Emerson ATCA-7350 +3.3VSB Sensor, Sensor Data RecordsFRU Information and Sensor Data Records

Page 31

Sensor Data RecordsFRU Information and Sensor Data Records

Table 3-7 +3.3VCC Sensor (continued)

Feature

Raw Value

Description

 

 

 

Assertion Event Mask(Byte 15)

0x95

-

 

 

 

Assertion Event Mask(Byte 16)

0x0A

-

 

 

 

Deassertion Event Mask(Byte 17)

0x95

-

 

 

 

Deassertion Event Mask(Byte 18)

0x0A

-

 

 

 

Threshold Mask(Byte 19)

0x3F

-

 

 

 

Threshold Mask(Byte 20)

0x3F

-

 

 

 

Base Unit

0x04

Volts

 

 

 

Nominal Reading

0xBF

3.3

 

 

 

Upper non-recoverable threshold

0xD6

3.7

 

 

 

Upper critical threshold

0xD1

3.62

 

 

 

Upper non-critical threshold

0xCC

3.53

 

 

 

Lower non-recoverable threshold

0xA8

2.91

 

 

 

Lower critical threshold

0xAD

2.99

 

 

 

Lower non-critical threshold

0xB1

3.06

 

 

 

Rearm mode

0x01

Auto

 

 

 

Hysteresis Support

0x02

Readable and Setable

 

 

 

Threshold Access Support

0x02

Readable and Setable

 

 

 

Event Message Control

0x00

Per Threshold / Discrete State

 

 

 

Reading Definition

Analog reading byte

Analog sensor reading

 

 

 

Table 3-8 +3.3VSB Sensor

Feature

Raw Value

Description

 

 

 

Sensor Name

+3.3VSB

-

 

 

 

Sensor LUN

0x00

-

 

 

 

Sensor Number

0x09

-

 

 

 

Entity ID

0xA0

PICMG Front Board

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Event/Reading Type

0x01

Threshold

 

 

 

Assertion Event Mask(Byte 15)

0x95

-

 

 

 

Assertion Event Mask(Byte 16)

0x0A

-

 

 

 

Deassertion Event Mask(Byte 17)

0x95

-

 

 

 

Deassertion Event Mask(Byte 18)

0x0A

-

 

 

 

Threshold Mask(Byte 19)

0x3F

-

 

 

 

Threshold Mask(Byte 20)

0x3F

-

 

 

 

Base Unit

0x04

Volts

 

 

 

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

31

Image 31
Contents ATCA-7350 Control via Ipmi Contact Address Contents Contents SOL Module ConfigurationList of Tables Response Data of Set Serial Output CommandList of Tables About this Manual Overview of ContentsAbbreviations Bold ConventionsAbout this Manual Abbreviation Definition Notation DescriptionPart Number Publication Date Description Summary of ChangesComments and Suggestions About this ManualAbout this Manual Introduction Feature Description1 HPM.1 Specific Firmware Upgrades FeaturesIntroduction HPM.1 Specific Firmware Upgrades Ipmc Firmware UpgradeMAC Address Record Graceful Shutdown TimeoutSerial over LAN SensorsIntroduction Local System Event Log Boot Configuration ParametersLocal System Event Log External WatchdogSystem Interface Commands Supported CommandsStandard Ipmi Commands Global Ipmi CommandsSupported SEL Device Commands Watchdog CommandsSEL Device Commands Supported Watchdog CommandsSupported Sensor Device Commands FRU Inventory CommandsSensor Device Commands Supported FRU Inventory CommandsSupported Commands Chassis Device Commands Chassis Device CommandsSupported Chassis Device Commands Configurable System Boot Option ParametersChassis Device Commands Supported Commands System Boot Options Parameter #5Data Byte Description 11 System Boot Options Parameter #98 10 System Boot Options Parameter #96Boot Option Parameter Data Description LAN Device Commands Supported Commands LAN Device Commands12 System Boot Options Parameter #99 13 Supported LAN Device Commands14 Supported Picmg 3.0 Commands Picmg 3.0 CommandsSupported Commands Picmg 3.0 Commands Emerson Specific CommandsSupported Commands Emerson Specific CommandsSerial Output Commands 15 Serial Output CommandsByte Data Field 16 Request Data of Set Serial Output Command17 Response Data of Set Serial Output Command Supported Commands Serial Output Commands19 Response Data of Get Serial Output Command 18 Request Data of Get Serial Output CommandSerial Output Commands Supported Commands Page MAC Address Record Area Description Value AccessFRU Information and Sensor Data Records FRU InformationEmerson MAC Address Descriptor Emerson MAC Address RecordInterface Type Assignments Ipmi Sensors Overview Sensor Data RecordsSensor Data Records FRU Information and Sensor Data Records +12VCC Sensor Feature Raw Value Description+3.3VCC Sensor Sensor Data RecordsFRU Information and Sensor Data Records +3.3VSB SensorFRU Information and Sensor Data RecordsSensor Data Records +5VCC Sensor10 +5VSB Sensor 12 -48V Power2 Sensor 11 -48V Power1 Sensor13 Acpi State Sensor 15 BMC Post Error Sensor 14 Bios Bank Sensor16 Boot Errors Sensor 17 CPU0 Core Rem Sensor 19 CPU1 Core Rem Sensor 18 CPU0 Status Sensor20 CPU1 Status Sensor 21 CPU Inlet Temp Sensor 23 FRU Hot Swap Sensor 22 FBD Inlet Temp Sensor24 FW Progress Sensor 26 HD Env Temp Sensor 25 Handle State Sensor27 Ipmb Link State Sensor 28 Log Disabled Sensor 30 RTM Handle Sensor 29 PwrOk Sig. Drop Sensor31 RTM HS Sensor 33 Ver Change Sensor 32 System Restart Sensor34 Watchdog Sensor 34 Watchdog Sensor Page Configure the SOL SOL Module ConfigurationIntroduction SOL Module Configuration Enable SOL Load Enable SOL LoadQuery the Configuration of SOL Setup SOL SessionSetup SOL Session SOL Module Configuration =OEM SOL Module Configuration Query the Configuration of SOLConfigure the SOL Module in OS SOL Module Configuration Configure the SOL Module in OSPage Related Documentation Emerson Network Power Embedded Computing DocumentsRelated Specifications Table A-2 Related Specifications