Emerson ATCA-7350 manual SOL Module Configuration Enable SOL Load

Page 54

SOL Module Configuration

Enable SOL Load

 

 

"90" is the IPMB address of the blade.

The IP addresses of the two channels cannot be set to be in the same network segment. Otherwise, the settings fail.

2.Set the subnet mask of the two channels.

Use the command Set LAN Configuration Parameters of IPMI2.0 with Parameter selector of 6.

The value of Parameter selector is 6.

See table 23-4 in section 23.2 of the IPMI 2.0 specification.

For example, on Emerson shelf manager, set the subnet masks of both channel 1 and channel 2 to 255.255.0.0.

ipmicmd -k "0 90 0 0c 01 01 06 ff ff 00 00" smi 0 ipmicmd -k "0 90 0 0c 01 02 06 ff ff 00 00" smi 0 "90" is the IPMB address of the blade.

3.Set the user name.

Use the command Set User Name of IPMI2.0.

See table 23-32 in section 23.28 of the IPMI 2.0 specification.

For example, on Emerson shelf manager, set the user name to solusername. ipmicmd -k "0 90 0 06 45 02 73 6f 6c 75 73 65 72 6e 61 6d 65" smi 0

4.Set the password.

Use the command Set User Password of IPMI2.0.

See table 23-34 in section 23.30 of the IPMI 2.0 specification.

For example, on Emerson shelf manager, set the password to soluserpassword. ipmicmd -k "0 90 0 06 47 82 02 73 6f 6c 75 73 65 72 70 61 73 73 77 6f 72 64" smi 0

5.Set the user right.

Use the command Set User Access Command of IPMI2.0.

For example, on Emerson shelf manager, set the right of user 2 to Administrator (4). ipmicmd -k "0 90 0 06 43 f1 02 04 00" smi 0

6.Enable the user.

Use the command Set User Password Command of IPMI2.0. For example, on Emerson shelf manager, enable user 2. ipmicmd -k "0 90 0 06 47 82 01" smi 0

4.3Enable SOL Load

Use the command Set SOL Configuration Parameters of IPMI2.0. The value of Parameter selector is 1.

See table 26-3 in section 26.2 of the IPMI 2.0 specification.

54

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

Image 54
Contents ATCA-7350 Control via Ipmi Contact Address Contents SOL Module Configuration ContentsResponse Data of Set Serial Output Command List of TablesList of Tables Overview of Contents About this ManualAbbreviations Notation Description ConventionsAbout this Manual Abbreviation Definition BoldAbout this Manual Summary of ChangesComments and Suggestions Part Number Publication Date DescriptionAbout this Manual Features Feature Description1 HPM.1 Specific Firmware Upgrades IntroductionIpmc Firmware Upgrade Introduction HPM.1 Specific Firmware UpgradesSensors Graceful Shutdown TimeoutSerial over LAN MAC Address RecordExternal Watchdog Boot Configuration ParametersLocal System Event Log Introduction Local System Event LogGlobal Ipmi Commands Supported CommandsStandard Ipmi Commands System Interface CommandsSupported Watchdog Commands Watchdog CommandsSEL Device Commands Supported SEL Device CommandsSupported FRU Inventory Commands FRU Inventory CommandsSensor Device Commands Supported Sensor Device CommandsConfigurable System Boot Option Parameters Chassis Device CommandsSupported Chassis Device Commands Supported Commands Chassis Device CommandsSystem Boot Options Parameter #5 Chassis Device Commands Supported CommandsData Byte Description 10 System Boot Options Parameter #96 11 System Boot Options Parameter #98Boot Option Parameter Data Description 13 Supported LAN Device Commands LAN Device Commands12 System Boot Options Parameter #99 LAN Device Commands Supported CommandsPicmg 3.0 Commands 14 Supported Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands 15 Serial Output Commands Emerson Specific CommandsSerial Output Commands Emerson Specific CommandsSupported CommandsSupported Commands Serial Output Commands 16 Request Data of Set Serial Output Command17 Response Data of Set Serial Output Command Byte Data Field18 Request Data of Get Serial Output Command 19 Response Data of Get Serial Output CommandSerial Output Commands Supported Commands Page FRU Information Area Description Value AccessFRU Information and Sensor Data Records MAC Address RecordEmerson MAC Address Record Emerson MAC Address DescriptorInterface Type Assignments Sensor Data Records Ipmi Sensors OverviewSensor Data Records FRU Information and Sensor Data Records Feature Raw Value Description +12VCC Sensor+3.3VCC Sensor +3.3VSB Sensor Sensor Data RecordsFRU Information and Sensor Data Records+5VCC Sensor FRU Information and Sensor Data RecordsSensor Data Records10 +5VSB Sensor 11 -48V Power1 Sensor 12 -48V Power2 Sensor13 Acpi State Sensor 14 Bios Bank Sensor 15 BMC Post Error Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 18 CPU0 Status Sensor 19 CPU1 Core Rem Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 22 FBD Inlet Temp Sensor 23 FRU Hot Swap Sensor24 FW Progress Sensor 25 Handle State Sensor 26 HD Env Temp Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 29 PwrOk Sig. Drop Sensor 30 RTM Handle Sensor31 RTM HS Sensor 32 System Restart Sensor 33 Ver Change Sensor34 Watchdog Sensor 34 Watchdog Sensor Page SOL Module Configuration Configure the SOLIntroduction Enable SOL Load SOL Module Configuration Enable SOL LoadSetup SOL Session Query the Configuration of SOLSetup SOL Session SOL Module Configuration SOL Module Configuration Query the Configuration of SOL =OEMConfigure the SOL Module in OS Configure the SOL Module in OS SOL Module ConfigurationPage Table A-2 Related Specifications Emerson Network Power Embedded Computing DocumentsRelated Specifications Related Documentation