Napoleon Fireplaces GD82PT-T, GD82NT-T manual Table of Contents

Page 2

2

TABLE of CONTENTS

PG 2-5

INTRODUCTION

19

NIGHT LIGHTTM REPLACEMENT

 

Warranty

 

 

 

Dimensions

19-23

OPERATION / MAINTENANCE

 

General Instructions

 

 

Time Out

 

General Information

 

 

 

Fireplace Operation

 

Care of Glass & Plated Parts

 

 

 

Hand Held Remote Operation

 

 

 

5-9

VENTING

 

Dip Switch Number Chart

 

Vent lengths

 

Operating Instructions

 

 

 

 

Venting Specifi cations

24

ADJUSTMENTS

 

Air Terminal Locations

10-15

INSTALLATION/FRAMING

 

Pilot Burner Adjustment

 

Venturi Adjustment

 

Wall & Ceiling Protection

25

CONVERSION KIT

 

Using Flexible Vent Components

 

 

 

Fireplace Vent Connection

26-27

REPLACEMENTS

 

Using Rigid Vent Components

 

Gas Installation

 

Replacement Parts

 

Restricting Vertical Vents

 

Flexible Vent Kits

 

Framing

 

Terminal Kits

 

Clearance to Combustibles

 

Roof Terminal Kits

 

Mantle Clearances and Enclosures

 

Accessories

15

ELECTRICAL CONNECTION

 

Replacement Parts Diagram

 

 

 

Hard Wiring Connections

28-29

TROUBLE SHOOTING GUIDE

 

Schematic

 

 

16-18

FINISHING / SERVICING

30

SERVICE HISTORY

 

Door Removal

 

 

 

Burner Assembly Removal

31

NOTES

 

Battery Replacement

 

 

Blower Replacement

Bowl, Mesh & Rock Replacement

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

Do not burn wood or other materials in this fi replace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fi replace.

Clothing or other fl ammable material should not be placed on or near the fi replace.

Due to high temperatures, the fi replace should be located out of traffi c and away from furniture and draperies.

Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.

Even after the fi replace is out, the glass and/or screen will remain hot for an extended period of time.

Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the fl oor.

Any safety screen or guard removed for servicing must be replaced prior to operating the fi replace.

It is imperative that the control compartments, burners and circulating blower and its passageway in the fi replace and vent- ing system are kept clean. The fi replace and its venting system should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fi replace area must be kept clear and free from combustible materials, gasoline and other fl ammable vapours and liquids.

Under no circumstances should this fi replace be modifi ed.

This fi replace must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.

Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi re- place and to replace any part of the control system and any gas control which has been under water.

Do not operate the fi replace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person.

Do not strike or slam shut the fi replace glass door.

This fi replace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

Pressure relief doors must be kept closed while the fi replace is operating to prevent exhaust fumes containing carbon mon- oxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause

the surrounding combustible materials to overheat and catch fi re.

Only doors/optional fronts certifi ed with the appliance shall be used.

W415-0583 / D / 07.24.07

Image 2 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationVenting Lengths & AIR Terminal Locations VentingCare of Glass Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions Since both formulas are met, this vent confi guration is ac HT + VT= 10.7 + 6 =16.7VT = 4.2 x 6 = 25.2 ft CeptableTOP Exit Vertical Termination TOP Vertical TerminationW415-0583 / D Installation Wall and Ceiling Protection Vertical Installation Horizontal InstallationVertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Extended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsVertical Venting Installation Fireplace Vent ConnectionRestricting Vertical Vents GAS InstallationMobile Home Installation Framing Clearance to CombustiblesElectrical Connection Hard Wiring ConnectionElectrical Schematic Mantle ClearancesFinishing / Servicing BOWL, Mesh & Rock Replacement Burner Base RemovalTurn off the power to the fi replace Turn off the gas valve Blower ReplacementBattery Replacement Time OUT Night Lighttm ReplacementOperation / Maintenance Fireplace OperationHand Held Remote Operations Flame HeightFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF Lighting Instructions Operating InstructionsWhat to do if YOU Smell GAS To Turn OFF GASPilot Burner Adjustment AdjustmentsMaintenance Flame CharacteristicsClosing the air shutter Venturi AdjustmentConversion KIT Replacements 000 Trouble Shooting Guide Symptom Problem Test SolutionBurner is in ‘OFF’ Supply working pressure Position Pilot goes out while Gas piping is undersizedStanding Main Fireplace Service History W415-0583 / D
Related manuals
Manual 31 pages 39.69 Kb