Belkin F1DE216C, F1DE208C, F1DE116C user manual Error Messages and Dialogs

Page 19

P74290ea_F1DExxxC_man.qxd 30-10-2003 11:20 Page 32

USING YOUR SWITCH

Advanced Button

Activating this button will take the user to the advanced option screen.

Disable Viewing

When “Disable Viewing” is checked, only another administrator may view channels occupied by the administrator. This function will be active by default in the OSD by design. For security reasons, admin needs to disable this if need be.

Daisy-Chain this KVM

Checking this box allows Switches set to BANK 00 to communicate with other BANKs in a daisy-chain configuration. This affects front-panel operations, and other operational parameters. Whenever the state of this check box is changed, the following message will be displayed, “This will reset the KVM to change this setting”. If the user selects “OK”, the Switch will immediately reboot in the new configuration. By default, Switches set to BANK 00 are configured as standalone (the check box is cleared).

Steal Control of this Host

This feature allows the KVM administrator to take full control of a host that is currently being used by other users.

Restore Factory Defaults

Selecting this button will reset ALL user-configurable settings (computer names, group names, passwords, etc.) to their default values on all BANKs in the daisy-chain. The user is presented with a confirmation screen before this action is applied.

Note: In a daisy-chain configuration, restoring factory default will cause unpredictable behavior. To resolve this temporary issue, the administrator will have to go back into the Options page, select the “Advanced” button, and check the “daisy-chain this KVM” box after “Restoring Factory Defaults” for BANK 00 to function properly.

USING YOUR SWITCH

Error Messages and Dialogs

From time to time, it will be necessary to display messages to the user indicating errors or requesting simple answers to questions. These pop-up screens use the familiar format of title bar and window body, which contains the text of the message. It includes appropriate response controls such as OK and Cancel buttons, based on the nature of the message.

Login Dialog

The Login dialog is a simple window with radio buttons to select the user, and an edit box for the user to enter a password. If the user is already logged-in, pressing “Cancel” returns the user to his or her current login (or guest, if the account is enabled). If the user is not logged in, and guest is disabled, pressing cancel will close the OSD.

Help Screens

Online help is available within the OSD. Simply press the F1 key, or click on the “?” button on the right side of the title bar.

Banner

The banner, a small window that is displayed to inform the user of the console’s focus, appears as a line of text surrounded by a gray, 3-D frame. It displays the following information:

Group name

Host name

BANK and port in focus

If multiple consoles are viewing the same computer (MultiView Mode), the console with control displays the following banner information:

Viewed by console [console letter]

BANK and port in focus

The view-only console displays the following banner information:

Viewing only, no control

BANK and port in focus

The banner also displays important error messages and important changes in the KVM configuration.

Splash Screen

When you power-on the Switch, a window appears that displays its product name and copyright information. This window remains for several seconds then disappears. Opening the OSD will clear the Splash Screen immediately.

