Device | Suggested action |
The monitor has screen jitter, | If the monitor |
or the screen image is wavy, | the monitor. Magnetic fields around other devices (such as transformers, appliances, |
unreadable, rolling, or | fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable, |
distorted. | rolling, or distorted screen images. If this happens, turn off the monitor. (Moving a |
| color monitor while it is turned on might cause screen discoloration.) Then move the |
| device and the monitor at least 305 mm (12 in.) apart. Turn on the monitor. |
| Notes: | |
| 1. | To prevent diskette drive read/write errors, make sure that the distance between |
|
| the monitor and diskette drive is at least 76 mm (3 in.). |
| 2. | |
| 3. | An enhanced monitor cable with additional shielding is available for the 9521 and |
|
| 9527 monitors. For information about the enhanced monitor cable, contact your |
|
| IBM marketing representative or authorized reseller. |
| If the problem remains, call for service. | |
|
| |
All other symptoms | Troubleshoot the blade server that is the current owner of the keyboard, video, and | |
| monitor. |
Power problems
Device | Suggested action |
|
|
The BladeCenter unit does | v Make sure that the power cables are properly connected to the power modules in |
not start. | the BladeCenter unit. |
| v Make sure that the |
| v Make sure that the LEDs on the power module are on. |
| v If you just installed an option, remove it, and restart the BladeCenter unit. If the |
| BladeCenter unit now starts, you might have installed more options than the power |
| module supports. |
| If the problem remains, call for service. |
|
|
Management module problems
Device | Suggested action |
|
|
Management module does | Call for service. |
not complete changeover to |
|
redundant module on |
|
hardware failure. |
|
|
|
Blower module problems
Device | Suggested action |
|
|
Blower module operates at | Make sure that: |
full speed, with no regulation. | v Both blower modules are functioning (neither has failed). |
| v Each power module is connected to an ac power source. A power module that is |
| not connected to an ac power source creates a |
| and causes the blower modules to operate at full speed. |
| If a blower module has failed, replace the module as soon as possible. |
|
|