SOL Module Configuration | Enable SOL Load |
|
|
"90" is the IPMB address of the blade.
The IP addresses of the two channels cannot be set to be in the same network segment. Otherwise, the settings fail.
2.Set the subnet mask of the two channels.
Use the command Set LAN Configuration Parameters of IPMI2.0 with Parameter selector of 6.
The value of Parameter selector is 6.
See table
For example, on Emerson shelf manager, set the subnet masks of both channel 1 and channel 2 to 255.255.0.0.
ipmicmd
3.Set the user name.
Use the command Set User Name of IPMI2.0.
See table
For example, on Emerson shelf manager, set the user name to solusername. ipmicmd
4.Set the password.
Use the command Set User Password of IPMI2.0.
See table
For example, on Emerson shelf manager, set the password to soluserpassword. ipmicmd
5.Set the user right.
Use the command Set User Access Command of IPMI2.0.
For example, on Emerson shelf manager, set the right of user 2 to Administrator (4). ipmicmd
6.Enable the user.
Use the command Set User Password Command of IPMI2.0. For example, on Emerson shelf manager, enable user 2. ipmicmd
4.3Enable SOL Load
Use the command Set SOL Configuration Parameters of IPMI2.0. The value of Parameter selector is 1.
See table
54 |