Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.
Complete the following steps to install a module:
Note: These instructions assume the BladeCenter unit is connected to power.
1.Read the safety information beginning on page vii and “Installation guidelines” on page 13 through “Handling
2.Remove the acoustic module option, if installed, from the rear of the BladeCenter unit. See “Installing and removing the acoustic module option” on page 21 for instructions.
3.Remove the filler module from the bay.
4.Ensure that the release lever on the module is in the open position (perpendicular to the module).
5.Slide the module into the appropriate module bay until it stops.
6.Push the release lever on the front of the module closed.
7.Attach any cables or cords required by the module. See “Input/output connectors” on page 26 for the location of connectors on the BladeCenter unit. Be sure to route the power cord on a power module through the
8.Make sure the LEDs on the module indicate that it is operating properly. Verify that:
vThe dc power LED and the ac power LED on each power module are lit.
vThe OK LED on the management module is lit.
vThe OK LED on each I/O module is lit.
9.If you have other modules to install, do so now; otherwise, go to step 10.
10.Replace the acoustic module option, if you removed it in step 2.