Emerson 5100 Who Should Use this Installation Manual, Ii Welcome Connectivity Module

Page 2

ii Welcome

Connectivity Module

Who Should Use this Installation Manual

This manual for the Connectivity Module should be used to assist individuals who will:

 

 

• install the Connectivity Module (mount and wire)

 

 

• configure the Connectivity Module

 

 

 

• enter in information about your Automatic Transfer Switches

 

 

(7000 & 4000 Series, Series 300, ASCO 940,962,436,434,447,448)

 

 

• use Ethernet access to monitor Connectivity Module (connected devices)

Prerequisites

A working knowledge of Windows XP ® and Windows Internet Explorer 6.0 or higher

 

 

(with Microsoft Virtual Machine or the latest version of the Java Runtime Environment

 

 

loaded) is necessary to configure the Connectivity Module.

Important information

To properly set up the software, you will need the nameplate data and other

that you will need

 

information from all your Automatic Transfer Switches including:

 

 

• ATS Name (your designation for the ATS)

 

 

• ATS Location (where the ATS is located in the building)

 

 

• Voltage Rating, Ampere Rating, and number of Poles for each ATS

 

 

• Catalog No. and Serial No. of each ATS

 

 

• Type of ATS (ATS or ATS/BP [ATS with bypass-isolation switch])

 

 

• Device Address (set in each ATS, Power Manager , or Digital Power Meter)

 

 

 

 

 

 

 

Product

 

Manuals that you may need

7000 & 4000 Series ATS & Group 5 Controller

 

381333-126 & appropriate ATS manual

Series 300, ASCO 940, 962, 436, 434, 447, 448 ATS

 

appropriate ATS manual

Power Manager Xp, Catalog 5220D, 5220T

 

381333-199

Digital Power Meter, Catalog 5210

 

381333-368

Serial Module, Catalog 5110 (Acc. 72A)

 

381333-240

ATS Remote Annunciator, Catalog 5310 (1 channel)

 

381333-316 & 381333-317

ATS Remote Annunciator, Catalog 5350 (8 channel)

 

381333-314 & 381333-315

ATS Remote Annunciator kits 8 channel K871966-004, 1 channel K871966-005

Kits include: ATS Remote Annunciator (RA), Connectivity Module (CM), power supply, mounting hardware, connecting cable The CM can be configured to provide ATS data to ATS Remote Annunciators (RA) over Ethernet either on encryption disabled or enabled mode. Details on how to configure all required parameters for the two modes are in the RA manuals listed above.

Encryption disabled mode is the default operation mode for both the CM and the RA. In this mode, the TCP port and protocol assigned must be the same for both devices.

Encryption enabled mode is when both the CM and RA are configured for AES 128-bit encryption/decryption communication. In this mode, the AES mode and AES port settings in the CM are enabled and assigned a value respectively. Note that the AES port value must be different from the TCP port value (see screen on page 2-1).

Likewise, in the RA, encryption must be enabled and the TCP port is assigned with the same value as the AES port of the CM. Note that the encryption works only on RAs with software version -003 or higher (refer to Configuration, Annunciator screen).

Tip Ö

Communication Address form is included at the back to help you fill in needed information on your

 

Connectivity Modules, ATSs, Power Managers, Digital Power Meters.

The Connectivity Module provides Ethernet-access that allows users to view data from ASCO automatic transfer switches, Power Managers, and Digital Power Meters. All users must follow these precautions:

!DANGER

NOTICE

To avoid possible shock, burns, or death, deenergize all electrical sources to the ATS before installing the Connectivity Module.

Be sure that Users to whom you give access are those persons that you want to view information about the electrical system.

Windows and Internet Explorer are registered trademarks of Microsoft Corporation.

Image 2
Contents Connectivity Module 381333-367 CPrerequisites Who Should Use this Installation ManualIi Welcome Connectivity Module Important informationCheck the DIP Switch Settings for RS485 SpecificationsInstallation Overview DIP Switch on bottom of unitIv Outline and Mounting Drawing Connectivity Module Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Vii Wiring Diagrams Connectivity Module Connectivity Module Wiring Diagrams Connectivity Module Status LEDs LED Description LED Function / Mode of OperationStatus LEDs Installation How to Install the Connectivity Module on Asco 940/962 ATSsConnectivity Module Installation How to Test Communication to the Connectivity ModuleHttp//169.254.1.1/config.htm Installation Connectivity ModuleConnectivity Module server Configuration left side Device Configurator Screen for 7000 & 4000 Series ATSsGroup 5 Controller Configuration right side Device Configurator Screen for 7000 & 4000 Series ATSs7000 & 4000 Series ATSs Connectivity Module Power Manager or Power Meter ConfigurationInput Name & Output Names Power Manager only Accessory 85 Descriptive Tags Assigned Detail Screen for 7000 & 4000 Series ATSs Device Configurator Screen for Series 300 ATSs Device Configurator Screen for Series 300 ATSsGroup 1 Controller Configuration right side Connectivity Module Series 300 ATSsPower Meter Series 300 ATSs Connectity ModuleDetail Screen for Series 300 ATSs with a Power Manager Detail Screen for Series 300 ATSsPage Device Configurator Screen without Power Manager Device Configurator Screen for Asco 940/962 ATSsGroup 7A Controller Configuration right side Device Configurator Screen with Power ManagerAsco 940/962 ATSs Connectivity Module Detail Screen for Asco 940/962 ATSs with a Power ManagerDetail Screen for Asco 940/962 ATSs Input names Display Input & Output Names screen Output names Detail Screen for Power Managers connected to a Load Detail Screen for Digital Power Meters connected to a LoadDetail Screen for Power Managers connected to a Generator Detail Screen for PowerDetail On Local Area Connection Properties screen Select All Programs Accessories Command Prompt Connectivity Module Troubleshooting A-3 Problem CauseThird Party Modbus Device Configuration Read RequestsConnectivity Module Snmp Internet-standard Protocol A-5 Snmp Trap messagesProblem Cause Solution Snmp Internet-standard Protocol Connectivity ModuleCatalog No Address set ATS Controller PM or DPM Row IP Address Subnet Mask GatewaySerial No Communication Address Form for Connectivity Module CM Communication Address Form for Connectivity Module CM Index