32

33

Image 19
Contents OmniView KVM Switch with Micro-Cabling Technology Introduction Table of ContentsOverview Feature OverviewOmniView Enterprise Quad-Bus Series Daisy-Chain Cable SpecificationsEquipment Requirements Cables OmniView Enterprise Quad-Bus Series Dual-Port KVM CableFront View with Fascia Flipped Down F1DE216C Front View of the Switch F1DE216CBack View of the KVM Switch F1DE208C Front View with Fascia Flipped Down F1DE108CCable Length Recommendations InstallationInstalling the Switch into a Server Rack Standalone Switch InstallationConnecting Computers to the Switch USB Connection Connect the Console Connecting Multiple Switches Daisy-ChainingInstallation Before you begin DIP Switch Configuration ChartExample Powering Up the Systems Example of Daisy-Chain ConfigurationConnecting the Daisy-Chain Cable Connecting the ComputersUsing Your Switch Using the MultiView Feature Selecting a Computer Using Keyboard Hot Key CommandsUsing the AutoScan Function from the Front Panel AutoScan ModeInput and Navigation Features IntelliView OSD FeaturesIntelliView Graphical On-Screen Display Menu Control ID Column MainGroup Column Computer Name Column Scan Column Setup Security User Columns 1, 2, 3, G PasswordsPassword Entry Fields Enable Check BoxesOptions Error Messages and Dialogs Updating Firmware AutoUpdate Firmware Update UtilityInstalling the AutoUpdate application Connecting the computer to the SwitchUpdating Devices via the Web Avoided while the update is in progressUpdating your KVM Manually with a File from a Local Disk Completing a Standalone KVM Firmware Update Completing the Firmware UpdateTroubleshooting Glossary FCC Statement InformationBelkin.com Belkin Corporation P74290Contenu de l’emballage Table DES MatièresPrésentation des fonctions PrésentationPlateformes Configuration Requise CâblesCâbles KVM Double Port OmniView série Entreprise Quad-Bus Systèmes d’exploitationVue avant avec panneau avant incliné F1DE216C Vue avant du Switch F1DE216CVue arrière du switch KVM F1DE208C Vue avant avec panneau incliné F1DE108CInstallation de l’unité dans une baie de serveur Recommandations quant à la longueur des câblesInstallation d’un switch autonome Branchement des ordinateurs sur le switch connexion USB Branchez la console Connexion de plusieurs switches montage en sérieModèles 2x8 et 2x16 seulement Installation Avant de commencer Diagramme de configuration du commutateur DIPPar exemple Branchement des ordinateurs Exemple de configuration en sérieBranchement du câble de montage en série Ajout d’unités supplémentairesMode Statique Idle Utilisation DE Votre SwitchConfiguration autonome Configuration de montage en sérieUtilisation de la fonction MultiView Mode AutoScanSélection d’un ordinateur à l’aide des raccourcis clavier Utilisation de la fonction AutoScan depuis la face avantFonctions d’entrée et de navigation Fonction de l’affichage à l’écran IntelliViewColonne ID PrincipaleColonne Group Groupe Colonne Computer Name Nom de l’ordinateurColonne Scan Balayage La Page de ConfigurationSecurity Sécurité Colonnes d’utilisateurs 1, 2, 3, G Passwords Mots de passeDes options Broadcast Passwords Diffuser les mots de passeDisplay Banner Aff. bannière Messages d’erreur et boîtes de dialogue Mise à jour du microprogramme ’Utilitaire de mise à jour du microprogramme AutoUpdateInstallation de l’application AutoUpdate Branchement de l’ordinateur au switchMise à jour est en cours Mise à jour des périphériques via le WebCes deux paragraphes sont une répétition voir ci-dessus Terminer la mise à jour du microprogramme Dépannage Glossaire Déclaration FCC KVM Switch mit Mikro-Kabeltechnologie Packungsinhalt InhaltsverzeichnisEinführung Einleitung ÜbersichtMerkmale ÜbersichtBetriebssysteme Systemvoraussetzungen KabelOmniView Enterprise Zweifach-KVM-Kabel der Quad-Bus-Serie OmniView Enterprise Kaskadierungskabel derQuad-Bus -erieVorderansicht mit geschlossener Blende F1DE216C Vorderansicht des Switch F1DE216CRückansicht des KVM Switch F1DE208C Vorderansicht mit geschlossener Blende F1DE108CEinfache Installation des Switch Einbau des Switch in einen Server-RackEmpfohlene Kabellängen Computer mit dem Switch verbinden USB Anschließen der Konsole Verbinden mehrerer Switches KaskadierungNur 2x8- und 2x16-Modelle Konfiguration der DIP-Schalter Installation VorbereitungBeispiel Anschließen der Computer Installation weiterer GeräteBeispiel für eine Kaskadierung Schließen Sie das Kaskadierungskabel anVerwenden DES Switches Verwenden der MultiView-Funktion Auswahl eines Computer über TastaturbefehleBedienung der AutoScan-Funktion über das Bedienfeld AutoScan-BetriebIntelliView-Funktionen IntelliView Bildschirm-Menüsystems Das IntelliEingabe- und Navigationsfunktionen Spalte ID Kennung Die HauptseiteSpalte Group Gruppe Spalte Computer Name ComputernameSpalte Scan Scannen Die KonfigurierungsseiteSeite Security Sicherheitseinstellungen Benutzerspalten 1, 2, 3, G Seite Passwords KennwörterDisplay Restricted Ports Gesperrte Ports anzeigen Seite Options OptionenDisplay Banner Display Inactive Ports Inaktive Ports anzeigenFehlermeldungen und Dialoge Schalten Sie den Switch ein Der Firmware-Aktualisierungsdienst AutoUpdate FirmwareInstallieren der Dienstanwendung AutoUpdate Anschließen des Computers an den SwitchVermeiden muss Aktualisieren von Geräten per InternetVerwenden DES Switches Abschließen der Firmware-Aktualisierung Aktualisieren mehrerer KVM Switches KaskadierungFehlerbehebung Glossar FCC-Erklärung Rechtliche HinweiseBelkin Kundendienst P74290ea