Belkin F1DE216C, F1DE208C Cable Length Recommendations, Standalone Switch Installation

Page 7

P74290ea_F1DExxxC_man.qxd 30-10-2003 11:20 Page 8

INSTALLATION

Pre-Configuration

The enclosure of the Switch is designed for desktop or rack-mount configuration. The Switch is rack-mountable in standard 19-inch server racks. Rack-mount hardware is included with these Switches for a sturdy rack installation. Anti-skid feet are included for stable desktop configurations.

Consider the following when deciding where to place the Switch:

Whether or not you intend to use the direct-access port selectors

The lengths of the cables attached to your keyboard, monitor, and mouse

The location of your computers in relation to your console

The lengths of the cables you use to connect your computers to the Switch

The placement of the daisy-chained BANKs in your server room, and the lengths of the cables you use to connect the BANKs in your daisy-chain

Cable Length Recommendations

For PS/2 computers

We recommend that PS/2 cable length be limited to 25 feet for best video performance. Beyond that length, the probability of video degradation increases.

For USB computers

We recommend that USB cable length be limited to 12 feet for best performance.

Installing the Switch into a Server Rack

The Switch includes mounting brackets ideal for installation in 19-inch racks.

Please consider the following before rack-mounting your Switch.

a)Elevated Operating Ambient Temperature – If installed in a closed or multiunit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with manufacturer’s maximum rate ambient temperature.

b)Reduce Air Flow – Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised.

c)Mechanical Loading – Mounting of the equipment in the rack should be such that hazardous condition is not achieved due to uneven mechanical loading.

d)Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit.

INSTALLATION

1.Remove the brackets from the box.

2.Align the bracket with the front of the Switch for flush installation in your rack.

3.Attach the bracket to the side of your Switch with the screws provided.

4.Mount the Switch to the rack rail assembly.

*** Cautions and Warnings ***

Before attempting to connect anything to the Switch or your computer(s), please ensure that all your computer equipment and devices are powered off. Belkin Corporation is not responsible for damage caused by your failure to do so.

Standalone Switch Installation

This section provides complete instructions for the hardware setup of a single Switch.

Connecting Computers to the Switch (PS/2 Connection)

1.Attach the IEC power cable to the power connector located on the rear of the Switch.

Hosts 1 & 2

 

Hosts 3 & 4

 

Hosts 5 & 6

 

Hosts 7 & 8

 

 

 

 

 

 

 

