5-4 Stand-Alone Power Managers & Digital Power Meters

Connectivity Module

Detail Screen for Power Managers connected to a Circuit Breaker

CB icon appears if

The Detail

Screen for Power Managers shows energy levels, power

measurements, settings, discrete I/O status, and other status information.

Power Manager

 

 

 

address is set to 52.

Settings

PM name

PM location

 

 

 

 

Energy levels

Power measurements

Discrete Input / Output

Actual voltage, current, andname & status information power readings from the PM.

Detail Screen for Digital Power Meters connected to a Circuit Breaker

CB icon appears if

The Detail Screen for Digital Power Meters shows energy levels, power

measurements, settings, discrete I/O status, and other status information.

Digital Power Meter

 

 

 

address is set to 52.

Settings

DPM name

DPM location

 

Energy levels

Power measurements

Discrete Input / Output

Actual voltage, current, andname & status information power readings from the DPM.

Image 26
Contents Connectivity Module 381333-367 CPrerequisites Who Should Use this Installation ManualIi Welcome Connectivity Module Important informationCheck the DIP Switch Settings for RS485 SpecificationsInstallation Overview DIP Switch on bottom of unitIv Outline and Mounting Drawing Connectivity Module Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Vii Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Connectivity Module Status LEDs LED Description LED Function / Mode of OperationStatus LEDs Installation How to Install the Connectivity Module on Asco 940/962 ATSsConnectivity Module Installation How to Test Communication to the Connectivity ModuleHttp//169.254.1.1/config.htm Installation Connectivity ModuleConnectivity Module server Configuration left side Device Configurator Screen for 7000 & 4000 Series ATSsGroup 5 Controller Configuration right side Device Configurator Screen for 7000 & 4000 Series ATSs7000 & 4000 Series ATSs Connectivity Module Power Manager or Power Meter ConfigurationInput Name & Output Names Power Manager only Accessory 85 Descriptive Tags Assigned Detail Screen for 7000 & 4000 Series ATSs Device Configurator Screen for Series 300 ATSs Device Configurator Screen for Series 300 ATSsGroup 1 Controller Configuration right side Connectivity Module Series 300 ATSsPower Meter Series 300 ATSs Connectity ModuleDetail Screen for Series 300 ATSs with a Power Manager Detail Screen for Series 300 ATSsPage Device Configurator Screen without Power Manager Device Configurator Screen for Asco 940/962 ATSsGroup 7A Controller Configuration right side Device Configurator Screen with Power ManagerAsco 940/962 ATSs Connectivity Module Detail Screen for Asco 940/962 ATSs with a Power ManagerDetail Screen for Asco 940/962 ATSs Input names Display Input & Output Names screen Output names Detail Screen for Power Managers connected to a Load Detail Screen for Digital Power Meters connected to a LoadDetail Screen for Power Managers connected to a Generator Detail Screen for PowerDetail On Local Area Connection Properties screen Select All Programs Accessories Command Prompt Connectivity Module Troubleshooting A-3 Problem CauseThird Party Modbus Device Configuration Read RequestsConnectivity Module Snmp Internet-standard Protocol A-5 Snmp Trap messagesProblem Cause Solution Snmp Internet-standard Protocol Connectivity ModuleCatalog No Address set ATS Controller PM or DPM Row IP Address Subnet Mask GatewaySerial No Communication Address Form for Connectivity Module CM Communication Address Form for Connectivity Module CM Index