Napoleon Fireplaces GD82PT-T manual Venturi Adjustment, Conversion KIT, Closing the air shutter

Page 26
Fig. 3

26

VENTURI ADJUSTMENT

Closing the air shutter

Air Shutter Openings

will cause a more yellow

 

 

 

LP

1/2

flame, but can lead to

carboning. Opening the

NG

3/16

 

air shutter will cause a

 

 

 

 

 

 

more blue fl ame, but can

 

 

 

cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established.

3. Remove the glass

door by pulling the two

latch handles located

along the top front edge

forward and then lift the

hook out from the slot

in the door frame, to

release the top of the

door. Next, pivot the

door forward until the

top edge of the door

clears the front of the

fi replace. Grip the sides

BURNER

CONTROL PANEL BASE

CONTROL PANEL

FIGURE 62

WARNING: Failure to position the parts in

of the door & lift the door

out from the retainer

along the bottom. (Fig.

S

EE-THRU

W

I

N

D

OW

BURNER ELECT

BOTTOM BOX (AA Ba

AIR SHUTTER OPENING

accordance with these diagrams or failure to use only parts specifically approved

1)

4. Remove the control

panel cover. (Fig. 2)

CURVED DECORATIVE PANEL

Requir

with this appliance may result in property damage or personal injury.

5.Remove the bowl and rockset exposing the pilot assembly.

6.Using a deep 9/16” socket wrench, remove the main burner orifi ce. A 7/8back-up wrench must be used on the manifold, located below the housing to ensure that the aluminium tubing does not twist or kink. Replace the burner orifi ce supplied using pipe thread compound.

7.Remove the burner hood from the pilot assembly by

pulling vertically. Use a 5/32” allen key to unscrew the injector. Replace the pilot injector with the one supplied. Replace the pilot hood onto the assembly ensuring key position for proper alignment.

PILOT

HOOD

PILOT

INJECTOR

CONVERSION KIT

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly, a fire, explosion or pro- duction of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.

SIT

8. Before replacing the burner assembly, adjust the burner

shutter opening to 1/2” for propane and 1/16” for natural gas.

9. Replace and re-secure the burner assembly, ensuring that the venturi fi ts over the burner orifi ce.

10. To convert the main valve to the desired fuel, follow the instructions

that are supplied with the SIT regulator assembly kit.

11. The conversion data label must be filled out and attached adjacent

to the valve.

12. Turn on the gas supply and check for gas leaks by brushing on

a soap and water solution. Do not use open flame.

13. Refer to page 28 for min and max pressures and instructions

for checking proper pressures. Replace the front portion of the air

1. “CAUTION” Before proceeding with conversion, the gas supply must be shut off prior to disconnecting the electric power.

Fig.1

defl ector and install the logs.

14. Then light the pilot and main burner to ensure that the gas lines

have been purged and that the fi replace is operating properly at

26,000 BTU’s for both fuels.

15. Re assemble the remaining components & turn on the electrical

supply to the fi replace.

2. Remove the optional front by lifting it up and away from the front of the fi replace. (Fig. 1)

Purge all gas lines with the glass door open.

Assure that a continuous flow is at the burner before closing the door.

W415-0583 / D / 07.24.07

Image 26 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationVenting Lengths & AIR Terminal Locations VentingCare of Glass Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions Since both formulas are met, this vent confi guration is ac HT + VT= 10.7 + 6 =16.7VT = 4.2 x 6 = 25.2 ft CeptableTOP Exit Vertical Termination TOP Vertical TerminationW415-0583 / D Installation Wall and Ceiling Protection Vertical Installation Horizontal InstallationVertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Extended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsVertical Venting Installation Fireplace Vent ConnectionRestricting Vertical Vents GAS InstallationMobile Home Installation Framing Clearance to CombustiblesElectrical Connection Hard Wiring ConnectionElectrical Schematic Mantle ClearancesFinishing / Servicing BOWL, Mesh & Rock Replacement Burner Base RemovalTurn off the power to the fi replace Turn off the gas valve Blower ReplacementBattery Replacement Time OUT Night Lighttm ReplacementOperation / Maintenance Fireplace OperationHand Held Remote Operations Flame HeightFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF Lighting Instructions Operating InstructionsWhat to do if YOU Smell GAS To Turn OFF GASPilot Burner Adjustment AdjustmentsMaintenance Flame CharacteristicsClosing the air shutter Venturi AdjustmentConversion KIT Replacements 000 Trouble Shooting Guide Symptom Problem Test SolutionBurner is in ‘OFF’ Supply working pressure Position Pilot goes out while Gas piping is undersizedStanding Main Fireplace Service History W415-0583 / D