8

9

Image 7
Contents OmniView KVM Switch with Micro-Cabling Technology Introduction Table of ContentsOverview Feature OverviewOmniView Enterprise Quad-Bus Series Daisy-Chain Cable SpecificationsEquipment Requirements Cables OmniView Enterprise Quad-Bus Series Dual-Port KVM CableFront View with Fascia Flipped Down F1DE216C Front View of the Switch F1DE216CBack View of the KVM Switch F1DE208C Front View with Fascia Flipped Down F1DE108CCable Length Recommendations InstallationInstalling the Switch into a Server Rack Standalone Switch InstallationConnecting Computers to the Switch USB Connection Connect the Console Connecting Multiple Switches Daisy-ChainingInstallation Before you begin DIP Switch Configuration ChartExample Powering Up the Systems Example of Daisy-Chain ConfigurationConnecting the Daisy-Chain Cable Connecting the ComputersUsing Your Switch Using the MultiView Feature Selecting a Computer Using Keyboard Hot Key CommandsUsing the AutoScan Function from the Front Panel AutoScan ModeInput and Navigation Features IntelliView OSD FeaturesIntelliView Graphical On-Screen Display Menu Control ID Column MainGroup Column Computer Name ColumnScan Column SetupSecurity User Columns 1, 2, 3, G PasswordsPassword Entry Fields Enable Check BoxesOptions Error Messages and Dialogs Updating Firmware AutoUpdate Firmware Update UtilityInstalling the AutoUpdate application Connecting the computer to the SwitchUpdating Devices via the Web Avoided while the update is in progressUpdating your KVM Manually with a File from a Local Disk Completing a Standalone KVM Firmware Update Completing the Firmware UpdateTroubleshooting Glossary FCC Statement InformationBelkin.com Belkin Corporation P74290Contenu de l’emballage Table DES MatièresPrésentation des fonctions PrésentationPlateformes Configuration Requise CâblesCâbles KVM Double Port OmniView série Entreprise Quad-Bus Systèmes d’exploitationVue avant avec panneau avant incliné F1DE216C Vue avant du Switch F1DE216CVue arrière du switch KVM F1DE208C Vue avant avec panneau incliné F1DE108CInstallation de l’unité dans une baie de serveur Recommandations quant à la longueur des câblesInstallation d’un switch autonome Branchement des ordinateurs sur le switch connexion USB Branchez la console Connexion de plusieurs switches montage en sérieModèles 2x8 et 2x16 seulement Installation Avant de commencer Diagramme de configuration du commutateur DIPPar exemple Branchement des ordinateurs Exemple de configuration en sérieBranchement du câble de montage en série Ajout d’unités supplémentairesMode Statique Idle Utilisation DE Votre SwitchConfiguration autonome Configuration de montage en sérieUtilisation de la fonction MultiView Mode AutoScanSélection d’un ordinateur à l’aide des raccourcis clavier Utilisation de la fonction AutoScan depuis la face avantFonctions d’entrée et de navigation Fonction de l’affichage à l’écran IntelliViewColonne ID PrincipaleColonne Group Groupe Colonne Computer Name Nom de l’ordinateurColonne Scan Balayage La Page de ConfigurationSecurity Sécurité Colonnes d’utilisateurs 1, 2, 3, G Passwords Mots de passeDes options Broadcast Passwords Diffuser les mots de passeDisplay Banner Aff. bannière Messages d’erreur et boîtes de dialogue Mise à jour du microprogramme ’Utilitaire de mise à jour du microprogramme AutoUpdateInstallation de l’application AutoUpdate Branchement de l’ordinateur au switchMise à jour est en cours Mise à jour des périphériques via le WebCes deux paragraphes sont une répétition voir ci-dessus Terminer la mise à jour du microprogramme Dépannage Glossaire Déclaration FCC KVM Switch mit Mikro-Kabeltechnologie Packungsinhalt InhaltsverzeichnisEinführung Einleitung ÜbersichtMerkmale ÜbersichtBetriebssysteme Systemvoraussetzungen KabelOmniView Enterprise Zweifach-KVM-Kabel der Quad-Bus-Serie OmniView Enterprise Kaskadierungskabel derQuad-Bus -erieVorderansicht mit geschlossener Blende F1DE216C Vorderansicht des Switch F1DE216CRückansicht des KVM Switch F1DE208C Vorderansicht mit geschlossener Blende F1DE108CEinfache Installation des Switch Einbau des Switch in einen Server-RackEmpfohlene Kabellängen Computer mit dem Switch verbinden USB Anschließen der Konsole Verbinden mehrerer Switches KaskadierungNur 2x8- und 2x16-Modelle Konfiguration der DIP-Schalter Installation VorbereitungBeispiel Anschließen der Computer Installation weiterer GeräteBeispiel für eine Kaskadierung Schließen Sie das Kaskadierungskabel anVerwenden DES Switches Verwenden der MultiView-Funktion Auswahl eines Computer über TastaturbefehleBedienung der AutoScan-Funktion über das Bedienfeld AutoScan-BetriebIntelliView-Funktionen IntelliView Bildschirm-Menüsystems Das IntelliEingabe- und Navigationsfunktionen Spalte ID Kennung Die HauptseiteSpalte Group Gruppe Spalte Computer Name ComputernameSpalte Scan Scannen Die KonfigurierungsseiteSeite Security Sicherheitseinstellungen Benutzerspalten 1, 2, 3, G Seite Passwords KennwörterDisplay Restricted Ports Gesperrte Ports anzeigen Seite Options OptionenDisplay Banner Display Inactive Ports Inaktive Ports anzeigenFehlermeldungen und Dialoge Schalten Sie den Switch ein Der Firmware-Aktualisierungsdienst AutoUpdate FirmwareInstallieren der Dienstanwendung AutoUpdate Anschließen des Computers an den SwitchVermeiden muss Aktualisieren von Geräten per InternetVerwenden DES Switches Abschließen der Firmware-Aktualisierung Aktualisieren mehrerer KVM Switches KaskadierungFehlerbehebung Glossar FCC-Erklärung Rechtliche HinweiseBelkin Kundendienst P74290ea