Xantrex Technology TM500A manual Troubleshooting, Symptom Possible Cause Solution

Page 39

5.0 TROUBLESHOOTING

Symptom

Possible Cause

Solution

LED in INVERTER ON/OFF

J2 plug not plugged into

Plug cable into TM500A and

switch does not light.

TM500A or the inverter.

Inverter's RC4/RC8 remote

 

 

control jack.

 

Inverter does not have a

The inverter remote control

 

compatable Jack.

only operates on models

 

 

equipped with an RC4/RC8

 

 

remote control input.

 

 

 

Voltage displayed on

The TM500A voltage is

Reconfigure the TM500A for

meters is not correct.

configured above 35.0 volts

the correct system voltage

 

for a 12- or 24-volt system.

(see Section 3,

 

 

Configuration, Charged

 

The TM500A voltage is

Indicator Set-up).

 

configured below 35.0 volts

 

 

for a 48-volt system.

 

 

 

 

Battery State-of-Charge

Amp-hour setting is too low.

Reconfigure the amp hours to

displays "FULL" when

 

the correct setting - Battery

voltage is low.

 

bank size (see Section 3,

 

 

Configuration, Setting

 

 

Parameters, Amp Hours).

 

 

 

bLO displays a voltage of

The bLO meter was not

Reconfigure the Low-Voltage

00.0.

configured during set-up, or

Indicator (bLO) for the correct

 

after being disconnected

low-battery voltage (see

 

from the shunt.

Section 3, Configuration,

 

 

Setting Parameters, Low-

 

 

Voltage Indicator).

 

 

 

CHARGED LED continues

VOLTAGE ONLY

Reconfigure the CHARGED

to flash even though the

configuration for the

voltage to an appropriate

current flow is negative

Charged Indicator Setup

value (i.e., 12.6 V for a

(battery discharging)

may be set too low.

12-volt system ), (see Section

continuously for one minute.

 

3, Configuration, Setting

 

 

Parameters, Charged

 

 

Indicator Setup).

 

 

The CHARGED indicator

 

 

must be manually reset to turn

 

 

it OFF.

 

 

 

 

 

973-0012-D-001A

© 2001 Xantrex Technology Inc.

33

P/N 973-0012-01-02 Rev.A05/01

 

Image 39
Contents TM500A Date and Revision About XantrexTrademarks DisclaimersTable of Contents Table of Contents Important Safety Instructions Battery Safety Information Introduction TM500ATM500A TM48 48 Volt Unpacking and InspectionTM500A 12/24 Volt TM500A NS 12/24 VoltMounting InstallationPre-Installation Required ToolsSurface Mounting Communication and Remote Cable Connections Surface Mounting the TM500A Using the AdaptorFlush Mounting Flush Mounting the TM500A Area To Be Cut-OutExtended Length Ground Wire Extended Length InstallationsShunt Connections Deltec Shunt Mounting/Wiring the ShuntShunt Circuit Board and Hardware Mounting Circuit Board to an Existing ShuntConnecting the Shunt Board Circuit DiagramIn-line Fuse Resetting to Factory Defaults ConfigurationSetup Restoring the Factory DefaultsSetting Parameters Setting ParametersSetting Parameters Charge Efficiency % Setting the Charge Efficiency FactorSetting Charger Efficiency Setting the Amp Hours Setting Parameters Amp Hours AhSetting the Amp Hours Step a Setting the Fully-Charged Voltage Level Setting Parameters Charged Indicator SetupSetting the Charged Indicator Voltage Level Step B Switching OFF the Amperage DetectionTurn Amps OFF for Voltage only Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Trigger on Voltage and Time Step B Setting the Time DurationRelay Chargers Taper ChargersThree-stage Chargers Setting Parameters Low-Voltage Indicator Configuring the Low-Voltage AlarmLow-Voltage Indicator Buttons Select Button Indicators and ControlsReset Button OperationIndicators and Controls Basic Meters Meter Selection and LED IndicatorsAvailable Meters % state-of charge Indicators and Controls Ah AMP Hours Power Saving ModeMode Indicator LEDs DSF Days Since Full Indicators and Controls Data MonitorsBHI High Battery Voltage BLO Low Battery VoltageTo access the Data Monitor Function Reminders and Indicators To configure this functionAmp-Hour Reminder To configure this alarm Reminders and Indicators Low-Voltage IndicatorReminders and Indicators Charged Indicator To reset the Charged LEDResetting the Charged Indicator Symptom Possible Cause Solution TroubleshootingService Information Specifications SpecificationsLimited Warranty Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.