Xantrex Technology TM500A manual Trigger on Voltage and Amperage

Page 26

3.0 CONFIGURATION

Setting Parameters (continued)

CHARGED Indicator Setup (continued)

Set Voltage Level

14.4

Voltage LED

Illuminates to Indicate

1Athe Voltage Function is Selected

4A

2A

3A

Figure 3-7

Setting the CHARGED Indicator Voltage Level

Step B Setting the Amperage Trigger Level

1B. Press the SELECT button until the Amperage LED ( A ) is illuminated.

2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes.

3B. Press the RESET button until the display indicates the desired amperage.

4B. Press SELECT button to accept.

The selectable amperage values are from 1 to 99 amps.

The TM500A is now setup to trigger the CHARGED indicator LED () when the voltage level equals or exceeds the value programmed in Step A and the amperage level falls below the value programmed in Step B. When these parameters are met, the CHARGED indicator LED flashes approximately every four seconds. Whenever the current goes negative (discharge) the timer resets to zero. The CHARGED indicator must be manually reset to turn it OFF.

 

 

Set Amperage

1B

44A

Amperage LED

Illuminates to Indicate the

 

 

Amperage Function is

4B

 

 

2B

3B

Figure 3-8

Trigger on Voltage and Amperage

20

© 2001 Xantrex Technology Inc.

P/N 973-0012-01-02 Rev.A05/01

Image 26
Contents TM500A Disclaimers About XantrexTrademarks Date and RevisionTable of Contents Table of Contents Important Safety Instructions Battery Safety Information TM500A IntroductionTM500A TM500A NS 12/24 Volt Unpacking and InspectionTM500A 12/24 Volt TM48 48 VoltRequired Tools InstallationPre-Installation MountingSurface Mounting Surface Mounting the TM500A Using the Adaptor Communication and Remote Cable ConnectionsFlush Mounting Area To Be Cut-Out Flush Mounting the TM500AExtended Length Installations Extended Length Ground WireDeltec Shunt Mounting/Wiring the Shunt Shunt ConnectionsMounting Circuit Board to an Existing Shunt Shunt Circuit Board and HardwareIn-line Fuse Connecting the Shunt BoardCircuit Diagram Restoring the Factory Defaults ConfigurationSetup Resetting to Factory DefaultsSetting Parameters Setting ParametersSetting Charger Efficiency Setting Parameters Charge Efficiency %Setting the Charge Efficiency Factor Setting Parameters Amp Hours Ah Setting the Amp HoursSetting the Amp Hours Setting Parameters Charged Indicator Setup Step a Setting the Fully-Charged Voltage LevelTurn Amps OFF for Voltage only Detection Setting the Charged Indicator Voltage LevelStep B Switching OFF the Amperage Detection Trigger on Voltage and Amperage Trigger on Voltage and Amperage Trigger on Voltage and Time Step B Setting the Time Duration Trigger on Voltage and TimeThree-stage Chargers Relay ChargersTaper Chargers Low-Voltage Indicator Setting Parameters Low-Voltage IndicatorConfiguring the Low-Voltage Alarm Operation Indicators and ControlsReset Button Buttons Select ButtonAvailable Meters % state-of charge Indicators and Controls Basic MetersMeter Selection and LED Indicators Mode Indicator LEDs Indicators and Controls Ah AMP HoursPower Saving Mode BLO Low Battery Voltage Indicators and Controls Data MonitorsBHI High Battery Voltage DSF Days Since FullTo access the Data Monitor Function Amp-Hour Reminder Reminders and IndicatorsTo configure this function Reminders and Indicators Low-Voltage Indicator To configure this alarmResetting the Charged Indicator Reminders and Indicators Charged IndicatorTo reset the Charged LED Troubleshooting Symptom Possible Cause SolutionService Information Specifications SpecificationsWarranty Limited Warranty

TM500A specifications

Xantrex Technology is renowned for its innovative power solutions, and the TM500A is a standout model in its extensive product lineup. This advanced power inverter is engineered to meet the needs of both industrial applications and residential systems, providing users with reliable and efficient power conversion.

One of the main features of the TM500A is its advanced inverter technology, which allows for high efficiency and performance. With an efficiency rating often exceeding 90%, the TM500A minimizes energy loss during the conversion process. This makes it an ideal choice for renewable energy systems, such as solar and wind, by maximizing the amount of usable power delivered to connected devices. The inverter is capable of converting DC power into high-quality AC power, suitable for a wide range of appliances and electronics.

The TM500A is designed with versatility in mind. It supports various input voltage systems, allowing it to be used in a multitude of setups. This flexibility is further enhanced by its ability to operate in both grid-tied and off-grid configurations, opening up possibilities for diverse applications. Whether in a residential setting powering home appliances or in industrial applications supporting heavy machinery, the TM500A adapts to customer needs.

Another characteristic that sets the TM500A apart is its robust safety features. This inverter is equipped with multiple layers of protection, including overload, short circuit, and over-temperature safeguards. These safety measures ensure that both the device and the connected load are protected from potential damage, providing peace of mind to users.

The TM500A also boasts user-friendly interfaces, including LED indicators and diagnostic features that make monitoring performance straightforward. This ease of use is complemented by a compact and lightweight design, making installation and integration into existing systems straightforward.

Finally, Xantrex's commitment to quality is evident in the TM500A's construction, which utilizes durable materials suitable for demanding environments. Overall, the Xantrex TM500A stands as a reliable, efficient, and versatile power conversion solution that meets the evolving demands of users across various sectors. Its combination of advanced technology, safety, and user-centric design makes it a top choice for anyone needing dependable power solutions.