Napoleon Fireplaces GD82NT-T manual Night Lighttm Replacement, Operation / Maintenance, Time OUT

Page 19

19

NIGHT LIGHTTM REPLACEMENT

Yo u r comes equipped with our Night LightTM. The light has been pre-wired and is controlled from the remote control.

If in the event the lamp or lens needs to be replaced, follow the instructions below.

GASKET

FIGURE 46

Unplug the wire harness

/transformer from the junction box inside the fi replace or turn off the electrical breaker for the fi replace.

FIGURE 44

LENSE

FRAME

Remove the four screws that secure the lens frame to the top of the fi rebox.

This frame retains the glass lens. The lamp can now be accessed.

LENSE

FRAME

SCREWS

FIREBOX TOP

Note: Do not handle the lamp (bulb) with bare fingers, protect with a clean dry cloth.

The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp and lens are special “high temperature” products.

When re-installing, ensure integrity of gasket seal.

THE FIREBOX MUST BE SEALED.

Over tightening the screws could break the lens.

“Light Leakage” from the upper area may be observed.

The holes in the lamp housing are necessary for

FIGURE 45

ventilation and must not be blocked.

OPERATION / MAINTENANCE

TIME OUT

If the appliance is turned on and the Receiver does not re- ceive any command for 24 hours, it automatically turns the appliance

FIREPLACE OPERATION

To operate this fi rplace using the remote, the pilot must be running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the

auto position.

FIGURE 46

 

 

 

 

 

 

1.Install the batteries (AAA) into the remote control transmitter. The “HOUSE” icon with room temperature will be displayed.

2.Press the ON/OFF button on the remote. Icons will appear at the same time and acoustic signal is generated if not, move the transmitter closer to the re- ceiver and repeat. If a signal is still not heard, it will be necessary to execute the address setting procedure. Note: There maybe a few seconds delay before the re- ceiver responds. Especially when using the wrought iron faceplate.

3.Fahrenheit - Celsius temperature indicator

It is possible to set the Remote Control transmitter to dis- play the temperatures in either Fahrenheit or Celsius. Use the UP or DOWN button on the transmitter until the cursor (small triangle) is left of the clock icon.

4.From time 0:00 press the LEFT key ten times. The display will show the transmitter address. Use the RIGHT button to toggle from °F to °C and vice versa. The display will show the selected unit of measure. Press the LEFT button to exit this function.

W415-0583 / D / 07.24.07

Image 19 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsCare of Glass VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values Ceptable HT + VT= 10.7 + 6 =16.7VT = 4.2 x 6 = 25.2 ft Since both formulas are met, this vent confi guration is acTOP Vertical Termination TOP Exit Vertical TerminationW415-0583 / D Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Fireplace Vent Connection Using Rigid Vent ComponentsVertical Venting Installation Extended Horizontal AIR Terminal InstallationMobile Home Installation GAS InstallationRestricting Vertical Vents Clearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionFinishing / Servicing Burner Base Removal BOWL, Mesh & Rock ReplacementBattery Replacement Blower ReplacementTurn off the power to the fi replace Turn off the gas valve Fireplace Operation Night Lighttm ReplacementOperation / Maintenance Time OUTFlame Height Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF To Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsFlame Characteristics AdjustmentsMaintenance Pilot Burner AdjustmentConversion KIT Venturi AdjustmentClosing the air shutter Replacements 000 Symptom Problem Test Solution Trouble Shooting GuideStanding Main Pilot goes out while Gas piping is undersizedBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / D