Xantrex Technology TM500A manual Setting the Charged Indicator Voltage Level

Page 24

3.0 CONFIGURATION

Setting Parameters (continued)

CHARGED Indicator Setup (continued)

14.4

1A

4A

2A

3A

 

 

Set Voltage Level

Voltage LED

Illuminates to Indicate the Voltage Function is Selected

Figure 3-5

Setting the CHARGED Indicator Voltage Level

The fully-charged voltage parameters are now set. To allow the voltage only setting to trigger the fully-charged LED, the amperage setting must be switched OFF.

Step B Switching OFF the Amperage Detection

1B. Press the SELECT button until the Amperage LED ( A ) is illuminated.

2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes.

3B. Press the RESET button until the display indicates OFF.

4B. Press SELECT button to accept.

The TM500A is now setup to trigger the CHARGED indicator LED () when the voltage level equals or exceeds the value programmed in Step A. When this voltage parameter is met, the CHARGED indicator LED flashes approximately every four seconds.

NOTE: The CHARGED indicator remains ON (solid) even when the batteries are discharging, until reset.

OFF

1B

4B

Set Amps to

OFF

Amperage LED

Illuminates to Indicate

the Amperage

Function is Selected

2B

3B

Figure 3-6

Turn Amps OFF for VOLTAGE ONLY Detection

18

© 2001 Xantrex Technology Inc.

P/N 973-0012-01-02 Rev.A05/01

Image 24
Contents TM500A About Xantrex TrademarksDisclaimers Date and RevisionTable of Contents Table of Contents Important Safety Instructions Battery Safety Information Introduction TM500ATM500A Unpacking and Inspection TM500A 12/24 VoltTM500A NS 12/24 Volt TM48 48 VoltInstallation Pre-InstallationRequired Tools MountingSurface Mounting Surface Mounting the TM500A Using the Adaptor Communication and Remote Cable ConnectionsFlush Mounting Area To Be Cut-Out Flush Mounting the TM500AExtended Length Installations Extended Length Ground WireDeltec Shunt Mounting/Wiring the Shunt Shunt ConnectionsMounting Circuit Board to an Existing Shunt Shunt Circuit Board and HardwareConnecting the Shunt Board Circuit DiagramIn-line Fuse Configuration SetupRestoring the Factory Defaults Resetting to Factory DefaultsSetting Parameters Setting ParametersSetting Parameters Charge Efficiency % Setting the Charge Efficiency FactorSetting Charger Efficiency Setting Parameters Amp Hours Ah Setting the Amp HoursSetting the Amp Hours Setting Parameters Charged Indicator Setup Step a Setting the Fully-Charged Voltage LevelSetting the Charged Indicator Voltage Level Step B Switching OFF the Amperage DetectionTurn Amps OFF for Voltage only Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Step B Setting the Time Duration Trigger on Voltage and TimeRelay Chargers Taper ChargersThree-stage Chargers Setting Parameters Low-Voltage Indicator Configuring the Low-Voltage AlarmLow-Voltage Indicator Indicators and Controls Reset ButtonOperation Buttons Select ButtonIndicators and Controls Basic Meters Meter Selection and LED IndicatorsAvailable Meters % state-of charge Indicators and Controls Ah AMP Hours Power Saving ModeMode Indicator LEDs Indicators and Controls Data Monitors BHI High Battery VoltageBLO Low Battery Voltage DSF Days Since FullTo access the Data Monitor Function Reminders and Indicators To configure this functionAmp-Hour Reminder Reminders and Indicators Low-Voltage Indicator To configure this alarmReminders and Indicators Charged Indicator To reset the Charged LEDResetting the Charged Indicator Troubleshooting Symptom Possible Cause SolutionService Information Specifications SpecificationsWarranty Limited Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.