Model 710NPBA Communications Cables Maintenance Spec. No Model 710 Npba Issue AB, March 22Changing the ACU+ LVD Control Level for a Contactor System Troubleshooting Information ACU+ Controller ConfigurationTroubleshooting Alarm Conditions on the ACU+ Controller Contact InformationProcedure Clearing a Converter Lost Alarm Clearing a Rectifier Lost AlarmReplacement Procedures Replacement InformationReplacing a Rectifier or Converter Module Replacing the ACU+ ControllerDistribution Fuse Alarm Fuse Replacement Replacing a Distribution DeviceGeneral Fuseholder Assembly Replacing a TPS/TLS Fuse ProcedureReplacing a Bullet Nose Fuseholder Procedure Insert these terminals Replacing a Bullet Nose Circuit Breaker ProcedureInto corresponding sockets On distribution panelReplacing a TPH Fuse Procedure Replacing a TPL-B Fuse Troubleshooting and Repair Replacing a GJ/218 Circuit Breaker Procedure Installing Circuit Breaker Pole breaker shown Pole and 4-pole breakers similar List AC Only List BC Only Circuit Card Replacement Procedures Issue AB, March 22 Spec. No Model 710 NpbaSystem Interface Circuit Card Replacement Procedure UM581127000 TB2 Spec. No Model 710NPBA Issue AB, March 22 Relay Optional EIB Interface Board Assembly Top View SM-DU+ and Shunt Interface Assembly Replacement Procedure UM581127000 SM-DU+ Spec. No Model 710NPBA Issue AB, March 22 UM581127000 UM581127000 User Instructions Issue AB, March 22 Spec. No Model 710NPBA UM581127000 Replacing a Distribution Panel Procedure Removing the Distribution PanelInstalling the Distribution Panel Replacing a Distribution Panel Troubleshooting and Repair Procedure Removing the Contactor Replacing a Battery or Load Disconnect ContactorInstalling the Replacement Contactor Restarting the Power SystemWhite/Black Wire Spec. No Model 710 Npba Issue AB, March 22 Black Wire Load Disconnect LLP215523 New LLP216783 Misc. updates Revision Record Change Issue Number Description of ChangeDownload service & maintenance reports Online NetPerform Optimization ServicesFor More Information Answers technical product and system