Emerson ATCA-7350 manual Bios Bank Sensor, BMC Post Error Sensor

Page 36

FRU Information and Sensor Data RecordsSensor Data Records

Table 3-14 BIOS Bank Sensor

Feature

Raw Value

Description

 

 

 

Sensor Name

BIOS Bank

-

 

 

 

Sensor LUN

0x00

-

 

 

 

Sensor Number

0x19

-

 

 

 

Entity ID

0xA0

PICMG Front Board

 

 

 

Sensor Type

0xD2

Emerson-specific Discrete Digital

 

 

 

Event/Reading Type

0x6F

Discrete (sensor-specific)

 

 

 

Assertion Event Mask(Byte 15)

0x0F

-

 

 

 

Assertion Event Mask(Byte 16)

0x00

-

 

 

 

Assertion Events

-

-

 

 

 

-

Sensor Offset: 0

Last Boot from BIOS Bank A

 

 

 

-

Sensor Offset: 1

Last Boot from BIOS Bank B

 

 

 

Deassertion Event Mask(Byte 17)

0x00

-

 

 

 

Deassertion Event Mask(Byte 18)

0x00

-

 

 

 

Threshold Mask(Byte 19)

0x0F

-

 

 

 

Threshold Mask(Byte 20)

0x00

-

 

 

 

Base Unit

0x00

(unspecified)

 

 

 

Rearm mode

0x01

Auto

 

 

 

Hysteresis Support

0x00

No Hysteresis or unspecified

 

 

 

Threshold Access Support

0x00

No Thresholds

 

 

 

Event Message Control

0x00

Per Threshold / Discrete State

 

 

 

Reading Definition

-

-

 

 

 

Table 3-15 BMC POST ERROR Sensor

 

Feature

Raw Value

Description

 

 

 

 

 

 

 

Sensor Name

BMC POST ERROR

-

 

 

 

 

 

 

 

Sensor LUN

0x00

-

 

 

 

 

 

 

 

Sensor Number

0x1A

-

 

 

 

 

 

 

 

Entity ID

0xA0

PICMG Front Board

 

 

 

 

 

 

 

Sensor Type

0x28

Management Subsystem Health

 

 

 

 

 

 

 

Event/Reading Type

0x6F

Discrete (sensor-specific)

 

 

 

 

 

 

 

Assertion Event Mask(Byte 15)

0x31

-

 

 

 

 

 

 

 

Assertion Event Mask(Byte 16)

0x00

-

 

 

 

 

 

 

 

Assertion Events

-

-

 

 

 

 

 

 

 

-

Event Offset: 0

Sensor access degraded or

 

 

 

 

unavailable

 

 

 

 

 

 

 

-

Event Offset: 4

Sensor failure

 

 

 

 

 

 

 

 

 

 

 

36

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

Image 36
Contents ATCA-7350 Control via Ipmi Contact Address Contents SOL Module Configuration ContentsResponse Data of Set Serial Output Command List of TablesList of Tables Overview of Contents About this ManualAbbreviations Conventions About this Manual Abbreviation DefinitionNotation Description BoldSummary of Changes Comments and SuggestionsAbout this Manual Part Number Publication Date DescriptionAbout this Manual Feature Description 1 HPM.1 Specific Firmware UpgradesFeatures IntroductionIpmc Firmware Upgrade Introduction HPM.1 Specific Firmware UpgradesGraceful Shutdown Timeout Serial over LANSensors MAC Address RecordBoot Configuration Parameters Local System Event LogExternal Watchdog Introduction Local System Event LogSupported Commands Standard Ipmi CommandsGlobal Ipmi Commands System Interface CommandsWatchdog Commands SEL Device CommandsSupported Watchdog Commands Supported SEL Device CommandsFRU Inventory Commands Sensor Device CommandsSupported FRU Inventory Commands Supported Sensor Device CommandsChassis Device Commands Supported Chassis Device CommandsConfigurable System Boot Option Parameters Supported Commands Chassis Device CommandsSystem Boot Options Parameter #5 Chassis Device Commands Supported CommandsData Byte Description 10 System Boot Options Parameter #96 11 System Boot Options Parameter #98Boot Option Parameter Data Description LAN Device Commands 12 System Boot Options Parameter #9913 Supported LAN Device Commands LAN Device Commands Supported CommandsPicmg 3.0 Commands 14 Supported Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands Emerson Specific Commands Serial Output Commands15 Serial Output Commands Emerson Specific CommandsSupported Commands16 Request Data of Set Serial Output Command 17 Response Data of Set Serial Output CommandSupported Commands Serial Output Commands Byte Data Field18 Request Data of Get Serial Output Command 19 Response Data of Get Serial Output CommandSerial Output Commands Supported Commands Page Area Description Value Access FRU Information and Sensor Data RecordsFRU Information MAC Address RecordEmerson MAC Address Record Emerson MAC Address DescriptorInterface Type Assignments Sensor Data Records Ipmi Sensors OverviewSensor Data Records FRU Information and Sensor Data Records Feature Raw Value Description +12VCC Sensor+3.3VCC Sensor +3.3VSB Sensor Sensor Data RecordsFRU Information and Sensor Data Records+5VCC Sensor FRU Information and Sensor Data RecordsSensor Data Records10 +5VSB Sensor 11 -48V Power1 Sensor 12 -48V Power2 Sensor13 Acpi State Sensor 14 Bios Bank Sensor 15 BMC Post Error Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 18 CPU0 Status Sensor 19 CPU1 Core Rem Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 22 FBD Inlet Temp Sensor 23 FRU Hot Swap Sensor24 FW Progress Sensor 25 Handle State Sensor 26 HD Env Temp Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 29 PwrOk Sig. Drop Sensor 30 RTM Handle Sensor31 RTM HS Sensor 32 System Restart Sensor 33 Ver Change Sensor34 Watchdog Sensor 34 Watchdog Sensor Page SOL Module Configuration Configure the SOLIntroduction Enable SOL Load SOL Module Configuration Enable SOL LoadSetup SOL Session Query the Configuration of SOLSetup SOL Session SOL Module Configuration SOL Module Configuration Query the Configuration of SOL =OEMConfigure the SOL Module in OS Configure the SOL Module in OS SOL Module ConfigurationPage Emerson Network Power Embedded Computing Documents Related SpecificationsTable A-2 Related Specifications Related Documentation