Napoleon Fireplaces GD82NT-T, GD82PT-T manual Replacements

Page 27

27

REPLACEMENTS

Contact your dealer for questions concerning prices and avail-

1.

MODEL & SERIAL NUMBER OF FIREPLACE

ability of replacement parts. Normally all parts can be ordered

2.

INSTALLATION DATE OF FIREPLACE

through your Napoleon® dealer or distributor.

3.

PART NUMBER

When ordering replacement parts always give the following

4.

DESCRIPTION OF PART

information:

5.

FINISH

FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF

THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR

THE CLAIM.

REPLACEMENT PARTS

#PART NO. DESCRIPTION

1

W135-0275

OUTER ROCKS

2

W135-0304

SINGLE ROCK

3

W135-0277

BOWL

4

GL-655

ROCK SET ASSEMBLY

5

W565-0090

WIRE MESH

6*

W390-0002

DOOR LATCH (EA)

7W725-0047 NATURAL GAS VALVE - MODULATING

7W725-0048 PROPANE GAS VALVE - MODULATING

8*

W455-0019

NATURAL GAS ORIFICE #43

8*

W455-0003

PROPANE GAS ORIFICE #54

9W680-0005 THERMOCOUPLE **

10W240-0005 ELECTRODE C/W LEAD

11W680-0004 THERMOPILE

12W010- 1194 NATURAL GAS PILOT ASSEMBLY

13W010- 1201 PROPANE GAS PILOT ASSEMBLY

14*

W455-0070

NG PILOT INJECTOR

14*

W455-0068

LP PILOT INJECTOR

15*

W385-0334

NAPOLEON® LOGO

16W500-0106 FIRESTOP (2 INCH CLEARANCE)

17W100-0099 BURNER

18

GD 552

BLOWER

19

W660-0041

SPARK SWITCH

20

W660-0046

TRANSMITTER

21

W660-0045

RECEIVER

22W190-0017 DC SPARK UNIT CONTROL

23W300-0086 NIGHT LIGHT GLASS

24W387-0006 NIGHT LIGHT LAMP

25W750-0107 NIGHT LIGHT WIRE

26W290-0080 NIGHT LIGHT LENSE GASKET

27*

W361-0027

INSULATION SLEEVE

28

W225-0171

DOOR

29*

W500-0205

RESTRICTOR

30*

W010-1500

GLASS W/ GASKET

*IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR NAPOLEON®

DEALER.

FLEXIBLE VENT KITS

GD220 (5 FT)

31*

W010-0397

4” FLEXIBLE ALUMINIUM LINER

 

 

- (5 FT) C/W SPACERS

31*

W410-0017

7” FLEXIBLE ALUMINIUM LINER - (5 FT)

GD330 (10 FT)

32*

W010-0300

4” FLEXIBLE ALUMINIUM LINER

 

 

- (10 FT) C/W SPACERS

32*

W410-0018

7” FLEXIBLE ALUMINIUM LINER - (10 FT)

33*

W010-0370

WALL SUPPORT ASSEMBLY

TERMINAL KITS

34

PERISCOPE

 

- GD201

35

WALL TERMINAL KIT

- GD222R

 

 

 

 

ROOF TERMINAL KITS

 

36*

1/12 TO 7/12 PITCH

- GD110

37*

8/12 TO 12/12 PITCH

- GD111

38*

FLAT ROOF

 

- GD112

39

W490-0073

4/7 INNER/OUTER SLEEVE

 

40

W670-0006

4/7 TERMINAL

 

41

W170-0086

STORM COLLAR

 

42

W010-0453

ROOF SUPPORT

 

43W263-0065 / ROOF FLASHING

W263-0066 / ROOF FLASHING

W263-0067 ROOF FLASHING

 

 

ACCESSORIES

44*

W573-0007

HI-TEMP SEALANT

45

GD501

HEAT GUARD

46

GA-566

HOT AIR DISTRIBUTION KIT

47*

GA-72

HOT AIR EXHAUST KIT

48

GA-70

EXTENSION KIT, 5FT FLEX VENT

49*

W010-0370

WALL SUPPORT ASSEMBLY

50*

W175-0001

4” COUPLER

51*

W175-0013

7” COUPLER

52*

W175-0239

CONVERSION KIT - NG TO LP

53*

W175-0240

CONVERSION KIT - LP TO NG

54

RFK82

RECTANGLE FACING KIT

55

AFK82

ARCHED FACING KIT

56*

RFK82WI

WROUGHT IRON FACING KIT

NOTE: Care must be taken when removing and disposing of any broken glass or damaged components. Be sure to vacuum up and broken glass from inside the fi replace before operation.

Installation and repairs must be performed by a qualifi ed installer, service agency or the supplier.

**WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

**WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther- mocouple supplied by Wolf Steel Ltd.

W415-0583 / D / 07.24.07

Image 27 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsVenting Care of GlassVenting Lengths & AIR Terminal Locations TOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values Ceptable HT + VT= 10.7 + 6 =16.7VT = 4.2 x 6 = 25.2 ft Since both formulas are met, this vent confi guration is acTOP Vertical Termination TOP Exit Vertical TerminationW415-0583 / D Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionUsing Flexible Vent Components Horizontal AIR Terminal InstallationVertical AIR Terminal Installation Fireplace Vent Connection Using Rigid Vent ComponentsVertical Venting Installation Extended Horizontal AIR Terminal InstallationGAS Installation Mobile Home InstallationRestricting Vertical Vents Clearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionFinishing / Servicing Burner Base Removal BOWL, Mesh & Rock ReplacementBlower Replacement Battery ReplacementTurn off the power to the fi replace Turn off the gas valve Fireplace Operation Night Lighttm ReplacementOperation / Maintenance Time OUTFlame Height Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF To Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsFlame Characteristics AdjustmentsMaintenance Pilot Burner AdjustmentVenturi Adjustment Conversion KITClosing the air shutter Replacements 000 Symptom Problem Test Solution Trouble Shooting GuidePilot goes out while Gas piping is undersized Standing MainBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / D
Related manuals
Manual 31 pages 39.69 Kb