Emerson 5100 Device Configurator Screen for Series 300 ATSs, Connectivity Module Series 300 ATSs

Page 17

Connectivity Module

Series 300 ATSs 3-1

Device Configurator Screen for Series 300 ATSs

The Device Configurator Screen for Series 300 ATSs shows the Group 1 controller configuration settings (right side) and the Connectivity Module (server) configuration settings (left side) for the selected ATS.

Group 1 Controller Configuration (right side)

Enter or change the ATS Name (8 char. max.) and the ATS Location (20 char. max.). Press the Update button when finished to save the Group 1 controller configuration changes.

Connectivity Module (server) Configuration (left side)

Several configuration settings must be set appropriately as described below. Press the Update Server button when finished to save configuration changes.

Consult with your network administrator for these 4 settings:

IP Address

Subnet Mask

Gateway Address

TCP Port Number

(Range of ports allowed is:

1024-65535, but do not use

ports 14000-14009 or 30718)

Serial Port Speed 9600 Flow Control No flow control Interface Mode RS485-4 or 2 Wire

Encyrption enable check box and assign an AES port (same range as TCP port but do not use the same port number used for TCP port.)

ATS Name

ATS Location

Press Update button when finished to save the configuration changes. Do this before you press Update Server button.

After Controller or has been updated, press Update Server button to save the configuration changes.

SNMP refer to Appendix A-5

Device Configurator Screen for Series 300 ATSs

When a Power Manager or Digital Power Meter is connected, additional buttons appear at the bottom of the Connectivity Module Device Configuration screen.

Press to configure the Power Manager or Digital Power Meter.

Press to configure the Group 1 Controller.

After Controller, PM, or DPM has been updated, press Update Server button to save the configuration changes.

Additional Buttons on Device Configurator Screen for

Series 300 ATSs with Power Manager or Digital Power Meter

Image 17
Contents 381333-367 C Connectivity ModuleIi Welcome Connectivity Module Who Should Use this Installation ManualPrerequisites Important informationInstallation Overview SpecificationsCheck the DIP Switch Settings for RS485 DIP Switch on bottom of unitIv Outline and Mounting Drawing Connectivity Module Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Vii Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Connectivity Module Status LEDs LED Description LED Function / Mode of OperationStatus LEDs How to Install the Connectivity Module on Asco 940/962 ATSs InstallationHow to Test Communication to the Connectivity Module Connectivity Module InstallationInstallation Connectivity Module Http//169.254.1.1/config.htmGroup 5 Controller Configuration right side Device Configurator Screen for 7000 & 4000 Series ATSsConnectivity Module server Configuration left side Device Configurator Screen for 7000 & 4000 Series ATSs7000 & 4000 Series ATSs Connectivity Module Power Manager or Power Meter ConfigurationInput Name & Output Names Power Manager only Accessory 85 Descriptive Tags Assigned Detail Screen for 7000 & 4000 Series ATSs Group 1 Controller Configuration right side Device Configurator Screen for Series 300 ATSsDevice Configurator Screen for Series 300 ATSs Connectivity Module Series 300 ATSsSeries 300 ATSs Connectity Module Power MeterDetail Screen for Series 300 ATSs Detail Screen for Series 300 ATSs with a Power ManagerPage Group 7A Controller Configuration right side Device Configurator Screen for Asco 940/962 ATSsDevice Configurator Screen without Power Manager Device Configurator Screen with Power ManagerAsco 940/962 ATSs Connectivity Module Detail Screen for Asco 940/962 ATSs with a Power ManagerDetail Screen for Asco 940/962 ATSs Input names Display Input & Output Names screen Output names Detail Screen for Digital Power Meters connected to a Load Detail Screen for Power Managers connected to a LoadDetail Screen for Power Detail Screen for Power Managers connected to a GeneratorDetail On Local Area Connection Properties screen Select All Programs Accessories Command Prompt Problem Cause Connectivity Module Troubleshooting A-3Read Requests Third Party Modbus Device ConfigurationSnmp Trap messages Connectivity Module Snmp Internet-standard Protocol A-5Snmp Internet-standard Protocol Connectivity Module Problem Cause SolutionCatalog No Address set ATS Controller PM or DPM Row IP Address Subnet Mask GatewaySerial No Communication Address Form for Connectivity Module CM Communication Address Form for Connectivity Module CM Index