Emerson ATCA-7350 manual LAN Device Commands, System Boot Options Parameter #99

Page 21

LAN Device Commands

Supported Commands

 

 

There is no Set Selector or Block Selector with this command.

The System Boot Options parameter #98 is non-volatile. Its parameter data remains preserved after IPMC power cycles and firmware upgrades.

2.1.7.1.4System Boot Options #99

This parameter is an Emerson-specific OEM parameter. It is used to enable or disable BIOS and FRU write protection

Table 2-12 System Boot Options Parameter #99

Boot Option Parameter

 

Data

Description

 

 

1

This parameter enables/disables BIOS and FRU write protection:

 

[7:4] Bios ID (0= Boot Bank A, 1= Boot Bank B, 2= FRU information,

 

others reserved)

 

[3:0] write protect enable/disable (0= disable, 1= enable, others reserved)

 

 

There is no Set Selector or Block Selector with this command. The Boot Option parameter data returned with the IPMI command Get System Boot Options provides the write protect status of the two BIOS flashes and of the FRU information (one byte for each instance).

2.1.8LAN Device Commands

Table 2-13 Supported LAN Device Commands

Command

NetFn (Request/Response)

CMD

 

 

 

Set LAN Configuration Parameters

0x0C/0x0D

0x01

 

 

 

Get LAN Configuration Parameters

0x0C/0x0D

0x02

 

 

 

Set SOL Configuration Parameters

0x0C/0x0D

0x21

 

 

 

Get SOL Configuration Parameters

0x0C/0x0D

0x22

 

 

 

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

21

Image 21
Contents ATCA-7350 Control via Ipmi Contact Address Contents Contents SOL Module ConfigurationList of Tables Response Data of Set Serial Output CommandList of Tables Overview of Contents About this ManualAbbreviations About this Manual Abbreviation Definition ConventionsNotation Description BoldComments and Suggestions Summary of ChangesAbout this Manual Part Number Publication Date DescriptionAbout this Manual 1 HPM.1 Specific Firmware Upgrades Feature DescriptionFeatures IntroductionIntroduction HPM.1 Specific Firmware Upgrades Ipmc Firmware UpgradeSerial over LAN Graceful Shutdown TimeoutSensors MAC Address RecordLocal System Event Log Boot Configuration ParametersExternal Watchdog Introduction Local System Event LogStandard Ipmi Commands Supported CommandsGlobal Ipmi Commands System Interface CommandsSEL Device Commands Watchdog CommandsSupported Watchdog Commands Supported SEL Device CommandsSensor Device Commands FRU Inventory CommandsSupported FRU Inventory Commands Supported Sensor Device CommandsSupported Chassis Device Commands Chassis Device CommandsConfigurable System Boot Option Parameters Supported Commands Chassis Device CommandsSystem Boot Options Parameter #5 Chassis Device Commands Supported CommandsData Byte Description 10 System Boot Options Parameter #96 11 System Boot Options Parameter #98Boot Option Parameter Data Description 12 System Boot Options Parameter #99 LAN Device Commands13 Supported LAN Device Commands LAN Device Commands Supported CommandsPicmg 3.0 Commands 14 Supported Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands Serial Output Commands Emerson Specific Commands15 Serial Output Commands Emerson Specific CommandsSupported Commands17 Response Data of Set Serial Output Command 16 Request Data of Set Serial Output CommandSupported Commands Serial Output Commands Byte Data Field18 Request Data of Get Serial Output Command 19 Response Data of Get Serial Output CommandSerial Output Commands Supported Commands Page FRU Information and Sensor Data Records Area Description Value AccessFRU Information MAC Address RecordEmerson MAC Address Record Emerson MAC Address DescriptorInterface Type Assignments Sensor Data Records Ipmi Sensors OverviewSensor Data Records FRU Information and Sensor Data Records Feature Raw Value Description +12VCC Sensor+3.3VCC Sensor Sensor Data RecordsFRU Information and Sensor Data Records +3.3VSB SensorFRU Information and Sensor Data RecordsSensor Data Records +5VCC Sensor10 +5VSB Sensor 12 -48V Power2 Sensor 11 -48V Power1 Sensor13 Acpi State Sensor 15 BMC Post Error Sensor 14 Bios Bank Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 19 CPU1 Core Rem Sensor 18 CPU0 Status Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 23 FRU Hot Swap Sensor 22 FBD Inlet Temp Sensor24 FW Progress Sensor 26 HD Env Temp Sensor 25 Handle State Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 30 RTM Handle Sensor 29 PwrOk Sig. Drop Sensor31 RTM HS Sensor 33 Ver Change Sensor 32 System Restart Sensor34 Watchdog Sensor 34 Watchdog Sensor Page SOL Module Configuration Configure the SOLIntroduction SOL Module Configuration Enable SOL Load Enable SOL LoadSetup SOL Session Query the Configuration of SOLSetup SOL Session SOL Module Configuration =OEM SOL Module Configuration Query the Configuration of SOLConfigure the SOL Module in OS SOL Module Configuration Configure the SOL Module in OSPage Related Specifications Emerson Network Power Embedded Computing DocumentsTable A-2 Related Specifications Related Documentation