Xantrex Technology TM500A manual Indicators and Controls Ah AMP Hours, Power Saving Mode

Page 33

4.0 OPERATION

Indicators and Controls (continued)

Ah (AMP HOURS)

When this indicator is illuminated, the LED display shows the total amp hours used since the last time the amp-hour meter was reset. The range is from ±0.00 to ±167,000 amp hours. When the decimal point flashes, multiply the reading by 1000 (i.e., 111. = 111,000). This meter automatically resets to zero approximately one minute after the CHARGED LED remains ON solid (stops flashing).

Battery Voltage Indicator

%State-of- Charge Indicator

Full

Amperage Indicator (Load or Charge)

Amp Hours

(Receiving or

Used) Indicator

Figure 4-3

Mode Indicator LEDs

Power Saving Mode

The TM500A can be put into a low-power/power-saving mode by repeat- edly pressing the SELECT button until the display goes blank. In this mode, none of the LED indicators illuminate. The power consumption of the unit is reduced from 32 mA maximum to approximately 18 mA. Pressing the SELECT button again exits the power-saving mode.

© 2001 Xantrex Technology Inc.

27

P/N 973-0012-01-02 Rev. A 05/01

 

Image 33
Contents TM500A Trademarks About XantrexDisclaimers Date and RevisionTable of Contents Table of Contents Important Safety Instructions Battery Safety Information Introduction TM500ATM500A TM500A 12/24 Volt Unpacking and InspectionTM500A NS 12/24 Volt TM48 48 VoltPre-Installation InstallationRequired Tools MountingSurface Mounting Communication and Remote Cable Connections Surface Mounting the TM500A Using the AdaptorFlush Mounting Flush Mounting the TM500A Area To Be Cut-OutExtended Length Ground Wire Extended Length InstallationsShunt Connections Deltec Shunt Mounting/Wiring the ShuntShunt Circuit Board and Hardware Mounting Circuit Board to an Existing ShuntConnecting the Shunt Board Circuit DiagramIn-line Fuse Setup ConfigurationRestoring the Factory Defaults Resetting to Factory DefaultsSetting Parameters Setting ParametersSetting Parameters Charge Efficiency % Setting the Charge Efficiency FactorSetting Charger Efficiency Setting the Amp Hours Setting Parameters Amp Hours AhSetting the Amp Hours Step a Setting the Fully-Charged Voltage Level Setting Parameters Charged Indicator SetupSetting the Charged Indicator Voltage Level Step B Switching OFF the Amperage DetectionTurn Amps OFF for Voltage only Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Trigger on Voltage and Time Step B Setting the Time DurationRelay Chargers Taper ChargersThree-stage Chargers Setting Parameters Low-Voltage Indicator Configuring the Low-Voltage AlarmLow-Voltage Indicator Reset Button Indicators and ControlsOperation Buttons Select ButtonIndicators and Controls Basic Meters Meter Selection and LED IndicatorsAvailable Meters % state-of charge Indicators and Controls Ah AMP Hours Power Saving ModeMode Indicator LEDs BHI High Battery Voltage Indicators and Controls Data MonitorsBLO Low Battery Voltage DSF Days Since FullTo access the Data Monitor Function Reminders and Indicators To configure this functionAmp-Hour Reminder To configure this alarm Reminders and Indicators Low-Voltage IndicatorReminders and Indicators Charged Indicator To reset the Charged LEDResetting the Charged Indicator Symptom Possible Cause Solution TroubleshootingService Information Specifications SpecificationsLimited Warranty Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.