Napoleon Fireplaces GD82NT-T, GD82PT-T manual GAS Installation, Mobile Home Installation

Page 13

6. Remove nails from the shingles, above and to the sides

of the chimney. Place the fl ashing over the air terminal and

slide it underneath the sides and upper edge of the shingles.

Ensure that the air terminal is properly centred within the flash-

ing, giving a 3/4” margin all around. Fasten to the roof. Do NOT

nail through the lower portion of the fl ashing. Make weather-

tight by sealing with caulking. Where possible, cover the sides

and top edges of the fl ashing with roofi ng material.

7. Apply a heavy bead of waterproof caulking 2 inches

above the fl ashing. Slide the storm collar around the air ter-

minal connector and down to the caulking. Tighten to ensure

that a weather-tight seal between the air terminal and the

collar is achieved.

13

GAS INSTALLATION

Proceed once the vent installation is complete.

Note : All gas connections must be contained within

the fireplace when complete.

1.The fi replace is designed to accept a ½” gas supply line. The fireplace is equipped with a ½” manual shut-off valve, and an 18” listed fl exible gas connector.

FIGURE 25

8. Continue adding rigid venting sections, sealing and

securing as above. Attach a 4” collapsed telescopic pipe to

the last section of rigid piping. Secure with screws and seal.

Repeat using a 7” telescopic pipe.

9. Run a bead of high temperature sealant around the

outside of the 4” collar on the fi replace. Pull the adjustable

pipe a minimum of 2” onto the collar. Secure with 3 screws.

Repeat with the 7” telescopic pipe.

10. In the attic, slide the vent pipe collar down to cover up

the open end of the shield and tighten. This will prevent any

materials, such as insulation, from fi lling up the 1” air space

around the pipe.

MOBILE HOME INSTALLATION

2"

8 7/8"

FIGURE 26

2.The access to the gas inlet is located on the right side of the outer shell.

3.The fl ex connector and shut off must all be in the accessible portion of the

replace.

4.When flexing any gas line, support the gas valve so that the lines are not bent.

5.Check for gas leaks by brushing on a soap and water solution. Do not use open flame.

This appliance is certifi ed to be installed as an OEM (Origi- nal Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufac- tured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This ap- pliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance.

RESTRICTING VERTICAL VENTS

FIGURE 27

TOP OF THE

 

FIREBOX

 

RESTRICTOR PLATE

This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

The fi replace is equipped with two 1/4” diameter holes located in the fron left and right corners of the base. For mobile home installations, the fi replace must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure.

Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home.

After moving the mobile home and prior to lighting the fireplace, ensure that the logs are positioned correctly.

This appliance is certifi ed to be installed in an aftermarket permanently located manufactured (mobile) home, where not prohibited by local codes.

FLUE COLLAR

Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional appearance.

The plate has a series of holes to allow for adjustment. Remove the two screws on either side of the exhaust collar inside the fi rebox. Install the plate in the desired set of holes, then replace the screws.

It is recommend to secure in the third set of holes which causes the greatest amount of restriction for vent length between 15 and 30 feet.

W415-0583 / D / 07.24.07

Image 13 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsCare of Glass VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values VT = 4.2 x 6 = 25.2 ft HT + VT= 10.7 + 6 =16.7Since both formulas are met, this vent confi guration is ac CeptableTOP Vertical Termination TOP Exit Vertical TerminationW415-0583 / D Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Vertical Venting Installation Using Rigid Vent ComponentsExtended Horizontal AIR Terminal Installation Fireplace Vent ConnectionMobile Home Installation GAS InstallationRestricting Vertical Vents Clearance to Combustibles FramingElectrical Schematic Hard Wiring ConnectionElectrical Connection Mantle ClearancesFinishing / Servicing Burner Base Removal BOWL, Mesh & Rock ReplacementBattery Replacement Blower ReplacementTurn off the power to the fi replace Turn off the gas valve Operation / Maintenance Night Lighttm ReplacementTime OUT Fireplace OperationFlame Height Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF What to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASMaintenance AdjustmentsPilot Burner Adjustment Flame CharacteristicsConversion KIT Venturi AdjustmentClosing the air shutter Replacements 000 Symptom Problem Test Solution Trouble Shooting GuideStanding Main Pilot goes out while Gas piping is undersizedBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / D