XG2600 Hardware Guide | Chapter 2 Installation |
|
|
Installation Requirements
The product is specifically designed for
Check-list
Check the following items.
Check Item | Check Result |
|
|
Nothing is put on the switch.
Vents are not obstructed.
The switch is not located on the table or not stuck on another switch.
The switch is not located under direct sunshine, near heating appliance, under high humidity or in a dusty area..
The switch is not located on unstable places where vibrating, or tilting.
"For Safe Use of the Product" has been thoroughly read Reference (pg.8)
2.1.2Space Requirements
When installing the switch and providing maintenance, ensure the space below is maintained.
Ensuring the Space for Installation (Maintenance) of the Switch
Internal cooling fans of the switch allow the air intake and exhaust performed at both at the Interface Side and Fan Unit Side. Ensure the indicated space below and do not put anything which avoids airflow.
800mm
Back space for the maintenance
rack
300mm or more
Space for the maintenance/ installation
150mm or more
XG2600
90mm or more
800mm
300mm or more
Space for the maintenance/ installation
19" rack Depth
Front space for the maintenance
19" rack Width
28 | Requirements for Installation Environment |