Napoleon Fireplaces GD82PT-T, GD82NT-T manual Hand Held Remote Operations, Flame Height

Page 20

20

TIME OUT

If the appliance is turned on and the Receiver does not receive any command for 24 hours, it automatically turns the appliance and the Remote Control off.

FIREPLACE OPERATION

To operate this fi replace using the remote, the pilot must be running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the auto position.

FIGURE 39

1.Install the batteries (AAA) into the remote control transmitter. The “HOUSE” icon with room temperature will be displayed.

2.Press the ON/OFF button on the remote. Icons will appear at the same time and acoustic signal is generated if not, move the transmitter closer to the re- ceiver and repeat. If a signal is still not heard, it will be necessary to execute the address setting procedure. Note: There maybe a few seconds delay before the receiver responds. Especially when using the wrought iron face- plate.

3.Fahrenheit - Celsius temperature indicatior

It is possible to set the Remote Control transmitter to display the temperatures in either Fahrenheit or Celsius. Use the UP or DOWN button on the transmitter until the cursor (small triangle) is left of the clock icon.

4.From time 0:00 press the LEFT key ten times. The display will show the transmitter address. Use the RIGHT button to toggle from °F to °C and vice versa. The display will show the selected unit of measue. Press the LEFT button to exit this function.

2.FLAME HEIGHT

This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual

ame height until the cursor (small triangle) is to the left of the big fl ame. (Fig. 47) Use the RIGHT or LEFT button to set the desired fl ame height. Six fl ame levels are included, from 1 (minimum) to 6 (maximum). An acoustic signal from the Receiver confi rms the reception of the command.

FIGURE 47

3.AUTOMATIC CHANGE OF FLAME HEIGHT

The system is provided with three automatic sequences to change continuously the fl ame height. Thirty steps compose each sequence with an interval between one step and the other of 5 seconds, for a total duration of 2.5 minutes. At the end the sequence repeats continually until the sequence function is changed to an alternate pattern or turned to off. The Remote Control can select one of the predefi ned se- quences. Use the UP or Down button until the cursor (small triangle) is to the left of the two small fl ames. (Fig. 48)

Use the left or right button to select sequence 1, 2 or 3. When using the sequence function the room thermostat is active.

FIGURE 48

HAND HELD REMOTE OPERATIONS

1.ON / OFF

To turn the fi replace on press the ON / OFF button, the

replace will always light at maximum fl ame setting. Press the ON / OFF button again to turn the fi replace off.

4.ROOM THERMOSTAT

The Remote Control can operate as a room thermostat. To activate this function use the UP and DOWN key until the cursor (small triangle) is left of the thermometer icon. Then use the right of left button to set the desired room temperature. (Fig. 49)

This control system will cycle automatically the appliance on or off to maintain the selected temperature.

W415-0583 / D / 07.24.07

Image 20 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationVenting Lengths & AIR Terminal Locations VentingCare of Glass Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions HT + VT= 10.7 + 6 =16.7 VT = 4.2 x 6 = 25.2 ftSince both formulas are met, this vent confi guration is ac CeptableTOP Exit Vertical Termination TOP Vertical TerminationW415-0583 / D Installation Wall and Ceiling Protection Vertical Installation Horizontal InstallationVertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Using Rigid Vent Components Vertical Venting InstallationExtended Horizontal AIR Terminal Installation Fireplace Vent ConnectionRestricting Vertical Vents GAS InstallationMobile Home Installation Framing Clearance to CombustiblesHard Wiring Connection Electrical SchematicElectrical Connection Mantle ClearancesFinishing / Servicing BOWL, Mesh & Rock Replacement Burner Base RemovalTurn off the power to the fi replace Turn off the gas valve Blower ReplacementBattery Replacement Night Lighttm Replacement Operation / MaintenanceTime OUT Fireplace OperationHand Held Remote Operations Flame HeightFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GASAdjustments MaintenancePilot Burner Adjustment Flame CharacteristicsClosing the air shutter Venturi AdjustmentConversion KIT Replacements 000 Trouble Shooting Guide Symptom Problem Test SolutionBurner is in ‘OFF’ Supply working pressure Position Pilot goes out while Gas piping is undersizedStanding Main Fireplace Service History W415-0583 / D