The amp-hour setting should be set to a value equal or lower than the actual amp-hour capacity of the system’s battery bank. Using a number that is lower than the actual amp-hour capacity allows the % Battery State-of- Charge meter to provide a more conservative indication for the use of the batteries to avoid excessively discharging them.

Also note the temperature at which the battery capacity is rated. The amp-hour capacity of the batteries decreases at temperatures lower than the rated value.

The amp-hour rating is usually printed on the battery’s label. If the

system contains batteries in parallel, then the amp-hour rating of the parallel batteries is added together (i.e., two 120 amp-hour rated batteries in parallel equals 240 amp hours). The amp-hour capacity of a bank does not increase for series-wired batteries and is equal to the lowest rated battery in the series string. If the amp-hour capacity is not listed on the battery, consult the battery manufacturer or dealer for assistance.

Setting the Amp Hours

1.Press the SELECT button until the AMP-HOURS LED ( Ah ) is illuminated.

2.Press the SELECT and RESET buttons simulataniously until the LED display flashes.

3.Press the RESET button to change the displayed amp hours to a value slightly lower than the system’s total battery amp-hour capacity.

4.Press the SELECT button to accept the new value. The selection range is between 10 (010.) to 2,550 (2.55) Ah.

NOTE: When the flashing display indicates between 010. to 990. (decimal point after the right most digit), read the display directly. When the flashing display indicates between 1.00 to 2.55 (decimal point two places to the left), multiply the reading by 1000 (i.e., a flashing 160. equals 160 amp hours; a flashing 1.60 in the display equals 1,600 amp hours).

© 2001 Xantrex Technology Inc.

15

P/N 973-0012-01-02 Rev.A05/01

 

Image 21
Contents TM500A Trademarks About XantrexDisclaimers Date and RevisionTable of Contents Table of Contents Important Safety Instructions Battery Safety Information Introduction TM500ATM500A TM500A 12/24 Volt Unpacking and InspectionTM500A NS 12/24 Volt TM48 48 VoltPre-Installation InstallationRequired Tools MountingSurface Mounting Communication and Remote Cable Connections Surface Mounting the TM500A Using the AdaptorFlush Mounting Flush Mounting the TM500A Area To Be Cut-OutExtended Length Ground Wire Extended Length InstallationsShunt Connections Deltec Shunt Mounting/Wiring the ShuntShunt Circuit Board and Hardware Mounting Circuit Board to an Existing ShuntConnecting the Shunt Board Circuit DiagramIn-line Fuse Setup ConfigurationRestoring the Factory Defaults Resetting to Factory DefaultsSetting Parameters Setting ParametersSetting Parameters Charge Efficiency % Setting the Charge Efficiency FactorSetting Charger Efficiency Setting the Amp Hours Setting Parameters Amp Hours AhSetting the Amp Hours Step a Setting the Fully-Charged Voltage Level Setting Parameters Charged Indicator SetupSetting the Charged Indicator Voltage Level Step B Switching OFF the Amperage DetectionTurn Amps OFF for Voltage only Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Trigger on Voltage and Time Step B Setting the Time DurationRelay Chargers Taper ChargersThree-stage Chargers Setting Parameters Low-Voltage Indicator Configuring the Low-Voltage AlarmLow-Voltage Indicator Reset Button Indicators and ControlsOperation Buttons Select ButtonIndicators and Controls Basic Meters Meter Selection and LED IndicatorsAvailable Meters % state-of charge Indicators and Controls Ah AMP Hours Power Saving ModeMode Indicator LEDs BHI High Battery Voltage Indicators and Controls Data MonitorsBLO Low Battery Voltage DSF Days Since FullTo access the Data Monitor Function Reminders and Indicators To configure this functionAmp-Hour Reminder To configure this alarm Reminders and Indicators Low-Voltage IndicatorReminders and Indicators Charged Indicator To reset the Charged LEDResetting the Charged Indicator Symptom Possible Cause Solution TroubleshootingService Information Specifications SpecificationsLimited Warranty Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.