Emerson ATCA-7350 manual +12VCC Sensor, +3.3VCC Sensor, Feature Raw Value Description

Page 30

FRU Information and Sensor Data Records

Sensor Data Records

 

 

The following tables describe all on-board IPMI sensors in detail.

Table 3-6 +12VCC Sensor

Feature

Raw Value

Description

 

 

 

Sensor Name

+12VCC

-

 

 

 

Sensor LUN

0x00

-

 

 

 

Sensor Number

0x07

-

 

 

 

Entity ID

0xA0

PICMG Front Board

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Event/Reading Type

0x01

Threshold

 

 

 

Assertion Event Mask(Byte 15)

0x95

-

 

 

 

Assertion Event Mask(Byte 16)

0x0A

-

 

 

 

Deassertion Event Mask(Byte 17)

0x95

-

 

 

 

Deassertion Event Mask(Byte 18)

0x0A

-

 

 

 

Threshold Mask(Byte 19)

0x3F

-

 

 

 

Threshold Mask(Byte 20)

0x3F

-

 

 

 

Base Unit

0x04

Volts

 

 

 

Nominal Reading

0xBF

12.03

 

 

 

Upper non-recoverable threshold

0xE9

14.68

 

 

 

Upper critical threshold

0xE0

14.11

 

 

 

Upper non-critical threshold

0xD6

13.48

 

 

 

Lower non-recoverable threshold

0x94

9.32

 

 

 

Lower critical threshold

0x9D

9.89

 

 

 

Lower non-critical threshold

0xA7

10.52

 

 

 

Rearm mode

0x01

Auto

 

 

 

Hysteresis Support

0x02

Readable and Setable

 

 

 

Threshold Access Support

0x02

Readable and Setable

 

 

 

Event Message Control

0x00

Per Threshold / Discrete State

 

 

 

Reading Definition

Analog reading byte

Analog sensor reading

 

 

 

Table 3-7 +3.3VCC Sensor

 

Feature

 

Raw Value

Description

 

 

 

 

 

 

 

 

Sensor Name

 

+3.3VCC

-

 

 

 

 

 

 

 

 

Sensor LUN

 

0x00

-

 

 

 

 

 

 

 

 

Sensor Number

 

0x05

-

 

 

 

 

 

 

 

 

Entity ID

 

0xA0

PICMG Front Board

 

 

 

 

 

 

 

 

Sensor Type

 

0x02

Voltage

 

 

 

 

 

 

 

 

Event/Reading Type

 

0x01

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

Image 30
Contents ATCA-7350 Control via Ipmi Contact Address Contents SOL Module Configuration ContentsResponse Data of Set Serial Output Command List of TablesList of Tables Overview of Contents About this ManualAbbreviations Notation Description ConventionsAbout this Manual Abbreviation Definition BoldAbout this Manual Summary of ChangesComments and Suggestions Part Number Publication Date DescriptionAbout this Manual Features Feature Description1 HPM.1 Specific Firmware Upgrades IntroductionIpmc Firmware Upgrade Introduction HPM.1 Specific Firmware UpgradesSensors Graceful Shutdown TimeoutSerial over LAN MAC Address RecordExternal Watchdog Boot Configuration ParametersLocal System Event Log Introduction Local System Event LogGlobal Ipmi Commands Supported CommandsStandard Ipmi Commands System Interface CommandsSupported Watchdog Commands Watchdog CommandsSEL Device Commands Supported SEL Device CommandsSupported FRU Inventory Commands FRU Inventory CommandsSensor Device Commands Supported Sensor Device CommandsConfigurable System Boot Option Parameters Chassis Device CommandsSupported Chassis Device Commands Supported Commands Chassis Device CommandsSystem Boot Options Parameter #5 Chassis Device Commands Supported CommandsData Byte Description 10 System Boot Options Parameter #96 11 System Boot Options Parameter #98Boot Option Parameter Data Description 13 Supported LAN Device Commands LAN Device Commands12 System Boot Options Parameter #99 LAN Device Commands Supported CommandsPicmg 3.0 Commands 14 Supported Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands 15 Serial Output Commands Emerson Specific CommandsSerial Output Commands Emerson Specific CommandsSupported CommandsSupported Commands Serial Output Commands 16 Request Data of Set Serial Output Command17 Response Data of Set Serial Output Command Byte Data Field18 Request Data of Get Serial Output Command 19 Response Data of Get Serial Output CommandSerial Output Commands Supported Commands Page FRU Information Area Description Value AccessFRU Information and Sensor Data Records MAC Address RecordEmerson MAC Address Record Emerson MAC Address DescriptorInterface Type Assignments Sensor Data Records Ipmi Sensors OverviewSensor Data Records FRU Information and Sensor Data Records Feature Raw Value Description +12VCC Sensor+3.3VCC Sensor +3.3VSB Sensor Sensor Data RecordsFRU Information and Sensor Data Records+5VCC Sensor FRU Information and Sensor Data RecordsSensor Data Records10 +5VSB Sensor 11 -48V Power1 Sensor 12 -48V Power2 Sensor13 Acpi State Sensor 14 Bios Bank Sensor 15 BMC Post Error Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 18 CPU0 Status Sensor 19 CPU1 Core Rem Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 22 FBD Inlet Temp Sensor 23 FRU Hot Swap Sensor24 FW Progress Sensor 25 Handle State Sensor 26 HD Env Temp Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 29 PwrOk Sig. Drop Sensor 30 RTM Handle Sensor31 RTM HS Sensor 32 System Restart Sensor 33 Ver Change Sensor34 Watchdog Sensor 34 Watchdog Sensor Page SOL Module Configuration Configure the SOLIntroduction Enable SOL Load SOL Module Configuration Enable SOL LoadSetup SOL Session Query the Configuration of SOLSetup SOL Session SOL Module Configuration SOL Module Configuration Query the Configuration of SOL =OEMConfigure the SOL Module in OS Configure the SOL Module in OS SOL Module ConfigurationPage Table A-2 Related Specifications Emerson Network Power Embedded Computing DocumentsRelated Specifications Related Documentation