Emerson ATCA-7350 manual SOL Module Configuration, Introduction, Configure the SOL

Page 53

SOL Module Configuration

4

4.1Introduction

This chapter includes the following sections:

zConfigure the SOL

zEnable SOL load

zSetup a SOL session

zQuery the configuration of SOL

zConfigure the SOL mode in OS

4.2Configure the SOL

Before the configuration, the IPMC has no user or IP address, so you cannot connect to the IPMC through IPMITOOL. In this case, you need to use IPMI commands through the IPMB channel of the shelf managers to configure the SOL and set the IPMC.

The IPMB address is the hardware address marked on the shelf multiplied by 2.

Configuring SOL

Perform the following six steps to configure the SOL:

1.Set the IP addresses of the two channels.

Use the command Set LAN Configuration Parameters of IPMI2.0 with Parameter selector of 3.

See table 23-2 in section 23.1 of the IPMI 2.0 specification. The value of Parameter selector is 3.

For example, on Emerson shelf manager, set the IP address of channel 1 to

172.17.10.78and that of channel 2 to 172.18.10.78. ipmicmd -k "0 90 0 0c 01 01 03 ac 11 0a 4e" smi 0 ipmicmd -k "0 90 0 0c 01 02 03 ac 12 0a 4e" smi 0

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

53

Image 53
Contents ATCA-7350 Control via Ipmi Contact Address Contents Contents SOL Module ConfigurationList of Tables Response Data of Set Serial Output CommandList of Tables Abbreviations Overview of ContentsAbout this Manual About this Manual Abbreviation Definition ConventionsNotation Description BoldComments and Suggestions Summary of ChangesAbout this Manual Part Number Publication Date DescriptionAbout this Manual 1 HPM.1 Specific Firmware Upgrades Feature DescriptionFeatures IntroductionIntroduction HPM.1 Specific Firmware Upgrades Ipmc Firmware UpgradeSerial over LAN Graceful Shutdown TimeoutSensors MAC Address RecordLocal System Event Log Boot Configuration ParametersExternal Watchdog Introduction Local System Event LogStandard Ipmi Commands Supported CommandsGlobal Ipmi Commands System Interface CommandsSEL Device Commands Watchdog CommandsSupported Watchdog Commands Supported SEL Device CommandsSensor Device Commands FRU Inventory CommandsSupported FRU Inventory Commands Supported Sensor Device CommandsSupported Chassis Device Commands Chassis Device CommandsConfigurable System Boot Option Parameters Supported Commands Chassis Device CommandsData Byte Description System Boot Options Parameter #5Chassis Device Commands Supported Commands Boot Option Parameter Data Description 10 System Boot Options Parameter #9611 System Boot Options Parameter #98 12 System Boot Options Parameter #99 LAN Device Commands13 Supported LAN Device Commands LAN Device Commands Supported CommandsSupported Commands Picmg 3.0 Commands Picmg 3.0 Commands14 Supported Picmg 3.0 Commands Serial Output Commands Emerson Specific Commands15 Serial Output Commands Emerson Specific CommandsSupported Commands17 Response Data of Set Serial Output Command 16 Request Data of Set Serial Output CommandSupported Commands Serial Output Commands Byte Data FieldSerial Output Commands Supported Commands 18 Request Data of Get Serial Output Command19 Response Data of Get Serial Output Command Page FRU Information and Sensor Data Records Area Description Value AccessFRU Information MAC Address RecordInterface Type Assignments Emerson MAC Address RecordEmerson MAC Address Descriptor Sensor Data Records FRU Information and Sensor Data Records Sensor Data RecordsIpmi Sensors Overview +3.3VCC Sensor Feature Raw Value Description+12VCC Sensor Sensor Data RecordsFRU Information and Sensor Data Records +3.3VSB SensorFRU Information and Sensor Data RecordsSensor Data Records +5VCC Sensor10 +5VSB Sensor 12 -48V Power2 Sensor 11 -48V Power1 Sensor13 Acpi State Sensor 15 BMC Post Error Sensor 14 Bios Bank Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 19 CPU1 Core Rem Sensor 18 CPU0 Status Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 23 FRU Hot Swap Sensor 22 FBD Inlet Temp Sensor24 FW Progress Sensor 26 HD Env Temp Sensor 25 Handle State Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 30 RTM Handle Sensor 29 PwrOk Sig. Drop Sensor31 RTM HS Sensor 33 Ver Change Sensor 32 System Restart Sensor34 Watchdog Sensor 34 Watchdog Sensor Page Introduction SOL Module ConfigurationConfigure the SOL SOL Module Configuration Enable SOL Load Enable SOL LoadSetup SOL Session SOL Module Configuration Setup SOL SessionQuery the Configuration of SOL =OEM SOL Module Configuration Query the Configuration of SOLConfigure the SOL Module in OS SOL Module Configuration Configure the SOL Module in OSPage Related Specifications Emerson Network Power Embedded Computing DocumentsTable A-2 Related Specifications Related Documentation