Xantrex Technology TM500A manual Trigger on Voltage and Amperage

Page 25

3.0 CONFIGURATION

Setting Parameters (continued)

CHARGED Indicator Setup (continued)

Trigger on Voltage and Amperage

When this mode is selected, the CHARGED indicator LED illuminates when the voltage reaches the programmed level (Step A) and the amperage decreases to the value set in Step B.

As batteries charge, their voltage slowly increases and the charging current decreases. Setting these parameters allows the CHARGED indicator LED to illuminate when specified conditions are met. However, if a suffi- ciently high amperage is being drawn from DC loads during charging, the meter detects this current, and it prevents the TM500A from illuminating the CHARGED indicator LED. To set the meter to illuminate the CHARGED LED, the amperage trigger level must be increased to account for the additional

DC loads.

NOTE: The batteries may not be fully charged if DC loads are in the system and the current level is increased.

To determine the appropriate fully charged amperage for the system, divide the battery bank amp-hour capacity by 20. For example; if the battery bank’s amp-hour rating equals 880 amp hours, divide this value by 20 for an amperage setting of 44 amps.

Step A Setting the Fully-Charged Voltage Level

1A. Press the SELECT button until the Voltage LED ( V ) is illuminated.

2A. Press the SELECT and RESET buttons simulataniously until the LED display flashes.

3A. Press the RESET button to change the displayed voltage to the desired fully charged voltage level:

For a 12 VDC system, set this voltage between 14.3–14.9 volts for lead-acid batteries.

For a 24 VDC system, set this voltage between 28.6–29.6 volts for lead-acid batteries.

For a 48 VDC system, set this voltage between 57.2–59.2 volts for lead-acid batteries.

Refer to the battery manufacturer’s recommendation for other types of batteries.

4A. Press the SELECT button to accept the new value. The selection range is between 10 to 64.9 VDC.

© 2001 Xantrex Technology Inc.

19

P/N 973-0012-01-02 Rev.A05/01

 

Image 25
Contents TM500A Trademarks About XantrexDisclaimers Date and RevisionTable of Contents Table of Contents Important Safety Instructions Battery Safety Information TM500A IntroductionTM500A TM500A 12/24 Volt Unpacking and InspectionTM500A NS 12/24 Volt TM48 48 VoltPre-Installation InstallationRequired Tools MountingSurface Mounting Communication and Remote Cable Connections Surface Mounting the TM500A Using the AdaptorFlush Mounting Flush Mounting the TM500A Area To Be Cut-OutExtended Length Ground Wire Extended Length InstallationsShunt Connections Deltec Shunt Mounting/Wiring the ShuntShunt Circuit Board and Hardware Mounting Circuit Board to an Existing ShuntCircuit Diagram Connecting the Shunt BoardIn-line Fuse Setup ConfigurationRestoring the Factory Defaults Resetting to Factory DefaultsSetting Parameters Setting ParametersSetting the Charge Efficiency Factor Setting Parameters Charge Efficiency %Setting Charger Efficiency Setting the Amp Hours Setting Parameters Amp Hours AhSetting the Amp Hours Step a Setting the Fully-Charged Voltage Level Setting Parameters Charged Indicator SetupStep B Switching OFF the Amperage Detection Setting the Charged Indicator Voltage LevelTurn Amps OFF for Voltage only Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Trigger on Voltage and Time Step B Setting the Time DurationTaper Chargers Relay ChargersThree-stage Chargers Configuring the Low-Voltage Alarm Setting Parameters Low-Voltage IndicatorLow-Voltage Indicator Reset Button Indicators and ControlsOperation Buttons Select ButtonMeter Selection and LED Indicators Indicators and Controls Basic MetersAvailable Meters % state-of charge Power Saving Mode Indicators and Controls Ah AMP HoursMode Indicator LEDs BHI High Battery Voltage Indicators and Controls Data MonitorsBLO Low Battery Voltage DSF Days Since FullTo access the Data Monitor Function To configure this function Reminders and IndicatorsAmp-Hour Reminder To configure this alarm Reminders and Indicators Low-Voltage IndicatorTo reset the Charged LED Reminders and Indicators Charged IndicatorResetting the Charged Indicator Symptom Possible Cause Solution TroubleshootingService Information Specifications SpecificationsLimited Warranty Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.