Emerson ATCA-7350 manual Setup SOL Session, Query the Configuration of SOL

Page 55

Setup SOL Session

SOL Module Configuration

 

 

The value of Parameter selector is 1.

See table 26-5 in section 26.3 of the IPMI 2.0 specification.

On Emerson shelf manager, enable the SOL of channel 1.

ipmicmd -k "0 90 0 0c 21 01 01 01" smi 0

4.4Setup SOL Session

After the previous seven steps, you can set up a session or an SOL connection to the IPMC through IPMITOOL. You can use the commands provided by IPMITOOL to directly configure the SOL for the IPMC.

If a shelf manager supports automatic configuration through the script, you can use the script to configure the SOL directly. For example, in the command line of Emerson shelf manager, run the commands sv_stop and sv_start to restart the script and configure the SOL automatically. After that, you can use the SOL without configuring and modifying it.

4.5Query the Configuration of SOL

Querying the configuration of SOL

To query the configurations, do the following:

1.Query the IP address.

Use the command Get LAN Configuration Parameters. See table 23-3 in section 23.2 of the IPMI 2.0 specification. The value of Parameter selector is 3.

For example, on Emerson shelf manager, query the IP address of channel 1. ipmicmd -k "0 90 0 0c 02 01 03 00 00" smi 0

"90" is the IPMB address of the blade.

2.Query the subnet mask.

Use the command Get LAN Configuration Parameters. The value of Parameter selector is 6.

For example, on Emerson shelf manager, query the subnet mask of channel 1. ipmicmd -k "0 90 0 0c 02 01 06 00 00" smi 0

3.Query the user name.

Use the command Get User Name.

See table 22-33 in section 22.29 of the IPMI 2.0 specification.

For example, on Emerson shelf manager, query the name of the user 2. ipmicmd -k "0 90 0 06 46 02 " smi 0

4.Query the channel information.

Use the command Get Channel Access.

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

55

Image 55
Contents ATCA-7350 Control via Ipmi Contact Address Contents Contents SOL Module ConfigurationList of Tables Response Data of Set Serial Output CommandList of Tables About this Manual Overview of ContentsAbbreviations Bold ConventionsAbout this Manual Abbreviation Definition Notation DescriptionPart Number Publication Date Description Summary of ChangesComments and Suggestions About this ManualAbout this Manual Introduction Feature Description1 HPM.1 Specific Firmware Upgrades FeaturesIntroduction HPM.1 Specific Firmware Upgrades Ipmc Firmware UpgradeMAC Address Record Graceful Shutdown TimeoutSerial over LAN SensorsIntroduction Local System Event Log Boot Configuration ParametersLocal System Event Log External WatchdogSystem Interface Commands Supported CommandsStandard Ipmi Commands Global Ipmi CommandsSupported SEL Device Commands Watchdog CommandsSEL Device Commands Supported Watchdog CommandsSupported Sensor Device Commands FRU Inventory CommandsSensor Device Commands Supported FRU Inventory CommandsSupported Commands Chassis Device Commands Chassis Device CommandsSupported Chassis Device Commands Configurable System Boot Option ParametersChassis Device Commands Supported Commands System Boot Options Parameter #5Data Byte Description 11 System Boot Options Parameter #98 10 System Boot Options Parameter #96Boot Option Parameter Data Description LAN Device Commands Supported Commands LAN Device Commands12 System Boot Options Parameter #99 13 Supported LAN Device Commands14 Supported Picmg 3.0 Commands Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands Emerson Specific CommandsSupported Commands Emerson Specific CommandsSerial Output Commands 15 Serial Output CommandsByte Data Field 16 Request Data of Set Serial Output Command17 Response Data of Set Serial Output Command Supported Commands Serial Output Commands19 Response Data of Get Serial Output Command 18 Request Data of Get Serial Output CommandSerial Output Commands Supported Commands Page MAC Address Record Area Description Value AccessFRU Information and Sensor Data Records FRU InformationEmerson MAC Address Descriptor Emerson MAC Address RecordInterface Type Assignments Ipmi Sensors Overview Sensor Data RecordsSensor Data Records FRU Information and Sensor Data Records +12VCC Sensor Feature Raw Value Description+3.3VCC Sensor Sensor Data RecordsFRU Information and Sensor Data Records +3.3VSB SensorFRU Information and Sensor Data RecordsSensor Data Records +5VCC Sensor10 +5VSB Sensor 12 -48V Power2 Sensor 11 -48V Power1 Sensor13 Acpi State Sensor 15 BMC Post Error Sensor 14 Bios Bank Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 19 CPU1 Core Rem Sensor 18 CPU0 Status Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 23 FRU Hot Swap Sensor 22 FBD Inlet Temp Sensor24 FW Progress Sensor 26 HD Env Temp Sensor 25 Handle State Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 30 RTM Handle Sensor 29 PwrOk Sig. Drop Sensor31 RTM HS Sensor 33 Ver Change Sensor 32 System Restart Sensor34 Watchdog Sensor 34 Watchdog Sensor Page Configure the SOL SOL Module ConfigurationIntroduction SOL Module Configuration Enable SOL Load Enable SOL LoadQuery the Configuration of SOL Setup SOL SessionSetup SOL Session SOL Module Configuration =OEM SOL Module Configuration Query the Configuration of SOLConfigure the SOL Module in OS SOL Module Configuration Configure the SOL Module in OSPage Related Documentation Emerson Network Power Embedded Computing DocumentsRelated Specifications Table A-2 Related Specifications